PX-65CS External Drive
SCSI ID Number
Please see description at the top of page 15. It is also applicable to the external drive.
Factory Setting of Dial and DIP Switches
Caution:
Turn the drive’s power OFF before changing the setting of the dial or DIP
switches.
The SCSI ID number of the PX-65CS is determined by the position of the
pointer on the SCSI ID rotary dial. The drive should arrive with its SCSI
ID set to 2. The rotary dial and DIP switches are set by the factory as
shown below:
Changing the SCSI ID
Using the blade of a screwdriver, rotate the dial’s arrow to a different SCSI ID number.
Changing DIP Switch Settings
Use a screwdriver, pen or paper clip to push the DIP switches to an OFF or ON setting.
Other Switch/Jumper Settings----PX-63CS/PX-65CS
The remaining switches (external drives) and jumpers (internal drives) are:
Parity
Leave this ON. The parity check provided by the ON setting enhances the
reliablility of the SCSI bus. Set to OFF only if your computer system or SCSI
controller specifically requests that parity be disabled.
TEST
SCSI ID
BLOCK
(OFF) O
(ON) l
TERM
PRTY
EJECT
CHAPTER 6 ---- Drive Switch/Jumper/Dial Settings
16
PX-63CS/PX-65CS OPERATION MANUAL