background image

 

set  temperature  value;  the  mode  duration 
time  edition  window  will  be  displayed.  After 
setting  the  required  duration  and  confirming 
by  pushing  the  button,  the  Party  operation 
mode  is  activated;  in  this  mode,  the 
temperature is set to a preset duration. 
Note:  Time  will  be  counted  by  full  hours.  It 
means  that  the  first  hour  will  not  be  a  full 
hour - it will be a number of minutes left to a 
current full hour. 
For  example,  if  the  manual  mode  is  set  to 
17:45  for  a  duration  of  4  hours,  a  real 
duration of the party mode will be 3h 15 min. 
When  a  preset  time  elapses,  the  regulator 
switches  to  a  previous  mode.  In  the  main 
window,  in  a  place  for  displaying  operation 
mode, a glass   icon is displayed. 

7.6.7

 

Holiday mode 

Holiday mode enables to replace the existing 
temperature  setting  for  a  period  of  1  to  99 
days  with  a  constant  temperature.  This 
function  is  particularly  useful  in  case  of 
holiday departure: 
In  order  to  activate  this  mode,  enter  the 
MENU and select: 

Operation Mode 

 Holiday  

The preset room temperature edition window 
will  be  displayed.  Set  the  required 
temperature  by  turning  the  button  right  or 
left. Push the button to confirm and save the 
set  temperature  value.  Next,  the  Holiday 
mode  duration  time  edition  window  will  be 
displayed. After setting the required duration 
and  confirming  by  pushing  the  button,  the 
Holiday  operation  mode  is  activated;  in  this 
mode,  the  temperature  is  set  to  a  preset 
duration. 
Note:  Time  will  be  counted  by  full  days.  It 
means that the first day will not be a full day 
- it will be a number of hours left to a current 
full day. 
For  example,  if  the  manual  mode  is  set  to 
17:45  for  a  duration  of  14  days,  a  real 
duration of the Holiday mode will be 13 days 
6 hours and 15 minutes. 
When  a  preset  time  elapses,  the  regulator 
switches  to  a  previous  mode.  In  the  main 
window,  in  a  place  for  displaying  operation 

mode, a suitcase 

 icon is displayed. 

7.6.8

 

Anti-freeze mode 

In  this  mode,  the  regulator  works  with 
constant  preset  temperature,  set  in  the 
following parameter:  

MENU 

  Temperature  Settings 

  Anti-

freeze temperature

 

In the main window, in a place for displaying 

operation  mode,  a  snowflake 

  icon  is 

displayed. 
Selecting the anti-freeze mode in thermostat 
1 will set the hot utility water temperature in 
the ecoMAX boiler regulato

r to 8°C.

 

7.7

 

Profiles 

The  ecoSTER200  room  panel  enables 
programming  four  profiles  of  schedules.  The 
following  set  of  parameters  is  recorded  for 
each profile: 

 

schedule for all weekdays 

 

night temperature (economic) 

 

day temperature (comfort) 

 

anti-freeze temperature 

 

hysteresis 

Profile  changing  mechanism  is  very  useful  if 
there  is  a  need  of  cyclical  changes  in 
schedule;  for  example  when  user  works  on 
various  shifts.  Then,  by  selecting  a  profile, 
you  can  rapidly  switch  between  several 
programmed  schedules  without  a  necessity 
of editing them. 

7.8

 

Schedule 

Regulator can be programmed in 7-day cycle 
with  an  accuracy  of  0,5  hour.  Therefore, 
there  is  a  possibility  of  48  temperature 
changes per day. 
Regulator enables programming two levels of 
temperature:  day  (comfort)  and  night 
(economic).  Regulator  enables  programming 
various  time  zones  individually  for  each 
weekday. 

7.8.1

 

Programming schedules 

In  order  to  program  a  schedule  for  a 
particular  thermostat,  display  the  main 
screen  of  this  thermostat  (pt.  7.4)  and 
select: 

MENU 

 Schedule 

 

Then, choose a weekday for which you want 
to  establish  or  modify  a  schedule.  After 
selecting  a  weekday,  a  window  for  editing  a 
schedule is displayed. 

Summary of Contents for ecoSTER 200

Page 1: ...Room panel ecoSTER 200 HARDWARE VERSION 2 FOR ECOMAX CONTROLLERS OPERATION AND MAINTENANCE MANUAL ISSUE_EN 1 1 APPLICABLE TO SOFTWARE v10 XX XXX 11 2015...

Page 2: ......

Page 3: ...U 8 7 11 SETTINGS 8 7 11 1 Weather sensor 8 7 11 2 Thermostat settings 9 7 11 3 Hysteresis 9 7 11 4 Temperature correction 9 7 11 5 Language change 9 7 11 6 Sound alarm 9 7 11 7 Clock settings 9 7 11...

Page 4: ...trol It can be used in household and similar facilities as well as in slightly industrialized facilities 3 Information about documentation The ecoSTER200 room panel manual is a supplement for the corr...

Page 5: ...l operation is easy and intuitive When the panel displays main window turn the button right or left in order to change displayed main window 1 thermostat 2 thermostat 3 boiler If temperature sensors o...

Page 6: ...ration and confirming by pushing the button the Output operation mode is activated in this mode the economic temperature is set to a preset duration Note Time will be counted by full hours It means th...

Page 7: ...a duration of 14 days a real duration of the Holiday mode will be 13 days 6 hours and 15 minutes When a preset time elapses the regulator switches to a previous mode In the main window in a place for...

Page 8: ...temperature is set in MENU Temperature settings Day temperature Preset anti freeze temperature is set in MENU Temperature settings Anti freeze temperature 7 10 ecoMAX boiler regulator menu In order t...

Page 9: ...der to set time and date select MENU Settings Clock According to set date the device will automatically set an appropriate weekday The ecoSTER200 panel is equipped with a system clock which is indepen...

Page 10: ...bear any responsibility for damages caused by failure to observe this manual 8 5 Instructions for assembly Open the casing as shown on the figure below Drill holes in a wall If a wall is made of brick...

Page 11: ...tton on this terminal with a flat screwdriver inserting the cable and releasing the button Below are the wiring scheme thermostats with room sensors 2 and 3 type CT7 and the way VCC panel power module...

Page 12: ...12 8 6 2 Connection to ecoMAXX800 R3 T3 and ecoMAX800 P3 D3 8 6 3 Connection to ecoMAX850 P1...

Page 13: ...13 8 6 4 Connection to ecoMAX850 P2 R2 D2 8 6 5 Connection to ecoMAX860 P1 P2 D1 D2...

Page 14: ...In order to guarantee a maximum operation efficiency of the regulator follow the recommendations concerning a place of sensor assembly 1 Sensors should be assembled on a height app 1 5 m over the floo...

Page 15: ......

Page 16: ...ul Wsp lna 19 Ignatki 16 001 Kleosin Poland phone 48 85 749 70 00 fax 48 85 749 70 14 plum plum pl www plum pl www plumelectronics eu...

Reviews: