TECHNICAL SUPPORT: (909) 259-6001
ACTP715
25
Installation: Accessory Connections
Solenoid Connection
The solenoid power connection must be
provided an external power source. This will
prevent damage to the battery in the event of
a line power failure.
Guard Station
This will control the gate operator to Open,
Stop, and Close the gate. The switches for
Open and Close must be normally open
type. The switch for Stop must be normally
close type. They all can be using the same
common ground. The control switch box
should be within sight of the gate, out of
reach of children, and away from moving
parts of the gate.
If no guard station or STOP switch is
installed, a jumper must be inserted between
“STOP(NC)” and “GND” pins.
OPEN
STOP
GND
STOP
OPEN
CLOSE
CLOSE
ACCESSORY CONNECTIONS (continued):
ACTP715 Manual_Layout 1 11/4/2014 3:53 PM Page 27