background image

 

Setting Up the Poly Medialign Single Display System

 Poly, Inc.

27

 

s

Attach the cover panel support brackets using four M6 × 12 mm screws. Use the top slots on the 

upper bracket. Use the bottom slots on the lower bracket. 

t

Place the EagleEye Director II power adapter inside the channel of the lower rail of the upper 

horizontal frame. Locate it to the left of the left wall mount bracket. Apply a ferrite bead to the end 

of the coaxial cable that will connect to the camera base. Run the coaxial cable along the 

horizontal support rail over to the left V-rail. 

u

Connect a 1M C13-C14 cable to the power adapter. Route it down behind the speaker bracket 

and rails and connect it to the PDU.

v

Route the mini-HDCI end of the EagleEye Director II camera cable through the codec mounting 

bracket, behind the speaker bracket and support frames up to the horizontal support rail. Run it 

along the horizontal support rail to the left V-rail.

w

Route the 3.5mm end of the EagleEye Director II camera audio cable through the codec mounting 

bracket, behind the speaker bracket and support frames up to the horizontal support rail. Run it 

along the horizontal support rail to the left V-rail.

4

Continue the installation.

If you have a 65” display, refer to 

Set Up the Poly Medialign 65 System

 to continue the installation.

If you have a 75” display, refer to 

Set Up the Poly Medialign 75 System

 to continue the installation.

If you have an 86” display, refer to 

Set Up the Poly Medialign 86 System

 to continue the 

installation.

(4) M6 × 12 mm SCREW 
1601-68586-001

(2) COVER PANEL 
SUPPORT BRACKET 
1342-85984-001

Summary of Contents for Poly Medialign 65

Page 1: ...roducts or services go to Polycom Support Plantronics Inc Poly formerly Plantronics and Polycom 345 Encinal Street Santa Cruz California 95060 2020 Plantronics Inc All rights reserved Poly the propeller design and the Poly logo are trademarks of Plantronics Inc All other trademarks are the property of their respective owners Poly Medialign ...

Page 2: ... the Poly Medialign Single Display System 11 Set Up the Poly Medialign Single Display Frame 11 Set Up the Poly Medialign 65 System 28 Set Up the Poly Medialign 75 System 41 Set Up the Poly Medialign 86 System 53 Setting Up the Poly Medialign Dual Display System 62 Set Up the Poly Medialign 65D System 62 Set Up the Poly Medialign 75D System 92 Set Up the Poly Medialign 86D System 125 Appendix Regul...

Page 3: ...udes a component reference list Polycom G7500 Administrator Guide which provides information about how to upgrade and configure the Polycom G7500 software configure features and maintain systems Polycom G7500 Release Notes which lists the features and limitations of the G7500 system Polycom RealPresence Group Series Administrator Guide which provides information about how to upgrade and configure ...

Page 4: ...oly support personnel and participate in developer and support forums You can find the latest information on hardware software and partner solutions topics share ideas and solve problems with your colleagues The Polycom Partner Network are industry leaders who natively integrate the Poly standards based RealPresence Platform with their customers current UC infrastructures making it easy for you to...

Page 5: ...before you begin the physical installation of the Medialign system in the room Installation Toolkit Installation Sequence Overview Pre Installation Tasks Single Display Medialign Systems The Medialign single system contains a single frame that supports all configurations panels with four different color options and single 65 75 or 86 displays ...

Page 6: ...Installation Overview Poly Inc 6 Poly Medialign 65 system with single 65 display ...

Page 7: ...Installation Overview Poly Inc 7 Dual Display Medialign Systems The Medialign dual display system contains dual 65 75 or 86 displays Poly Medialign 65D system with dual 65 displays ...

Page 8: ...09 Fantastik Top Job or Mr Clean Screen cleaner such as Klear Screen KS HDK HD Cleaning Kit Plasma and LCD Screen Cleaner or equivalent Installation Sequence Overview When assembling a Medialign system you usually assemble the equipment in the order listed in this section However the installation sequence may vary due to factors such as room configuration or limited space to store the equipment du...

Page 9: ...leEye Director II base to camera bracket 2 Connect camera cables 3 Mount camera base on the frame 4 Complete the EagleEye Director II assembly Cable the System Power On Devices 1 Ensure all cables and electrical connections are complete 2 Dress out cables 3 Turn power on for all devices 4 Verify functionality Attach Covers 1 Attach optional riser cover s 2 Attach cover panel 3 Attach speaker cover...

Page 10: ... diagrams for the correct connections area Medialign Single System Connections Area Medialign 65D System Connections Area Medialign 75D System Connections Area Medialign 86D System Connections Area 2 Make sure that you are familiar with the customer s protocols and procedures for security and safety 3 When unpacking do the following a Review the packing slip including the list of spare parts b Che...

Page 11: ...ame used with either a 65 75 or 86 display Before installation unpack and take inventory of all parts to make sure you have everything If you don t call support for missing item s Medialign Components Note The accessory kit shipped with the single display includes the hardware to install two displays Retain the extra hardware in case you install a second display in the future Item Part Number Qty ...

Page 12: ...1 65 Display Mount Bracket or 75 86 Display Mount Bracket 1342 85955 001 1342 85956 001 1 2 M8 20mm Screw 1601 52713 001 8 EagleEye Director II with 2 EagleEye IV 12 Cameras 7230 69420 001 1 65 Top Camera Plate 1342 85954 001 1 EagleEye Director II 75 Camera Mount Bracket 1342 86062 001 1 EagleEye Director II 86 Camera Mount Bracket 1342 86063 001 1 6 Riser Cover Optional 2345 85968 001 1 12 Riser...

Page 13: ...rength can result in damage to the equipment voiding the warranty and causing possible serious personal injury The installer is responsible for conforming to all applicable building codes and local requirements Also ensure that the wall does not have vibrations that could cause the mounted camera to shake more likely to be seen when the camera is zoomed in You can feel the vibration in a wall by l...

Page 14: ...attach the horizontal support rail 1081 10 mm 42 56 in from the floor using eight wall anchors appropriate for your wall type not supplied Use the upper and lower holes in the rail 1081 10mm 42 56in 698 50mm 27 50in FLOOR WALL CENTER LINE OF UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 15: ...Medialign system higher than the standard height you can add a 6 or 12 riser With a 6 riser attach the horizontal support rail 1219 48 mm 48 01 in from the floor using eight wall anchors 1219 48mm 48 01in 698 50mm 27 50in CENTER LINE OF UNIT WALL FLOOR HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 16: ... 16 With a 12 riser Medialign 65 and Medialign 75 systems only attach the horizontal support rail 1371 88 mm 54 01 in from the floor using eight wall anchors 1371 88mm 54 01in 698 50mm 27 50in WALL CENTER LINE OF UNIT FLOOR HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 17: ...e floor with the feet toward the wall where you plan to anchor the frame Space them approximately 1350 mm 53 in apart Orient the rails face down open side up b Screw the leveling feet out until the lower edges of the feet extend 34 mm 1 5 16 in beyond the end of the V rail 1350 mm 53 in Open Side Up Open Side Up 34 mm 1 5 16 in ...

Page 18: ...ling feet from the V rails and install them in the risers Screw them in to the risers until the lower edges of the feet extend 34 mm 1 5 16 in beyond the end of the riser Slide the risers on the V rails and attach them using two M6 12 mm screws per riser 2 M6 x 12mm SCREW 1601 68586 001 34 mm 1 5 16 in ...

Page 19: ...holes circled in red in the next figure Orient the top frame with the large screw holes up away from the wall Orient the lower frame with the large screw holes down toward the wall Attach the frames to the V rails using four M10 25 mm screws per frame e Raise the frame assembly and lean it against the wall HORIZONTAL FRAME 2350 85976 001 FRAME V RAIL 2350 85975 001 FRAME V RAIL 2350 85975 001 8 M1...

Page 20: ... screws per bracket g Center the frame assembly on the horizontal support rail Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the V rails from the wall as required 2 WALL MOUNT BRACKET 1342 85958 001 4 M6 12 mm SCREW 1601 68586 001 ...

Page 21: ...ntal support rail by driving two self tapping screws through each wall mount bracket Double check for plumb and level Caution Wear safety glasses when installing the self tapping hex screws FLOOR WALL CENTER LINE OF UNIT 4 12 24 X 1 25 mm SELF TAP HEX SCREW 1601 52879 001 WALL MOUNT BRACKET 1342 85958 001 ...

Page 22: ... screws supplied with the speakers Orient the speakers so that the tweeters are toward the outside of the frame j Partially thread in two M6 12 mm flanged button screws in the lower locations on the inside of the V rails Leave about half of the thread exposed 2 SPEAKER 2565 84879 001 4 M6 12 mm SCREW 1601 68586 001 2 M6 12 mm SCREW 1601 68586 001 ...

Page 23: ...ots of the speakers and bracket assembly over the screws and swing the assembly in place l Attach the RCA cables to the speakers Route the connectors behind the speaker bracket and through the opening in the bracket Connect the 3 cable to the left speaker and the 10 cable to the right ...

Page 24: ...et assembly to the V rails by installing two more M6 12 mm screws in the top slots of the bracket Tighten all four screws n Install the PDU on the top rail of the lower support frame using two M4 8 mm screws 2 M6 12 mm SCREW 1601 68586 001 PDU 1583 52876 008 2 M4 x 8 mm SCREW 1601 42846 001 ...

Page 25: ... the below image q Attach the codec to the codec mounting bracket using two M3 8 mm thumb screws Poly Medialign Model P019 100 240V AC 6A 50 60 Hz Polycom Netherlands BV Skorpius 171 2132 LR Hoofddorp The Netherlands Medialign 65 Medialign 65D Installed Product Model Number Medialign 75 Medialign 75D Medialign 86 Medialign 86D CODEC MOUNT BRACKET 1342 85957 001 2 M3 8 mm KNURLED THUMB SCREW 1601 8...

Page 26: ...ialign Single Display System Poly Inc 26 r Install the codec mounting bracket assembly on the upper rail of the lower horizontal frame Slide the upper portion of the bracket behind the upper rail and then rotate it into place ...

Page 27: ...ute the mini HDCI end of the EagleEye Director II camera cable through the codec mounting bracket behind the speaker bracket and support frames up to the horizontal support rail Run it along the horizontal support rail to the left V rail w Route the 3 5mm end of the EagleEye Director II camera audio cable through the codec mounting bracket behind the speaker bracket and support frames up to the ho...

Page 28: ... set up the Poly Medialign 65 system with a single 65 display To set up the Medialign 65 system 1 Mount the 65 display a Attach the display mount bracket to the 65 display using four M6 12 mm screws Caution Two people are required to lift the display 65 DISPLAY DISPLAY MOUNT BRACKET 1342 85955 001 4 M6 12 mm SCREW 1601 68586 001 ...

Page 29: ...ng Up the Poly Medialign Single Display System Poly Inc 29 b Partially install two M6 12 mm screws into the outside top of each V rail Leave about half of the threads exposed 4 M6 12 mm SCREW 1601 68586 001 ...

Page 30: ...Setting Up the Poly Medialign Single Display System Poly Inc 30 c Hang the display on the frame Secure it using two M8 20 mm screws 2 M8 20 mm SCREW 1601 52713 001 ...

Page 31: ...cket sliding it over the four M6 12 mm screws previously installed Secure it by tightening all screws 2 Assemble the EagleEye Director II a Following the supplied instructions assemble the microphone column to the EagleEye Director II base Do not install the cameras yet DISPLAY NOT SHOWN FOR CLARITY ...

Page 32: ...EagleEye Director II accessory kit c Pull the HDCI camera audio and camera power cables up and behind the top frame support bracket Connect them to the EagleEye Director II base Tuck the power cable ferrite bead inside the cavity beneath the EEDII base TOP CAMERA PLATE 1342 85954 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTOR II EAGLEEYE DIRECTOR II 7230 69420 001 ...

Page 33: ...to complete the EagleEye Director II assembly 3 Cable the Medialign 65 system a Connect the HDCI cable to the codec b Connect the 3 5mm to 2x RCA F Y adapter cable to the codec audio out c Connect the camera audio cable RCA M connectors to the Y adapter red to red and white to white d Connect the RCA cable for the right speaker to the camera audio cable red RCA F e Connect the RCA cable for the le...

Page 34: ...o the codec and connect it k Connect a 1M C13 C14 cable to the codec power adapter Route it up behind the frame and connect it to the PDU l Connect the C14 C5 adapter to the display Connect a 1M C13 C14 cable to the C14 C5 adapter Route it down and connect to the PDU m Connect the mains cable to the wall outlet Route it behind the frame and connect it to the PDU n Connect the network cable to the ...

Page 35: ...Setting Up the Poly Medialign Single Display System Poly Inc 35 5 Attach the optional riser covers If you installed the 6 risers attach the 6 riser cover with magnets 6 RISER COVER 2345 85968 001 ...

Page 36: ...Setting Up the Poly Medialign Single Display System Poly Inc 36 If you installed the 12 risers attach the 12 metal riser cover with magnets 12 RISER COVER 2345 85969 001 ...

Page 37: ...Setting Up the Poly Medialign Single Display System Poly Inc 37 6 Attach the cover panel by hooking it onto the support brackets COVER PANEL 2352 48053 X00 ...

Page 38: ...Setting Up the Poly Medialign Single Display System Poly Inc 38 7 Attach the speaker cover with magnets SPEAKER COVER 2345 85967 001 ...

Page 39: ...Setting Up the Poly Medialign Single Display System Poly Inc 39 8 Attach the two side covers with magnets 2 SIDE COVER 2352 85971 001 ...

Page 40: ...40 9 Attach the magnetic Poly logo in the center of the speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the front cover panel 5 08 cm 2 in from the left and top edges OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 41: ...cket Align the fifth hole from the top of the brackets with the upper fixing points on the display b Remove the lower handles from the display Store them carefully for future use CAUTION Three people are required to lift the display Due to the weight of the 75 display 64 kg 141 10 lbs and the lift height required on a frame with 12 risers installation of the 75 display on a frame with 12 risers mu...

Page 42: ...em Poly Inc 42 c Partially install two M6 12 mm screws into the outside top of each V rail Leave about half of the threads exposed Note You may prefer to connect the 1M C13 C14 power cable to the display before mounting 4 M6 12 mm SCREW 1601 68586 001 ...

Page 43: ...ign Single Display System Poly Inc 43 d Hang the 75 display centered on the frame and secure with two M8 20 mm screws e Confirm that the frame and display are level Adjust leveling feet if needed 2 M8 20 mm SCREW 1601 52713 001 ...

Page 44: ...ame support bracket sliding it over the four M6 12 mm screws previously installed Secure it by tightening all screws 2 Assemble the EagleEye Director II a Following the supplied instructions assemble the microphone column to the EagleEye Director II base Do not install the cameras yet ...

Page 45: ...he EagleEye Director II accessory kit c Pull the HDCI camera audio and camera power cables up and behind the top frame support bracket Connect them to the EagleEye Director II base Strain relieve the power cable near the camera base if necessary EAGLEEYE DIRECTOR II 7230 69420 001 CAMERA MOUNT BRACKET 1342 86062 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTOR II ...

Page 46: ...he codec audio out c Connect the camera audio cable RCA M connectors to the Y adapter red to red and white to white d Connect the RCA cable for the right speaker to the camera audio cable red RCA F e Connect the RCA cable for the left speaker to the camera audio cable white RCA F f Apply a ferrite bead to one end of the 2M HDMI cable Connect that end of the cable to the display HDMI 1 input Connec...

Page 47: ...e codec power adapter Route it up behind the frame and connect it to the PDU m Connect a 1M C13 C14 cable to the display Route it down and connect to the PDU n Connect the mains cable to the wall outlet Route it behind the frame and connect it to the PDU o Connect the network cable to the network port Route it behind the frame and connect it to the codec network port p Connect the microphone cable...

Page 48: ...Setting Up the Poly Medialign Single Display System Poly Inc 48 5 Attach the optional riser covers If you installed the 6 riser attach the 6 riser cover with magnets 6 RISER COVER 2345 85968 001 ...

Page 49: ...Setting Up the Poly Medialign Single Display System Poly Inc 49 If you installed the 12 riser attach the 12 riser cover with magnets 12 RISER COVER 2345 85969 001 ...

Page 50: ...Setting Up the Poly Medialign Single Display System Poly Inc 50 6 Attach the cover panel by hooking it onto the support brackets COVER PANEL 2352 48053 X00 ...

Page 51: ...Setting Up the Poly Medialign Single Display System Poly Inc 51 7 Attach the speaker cover with magnets SPEAKER COVER 2345 85967 001 ...

Page 52: ...e displays and attach the two side covers with magnets 9 Attach the magnetic Poly logo in the center of the speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the front cover panel 5 08 cm 2 in from the left and top edges 2 SIDE COVER 2352 85971 001 OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 53: ... Mount the 86 display a Attach two display brackets to the 86 display using three M8 20 mm screws per bracket Align the second hole from the top of the brackets with the upper fixing points on the display b Remove the lower handles from the display Store them carefully for future use Caution Three people may be required to lift the display 86 DISPLAY 6 M8 20 mm SCREW 1601 52713 001 DISPLAY BRACKET...

Page 54: ...Hang the display centered on the upper horizontal frame and secure it using two M8 20 mm screws People sitting in front of the system should be at least 8 ft away due to the camera angle when the camera is mounted on top of the display 2 M8 X 20mm SCREW 1601 52713 001 ...

Page 55: ...ach the EagleEye Director II base to the camera mount bracket using the screws supplied in the EagleEye Director II accessory kit f Pull the HDCI camera audio and camera power cables up and connect them to the EagleEye Director II base Strain relieve the power cable near the camera base if necessary EAGLEEYE DIRECTOR II DISPLAY MOUNT BRACKET 1342 86063 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTO...

Page 56: ...t the HDCI cable to the codec b Connect the 3 5mm to 2x RCA F Y adapter cable to the codec audio out c Connect the camera audio cable RCA M connectors to the Y adapter red to red and white to white d Connect the RCA cable for the right speaker to the camera audio cable red RCA F e Connect the RCA cable for the left speaker to the camera audio cable white RCA F f Apply a ferrite bead to one end of ...

Page 57: ...e codec power adapter Route it up behind the frame and connect it to the PDU l Connect a 1M C13 C14 cable to the display Route it down and connect to the PDU m Connect the mains cable to the wall outlet Route it behind the frame and connect it to the PDU n Connect the network cable to the network port Route it behind the frame and connect it to the codec network port o Connect the microphone cable...

Page 58: ...Setting Up the Poly Medialign Single Display System Poly Inc 58 4 If you installed the 6 riser attach the 6 riser cover with magnets 6 RISER COVER 2345 85968 001 ...

Page 59: ...Setting Up the Poly Medialign Single Display System Poly Inc 59 5 Attach the cover panel by hooking it onto the support brackets COVER PANEL 2352 48053 X00 ...

Page 60: ...Setting Up the Poly Medialign Single Display System Poly Inc 60 6 Attach the speaker cover with magnets SPEAKER COVER 2345 85967 001 ...

Page 61: ...es and attach the two side covers with magnets 8 Attach the magnetic Poly logo in the center of the speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the front cover panel 5 08 cm 2 in from the left and top edges 2 SIDE COVER 2352 85971 001 OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 62: ...e inventory of all parts to make sure you have everything If you don t call support for missing item s Medialign 65D Components Item Part Number Qty Horizontal Support Rail 1354 84599 001 2 V Rail Frame 2350 85975 001 4 Top Frame Support Bracket 1342 85953 001 2 M6 12mm Screw 1601 68586 001 60 Horizontal Frame 2350 85976 001 4 M10 25mm Screw 1601 67617 002 16 Speaker Mount Bracket 1342 85952 001 2...

Page 63: ...umb Screw 1601 85974 001 2 65 Display Varies by region 2 Display Mount Bracket 1342 85955 001 2 M8 20mm Screw 1601 52713 001 4 EagleEye Director II with 2 EagleEye IV 12 Cameras 7230 69420 001 1 Top Camera Plate 1342 85954 001 2 6 Riser Cover Optional 2345 85968 001 2 12 Riser Cover Optional 2345 85969 001 2 Cover Panel Support Bracket 1342 85984 001 4 Cover Panel 2352 48053 100 Apple 2352 48053 4...

Page 64: ...e serious personal injury The installer is responsible for conforming to all applicable building codes and local requirements Also ensure that the wall does not have vibrations that could cause the mounted camera to shake more likely to be seen when the camera is zoomed in You can feel the vibration in a wall by lightly placing your hand on the wall 613 5 mm 24 1 8 347 2 mm 13 5 8 Connections 9 Co...

Page 65: ...56 in from the floor using eight wall anchors per rail appropriate for your wall type not supplied Use the upper and lower holes in the rail You must anchor to a minimum of three studs per rail 62 60mm 2 46in 1081 10mm 42 56in 31 30mm 1 23in 1428 30mm 56 23in FLOOR WALL CENTER LINE OF DUAL UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 66: ...ight you can add a 6 or 12 riser With a 6 riser attach the horizontal support rails 1219 48 mm 48 01 in from the floor using eight wall anchors per rail appropriate for your wall type not supplied 62 60mm 2 46in 1219 48mm 48 01in 31 30mm 1 23in 1428 30mm 56 23in FLOOR WALL CENTER LINE OF DUAL UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 67: ...ot supplied 3 Assemble the left frame a Place two vertical rails V rails on the floor with the feet toward the wall where you plan to anchor the frame Space them approximately 1350 mm 53 in apart Orient the rails face down open side up 62 60mm 2 46in 1371 88mm 54 01in 31 30mm 1 23in 1428 30mm 56 23in FLOOR WALL CENTER LINE OF DUAL UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 1350 mm 53 in Open Side...

Page 68: ...r riser d Place two horizontal frames between the V rails Orient them so that the faces with screw holes are toward the floor and the vertical straps are up One rail edge of each frame has small screw holes and the other has large screw holes Orient the top frame with the large screw holes up away from the wall Orient the lower frame with the large screw holes down toward the wall Attach the frame...

Page 69: ...outside top of each V rail Leave about half of the threads exposed f Install the top frame support bracket sliding it over the four M6 12 mm screws previously installed Secure it by tightening all screws 4 Repeat step 3 for the right frame 4 M6 12 mm SCREW 1601 68586 001 TOP FRAME SUPPORT BRACKET 1342 85953 001 ...

Page 70: ...embly using two M6 12 mm screws per bracket c Locate the left frame assembly on the left horizontal support rail The right hand V rail is approximately 19 mm 11 16 in away from the system center line Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the v rails from th...

Page 71: ...g screws through each wall mount bracket Double check for plumb and level e Raise the right frame assembly and lean it against the wall Caution Wear safety glasses when installing the self tapping hex screws FLOOR WALL CENTER LINE OF UNIT 19 mm 11 16 in 4 12 24 X 1 25 mm SELF TAP HEX SCREW 1601 52879 001 WALL MOUNT BRACKET 1342 85958 001 19 mm 11 16 in ...

Page 72: ...ssembly on the right horizontal support rail The distance between the frames is 38 mm 1 5 in Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the V rails from the wall as required Be sure to level between the two frame assemblies as well 2 WALL MOUNT BRACKET 1342 8595...

Page 73: ...right frame as required to align the screw holes i With the joiners attached secure the right frame assembly to the horizontal support rail by driving two self tapping screws through each wall mount bracket Double check for level and plumb 2 65 DUAL JOINER BRACKET 1342 85962 001 4 M6 x 12mm SCREW 1601 68586 001 8 SELF TAPPING SCREW 1601 52879 001 ...

Page 74: ...s head screws supplied with the speakers Orient the speakers so that the tweeters are toward the outside 19 mm 75 in WALL FLOOR CENTER LINE OF DUAL UNIT 2 65 DUAL JOINER BRACKET 1342 85962 001 4 M6 x 12mm SCREW 1601 68586 001 8 SELF TAP HEX SCREW 1601 52879 001 19 mm 75 in 38 mm 1 5 in 2 SPEAKER 2565 84879 001 4 M6 12 mm SCREW 1601 68586 001 BACK ...

Page 75: ...dialign Dual Display System Poly Inc 75 k Partially thread in four M6 12 mm flanged button screws in the lower locations on the insides of the V rails Leave about half of the thread exposed 4 M6 X 12 mm SCREW 1601 68586 001 ...

Page 76: ...t assemblies over the screws and swing the assembly in place The speakers are toward the outsides of the frames m Attach the RCA cables to the speakers Route the connectors behind the speaker bracket and through the opening in the bracket Connect the 3 cable to the left speaker and the 10 cable to the right ...

Page 77: ...ies to the V rails by installing four more M6 12 mm screws in the top slots of the brackets Tighten all eight screws o Install the PDU on the top rail of the left lower support frame using two M4 8 mm Phillips screws 4 M6 12 mm SCREW 1601 68586 001 PDU 1583 52876 008 2 M4 x 8 mm SCREW 1601 42846 001 ...

Page 78: ...the below image r Attach the codec to the codec mounting bracket using two M3 8 mm thumb screws Poly Medialign Model P019 100 240V AC 6A 50 60 Hz Polycom Netherlands BV Skorpius 171 2132 LR Hoofddorp The Netherlands Medialign 65 Medialign 65D Installed Product Model Number Medialign 75 Medialign 75D Medialign 86 Medialign 86D CODEC MOUNT BRACKET 1342 85957 001 2 M3 8 mm KNURLED THUMB SCREW 1601 85...

Page 79: ...racket assembly on the upper rail of the lower horizontal frame Slide the upper portion of the bracket behind the upper rail and then rotate it into place 2 M3 x 8mm KNURLED THUMB SCREW 1601 85974 001 CODEC MOUNT BRACKET 1342 85957 001 2 M4 x 8mm SCREW 1601 42846 001 POWER STRIP 1583 52876 008 ...

Page 80: ...support rail over to the left V rail v Connect a 1M C13 C14 cable to the power adapter Route it down behind the speaker bracket and rails and connect it to the PDU w Route the mini HDCI end of the EagleEye Director II camera cable through the codec mounting bracket behind the speaker bracket and support frames up to the horizontal support rail Run it along the horizontal support rail to the left V...

Page 81: ...lays using four M6 12 mm screws per display b Hang the displays on the upper rails of the horizontal frames Locate them so they are centered on the frames touching each other at the center line and so that holes and threaded inserts align 65 DISPLAY DISPLAY MOUNT BRACKET 1342 85955 001 4 M6 12 mm SCREW 1601 68586 001 ...

Page 82: ...ws per display In order to align the displays where they come together you may have to make minor leveling adjustments to the frames c Following the supplied instructions assemble the microphone column to the EagleEye Director II base Do not install the cameras yet 4 M8 X 20mm SCREW 1601 52713 001 ...

Page 83: ...ing the four screws supplied in the EagleEye Director II accessory kit e Pull the HDCI camera audio and camera power cables up and behind the top frame support bracket Connect them to the EagleEye Director II base TOP CAMERA PLATE 1342 85954 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTOR II EAGLEEYE DIRECTOR II 7230 69420 001 ...

Page 84: ... attach the EagleEye Director II bracket assembly to the top frame support bracket using four M6 12 mm screws g Refer to the Polycom EagleEye Director II Setup Sheet to complete the EagleEye Director II assembly 4 M6 12 mm SCREW 1601 68586 001 TOP FRAME SUPPORT BRACKET 1342 85953 001 FRAME ASSEMBLY AND DISPLAY NOT SHOWN ...

Page 85: ...n 65D system a Connect the HDCI cable to the codec b Connect the 3 5 mm to 2x RCA F Y adapter cable to the codec audio out c Connect the camera audio cable RCA M connectors to the Y adapter red to red and white to white d Connect the RCA cable for the right speaker to the camera audio cable red RCA F 4 M6 x 12mm SCREW 1601 68586 001 TOP CAMERA PLATE 1342 85954 001 ...

Page 86: ...codec power adapter in the lower rail of the lower horizontal frame below the codec Route the cable up to the codec and connect it l Connect a 1M C13 C14 cable to the codec power adapter Route it up behind the frame and connect it to the PDU m Connect the C14 C5 adapters to the displays n Connect a 1M C13 C14 cable to the left display C14 C5 adapter Route it down and connect to the PDU o Connect t...

Page 87: ...Setting Up the Poly Medialign Dual Display System Poly Inc 87 9 Attach the optional riser covers If you installed the 6 risers attach the 6 riser cover with magnets 2 6 RISER COVER 2345 85968 001 ...

Page 88: ...Setting Up the Poly Medialign Dual Display System Poly Inc 88 If you installed the 12 risers attach the 12 riser cover with magnets 2 12 RISER COVER 2345 85969 001 ...

Page 89: ...Setting Up the Poly Medialign Dual Display System Poly Inc 89 10 Attach the cover panels by hooking them onto the support brackets 2 COVER PANEL 2352 48053 X00 ...

Page 90: ...Setting Up the Poly Medialign Dual Display System Poly Inc 90 11 Attach the two speaker covers with magnets 2 SPEAKER COVER 2345 85967 001 ...

Page 91: ...ets 13 Attach the magnetic Poly logo in the center of the left speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the left front cover panel 5 08 cm 2 in from the left and top edges 2 SIDE COVER 2352 85971 001 OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 92: ...2350 85976 001 4 M10 25 mm Screw 1601 67617 002 16 Speaker Mount Bracket 1342 85952 001 2 6 Riser Optional 1342 85959 001 4 12 Riser Optional 1342 85961 001 4 Speaker 2565 84879 001 2 75 Dual Joiner Bracket 1342 85966 001 2 Cable Clip 1661 12703 004 2 M5 10 mm Screw 1601 67756 001 2 Wall Mount Bracket 1342 85958 001 4 12 24 1 25 mm Self tapping Hex Screw 1601 52879 001 8 Power Distribution Unit PD...

Page 93: ...Camera Mount Bracket 1342 86062 001 1 M3 8 mm Knurled Thumb Screw 1601 85974 001 2 6 Riser Cover Optional 2345 85968 001 2 12 Riser Cover Optional 2345 85969 001 2 Cover Panel Support Bracket 1342 85984 001 4 Cover Panel 2352 48053 100 Apple 2352 48053 400 Black 2352 48053 500 White 2352 48053 600 Slate Gray 2 Speaker Cover 2345 85967 001 2 Side Cover 2352 85971 001 2 Side Cover Short 2352 85973 0...

Page 94: ...ble serious personal injury The installer is responsible for conforming to all applicable building codes and local requirements Also ensure that the wall does not have vibrations that could cause the mounted camera to shake more likely to be seen when the camera is zoomed in You can feel the vibration in a wall by lightly placing your hand on the wall 613 5 mm 24 1 8 347 2 mm 13 5 8 Connections 9 ...

Page 95: ...upport rails 1081 10 mm 42 56 in from the floor using eight wall anchors per rail appropriate for your wall type not supplied Use the upper and lower holes in the rail You must anchor to a minimum of three studs per rail 1081 10mm 42 56in 339 79mm 13 38in 169 89mm 6 69in FLOOR WALL CENTER LINE OF DUAL UNIT ...

Page 96: ...4 01 in from the floor using eight wall anchors CAUTION Due to the weight of the 75 display 64 kg 141 10 lbs without packaging and the lift height required on a frame with 12 risers installation of the 75 display must be done by professional installers People sitting in front of the system should be at least 2 44 m 8 ft away due to the camera angle when the camera is mounted on top of the display ...

Page 97: ...Setting Up the Poly Medialign Dual Display System Poly Inc 97 339 79mm 13 38in FLOOR WALL CENTER LINE OF DUAL UNIT 169 89mm 6 689in 1371 88mm 54 01in ...

Page 98: ...the floor with the feet toward the wall where you plan to anchor the frame Space them approximately 1350 mm 53 in apart Orient the rails face down open side up b Screw the leveling feet out until the lower edges of the feet extend 34 mm 1 5 16 beyond the end of the v rail 1350 mm 53 in Open Side Up Open Side Up 34 mm 1 5 16 in ...

Page 99: ...eling feet from the V rails and install them in the risers Screw them in to the risers until the lower edges of the feet extend 34 mm 1 5 16 beyond the end of the riser Slide the risers on the V rails and attach them using two M6 12mm screws per riser 2 M6 x 12mm SCREW 1601 68586 001 34 mm 1 5 16 in ...

Page 100: ...oles up away from the wall Orient the lower frame with the large screw holes down toward the wall Attach the frames to the V rails using four M10 25mm screws per frame 4 Repeat step 3 for the right frame 5 Raise the frame assemblies and continue the installation a Raise the left frame assembly and lean it against the wall HORIZONTAL FRAME 2350 85976 001 FRAME V RAIL 2350 85975 001 FRAME V RAIL 235...

Page 101: ...ly on the left horizontal support rail The right hand V rail is approximately 158 mm 6 25 in away from the system center line Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the v rails from the wall as required 2 WALL MOUNT BRACKET 1342 85958 001 4 M6 12 mm SCREW 16...

Page 102: ...apping screws through each wall mount bracket Double check for plumb and level e Raise the right frame assembly and lean it against the wall Caution Wear safety glasses when installing the self tapping hex screws 158 mm 6 22 in WALL FLOOR CENTER LINE OF DUAL UNIT 4 WALL MOUNT BRACKET 1342 85958 001 8 12 24 1 25 mm SELF TAP HEX SCREW 1601 52879 001 ...

Page 103: ... assembly on the right horizontal support rail The distance between the frames is 315 mm 12 3 8 in Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the V rails from the wall as required Be sure to level between the two frame assemblies 2 WALL MOUNT BRACKET 1342 85958 ...

Page 104: ...r brackets using two M6 12 mm screws per joiner Locate the joiner with clips in the lower position Slide the right frame as required to align the screw holes 75 JOINER BRACKET 1342 85966 001 2 M5 x 10mm SCREW 1601 67756 001 2 CABLE CLIP 1661 12703 004 2 M6 x 12mm SCREW 1601 68586 001 CENTER LINE OF DUAL UNIT 2 75 DUAL JOINER BRACKET 1342 85966 001 4 M6 x 12mm SCREW 1601 68586 001 ...

Page 105: ...ystem Poly Inc 105 j With the joiners attached secure the right frame assembly to the horizontal support rail by driving two self tapping screws through each wall mount bracket Double check for level and plumb 8 SELF TAPPING SCREW 1601 52879 001 ...

Page 106: ...ses when installing the self tapping hex screws WALL FLOOR CENTER LINE OF DUAL UNIT 2 75 DUAL JOINER BRACKET 1342 85966 001 4 M6 x 12mm SCREW 1601 68586 001 4 WALL MOUNT BRACKET 1342 85958 001 158 mm 6 22 in 158 mm 6 22 in 316 mm 12 44 in 8 12 24 1 25 mm SELF TAP HEX SCREW 1601 52879 001 ...

Page 107: ...ps head screws supplied with the speakers Orient the speakers so that the tweeters are toward the outside l Partially thread in four M6 12 mm flanged button screws in the lower locations on the insides of the V rails Leave about half of the thread exposed 2 SPEAKER 2565 84879 001 4 M6 12 mm SCREW 1601 68586 001 BACK 4 M6 12 mm SCREW 1601 68586 001 ...

Page 108: ...mblies in place The speakers should be toward the outsides of the frames n Attach the RCA cables to the speakers Route the connectors behind the speaker brackets and through the openings in the brackets Connect the 3 cable to the left speaker and the 10 cable to the right Route the 10 cable across the right frame through the cable clips to the left frame ...

Page 109: ...V rails by installing four more M6 12 mm screws in the top slots of the brackets Tighten all eight screws p Partially install two M6 12mm screws into the outside top of each V rail of the left frame assembly Leave about half of the threads exposed 4 M6 12 mm SCREW 1601 68586 001 4 M6 12 mm SCREW 1601 68586 001 ...

Page 110: ...e version of the Medialign system being installed s Apply the regulatory label to the codec mounting bracket as indicated in the below image PDU 1583 52876 008 2 M4 x 8 mm SCREW 1601 42846 001 Poly Medialign Model P019 100 240V AC 6A 50 60 Hz Polycom Netherlands BV Skorpius 171 2132 LR Hoofddorp The Netherlands Medialign 65 Medialign 65D Installed Product Model Number Medialign 75 Medialign 75D Me...

Page 111: ... Medialign Dual Display System Poly Inc 111 t Attach the codec to the codec mounting bracket using two M3 8 mm thumb screws CODEC MOUNT BRACKET 1342 85957 001 2 M3 8 mm KNURLED THUMB SCREW 1601 85974 001 REGULATORY LABEL ...

Page 112: ...he codec mounting bracket assembly on the upper rail of the lower horizontal frame of the left assembly Slide the upper portion of the bracket behind the upper rail and then rotate it into place 2 M3 x 8mm KNURLED THUMB SCREW 1601 85974 001 CODEC MOUNT BRACKET 1342 85957 001 ...

Page 113: ... Run the coaxial cable along the horizontal support rail over to the left V rail x Connect a 1M C13 C14 cable to the power adapter Route it down behind the speaker bracket and rails and connect it to the PDU y Route the mini HDCI end of the EagleEye Director II camera cable through the codec mounting bracket behind the speaker bracket and support frames up to the horizontal support rail Run it alo...

Page 114: ...n the display b Remove the lower handles from the displays Store them carefully for future use Caution Three people may be required to lift the display especially if using the 12 risers Note You may prefer to connect the C13 C14 power cables to the displays before mounting If so connect a 1M C13 C14 cable to the left display and a 3M C13 C14 cable to the right display 75 TOUCH DISPLAY DISPLAY BRAC...

Page 115: ...he displays on the upper rails of the horizontal frames Locate them so they are centered on the frames with the bezels touching at the center line and so that holes and threaded inserts align Secure them using two M8 20mm screws per display 4 M8 x 20mm SCREW 1601 52713 001 ...

Page 116: ...op frame support bracket on the left fame assembly sliding it over the four M6 12mm screws previously installed Secure it by tightening all screws e Following the supplied instructions assemble the microphone column to the EagleEye Director II base Do not install the cameras yet ...

Page 117: ...t using the four screws supplied in the EagleEye Director II accessory kit g Pull the HDCI camera audio and camera power cables up and behind the top frame support bracket Connect them to the EagleEye Director II base EAGLEEYE DIRECTOR II 7230 69420 001 CAMERA MOUNT BRACKET 1342 86062 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTOR II ...

Page 118: ... F Y adapter cable to the codec audio out c Connect the camera audio cable RCA M connectors to the Y adapter red to red and white to white d Connect the RCA cable for the left speaker to the camera audio cable white RCA F e Route the RCA cable for the right speaker across the frames and through the cable clips Connect it to the camera audio cable red RCA F f Apply a ferrite bead to one end of the ...

Page 119: ...er adapter in the lower rail of the lower horizontal frame below the codec Route the cable up to the codec and connect it n Connect a 1M C13 C14 cable to the codec power adapter Route it up behind the frame and connect it to the PDU o Connect a 1M C13 C14 cable to the left display Route it down and connect to the PDU p Connect the 3M C13 C14 cable to the right display Route it across the frames th...

Page 120: ...Setting Up the Poly Medialign Dual Display System Poly Inc 120 9 Attach the optional riser covers If you installed the 6 risers attach the two 6 riser covers with magnets 2 6 RISER COVER 2345 85968 001 ...

Page 121: ...Setting Up the Poly Medialign Dual Display System Poly Inc 121 If you installed the 12 risers attach the two 12 riser covers with magnets 2 12 RISER COVER 2345 85969 001 ...

Page 122: ...Setting Up the Poly Medialign Dual Display System Poly Inc 122 10 Attach the two cover panels by hooking them onto the support brackets 2 COVER PANEL 2352 48053 X00 ...

Page 123: ...23 11 Attach the two speaker covers with magnets 12 If not already removed remove the lower display handles on both sides of the displays and attach the two side covers with magnets 13 Attach the two short side covers with magnets 2 SPEAKER COVER 2345 85967 001 ...

Page 124: ...n the center of the left speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the left front cover panel 5 08 cm 2 in from the left and top edges 2 SIDE COVER 2352 85971 001 2 SHORT SIDE COVER 2352 85973 001 OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 125: ...5 mm Screw 1601 67617 002 16 Speaker Mount Bracket 1342 85952 001 2 6 Riser Optional 1342 85959 001 4 Speaker 2565 84879 001 2 86 Dual Joiner Bracket 1342 85964 001 2 Cable Clip 1661 12703 004 2 M5 10 mm Screw 1601 67756 001 2 Wall Mount Bracket 1342 85958 001 4 12 24 1 25 Self tapping Hex Screw 1601 52879 001 8 Power Distribution Unit PDU 1583 52876 008 1 M4 8 mm Screw 1601 42846 001 2 Codec Moun...

Page 126: ...agleEye Director II Display Mount Bracket 1342 86063 001 1 M5 10 mm Flange Head Screw 1601 12997 001 7 6 Riser Cover Optional 2345 85968 001 2 Cover Panel Support Bracket 1342 85984 001 4 Cover Panel 2352 48053 100 Apple 2352 48053 400 Black 2352 48053 500 White 2352 48053 600 Slate Gray 2 Speaker Cover 2345 85967 001 2 Side Cover 2352 85971 001 2 Side Cover Short 2352 85973 001 2 Logo 2668 86065 ...

Page 127: ... causing possible serious personal injury The installer is responsible for conforming to all applicable building codes and local requirements Also ensure that the wall does not have vibrations that could cause the mounted camera to shake more likely to be seen when the camera is zoomed in You can feel the vibration in a wall by lightly placing your hand on the wall 613 5 mm 24 1 8 347 2 mm 13 5 8 ...

Page 128: ... in from the floor using eight wall anchors per rail appropriate for your wall type not supplied Use the upper and lower holes in the rail You must anchor to a minimum of three studs per rail 1081 10mm 42 56in 536 00mm 21 10in 268 00mm 10 55in 1665 00mm 65 55in FLOOR WALL CENTER LINE OF DUAL UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 129: ...height you can add a 6 riser With a 6 riser attach the horizontal support rails 1219 48 mm 48 01 in from the floor using eight wall anchors appropriate for your wall type not supplied 1219 48 mm 48 01 in 536 00 mm 21 10 in 268 00 mm 10 55 in 1665 00 mm 65 55 in FLOOR WALL CENTER LINE OF DUAL UNIT HORIZONTAL SUPPORT RAIL 1354 84599 001 ...

Page 130: ...the floor with the feet toward the wall where you plan to anchor the frame Space them approximately 1350 mm 53 in apart Orient the rails face down open side up b Screw the leveling feet out until the lower edges of the feet extend 34 mm 1 5 16 beyond the end of the V rail 1350 mm 53 in Open Side Up Open Side Up 34 mm 1 5 16 in ...

Page 131: ...veling feet from the V rails and install them in the risers Screw them in to the risers until the lower edges of the feet extend 34 mm 1 5 16 beyond the end of the riser Slide the risers on the V rails and attach them using two M6 12mm screws per riser 2 M6 x 12mm SCREW 1601 68586 001 34 mm 1 5 16 in ...

Page 132: ...large screw holes up away from the wall Orient the lower frame with the large screw holes down toward the wall Attach the frames to the V rails using four M10 25mm screws per frame 4 Repeat step 3 for the right frame 5 Raise the frame assemblies and continue the installation a Raise the left frame assembly and lean it against the wall HORIZONTAL FRAME 2350 85976 001 FRAME V RAIL 2350 85975 001 FRA...

Page 133: ...embly on the left horizontal support rail The right V rail is approximately 256 mm 10 1 in away from the system center line Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the V rails from the wall as required 2 WALL MOUNT BRACKET 1342 85958 001 4 M6 12 mm SCREW 1601...

Page 134: ...iving two self tapping screws through each wall mount bracket Double check for plumb and level e Raise the right frame assembly and lean it against the wall Caution Wear safety glasses when installing the self tapping hex screws WALL FLOOR CENTER LINE OF DUAL UNIT 256 mm 10 1 in 8 12 24 1 25 mm SELF TAP HEX SCREW 1601 52879 001 ...

Page 135: ...t horizontal support rail The distance between the frames IS approximately 512 mm 20 1 8 in Move the frame close to the wall so that the vertical rails are approximately 5 cm 2 in away from the wall Check for plumb and level adjusting the leveling feet and the distance of the V rails from the wall as required Be sure to level between the two frame assemblies 2 WALL MOUNT BRACKET 1342 85958 001 4 M...

Page 136: ...lign Dual Display System Poly Inc 136 h Attach two cable clips to one of the 86 dual joiner brackets using one M5 10 mm screw per clip 86 JOINER BRACKET 1342 85964 001 2 M5 10 mm SCREW 1601 67756 001 2 CABLE CLIP 1661 12703 004 ...

Page 137: ...ate the joiner with clips in the lower position Slide the right frame as required to align the screw holes 256 mm 10 1 in WALL FLOOR CENTER LINE OF DUAL UNIT 2 86 DUAL JOINER BRACKET 1342 85966 001 4 M6 x 12mm SCREW 1601 68586 001 4 WALL MOUNT BRACKET 1342 85958 001 256 mm 10 1 in 496 60 mm 19 55 in 8 12 24 1 25 mm SELF TAP HEX SCREW 1601 52879 001 ...

Page 138: ...all mount bracket Double check for level and plumb k Attach one speaker to each of the speaker mount brackets using the M6 12 mm Phillips head screws supplied with the speakers Orient the speakers so the tweeters are toward the outside Caution Wear safety glasses when installing the self tapping hex screws 8 SELF TAPPING SCREW 1601 52879 001 2 SPEAKER 2565 84879 001 4 M6 12 mm SCREW 1601 68586 001...

Page 139: ...dialign Dual Display System Poly Inc 139 l Partially thread in four M6 12 mm flanged button screws in the lower locations on the insides of the V rails Leave about half of the thread exposed 4 M6 X 12 mm SCREW 1601 68586 001 ...

Page 140: ...emblies over the screws and swing the assemblies in place The speakers should be toward the outsides of the frames n Attach the RCA cables to the speakers Route the connectors behind the speaker brackets and through the openings in the brackets Connect the 3 cable to the left speaker and the 10 cable to the right ...

Page 141: ...ialign Dual Display System Poly Inc 141 o Secure the speaker bracket assemblies to the V rails by installing four more M6 12 mm screws in the top slots of the brackets Tighten all eight screws 4 M6 12 mm SCREW 1601 68586 001 ...

Page 142: ... Medialign Dual Display System Poly Inc 142 p Install the PDU on the top rail of the lower horizontal frame of the left frame assembly using two M4 8 mm Phillips screws PDU 1583 52876 008 2 M4 x 8 mm SCREW 1601 42846 001 ...

Page 143: ...the below image s Attach the codec to the codec mounting bracket using two M3 8 mm thumb screws Poly Medialign Model P019 100 240V AC 6A 50 60 Hz Polycom Netherlands BV Skorpius 171 2132 LR Hoofddorp The Netherlands Medialign 65 Medialign 65D Installed Product Model Number Medialign 75 Medialign 75D Medialign 86 Medialign 86D CODEC MOUNT BRACKET 1342 85957 001 2 M3 8 mm KNURLED THUMB SCREW 1601 85...

Page 144: ...the codec mounting bracket assembly on the upper rail of the lower horizontal frame of the left assembly Slide the upper portion of the bracket behind the upper rail and then rotate it into place 2 M3 8 mm KNURLED THUMB SCREW 1601 85974 001 CODEC MOUNT BRACKET 1342 85957 001 ...

Page 145: ...un the coaxial cable along the horizontal support rail over to the left V rail w Connect a 1M C13 C14 cable to the power adapter Route it down behind the speaker bracket and rails and connect it to the PDU x Route the mini HDCI end of the EagleEye Director II camera cable through the codec mounting bracket behind the speaker bracket and support frames up to the horizontal support rail Run it along...

Page 146: ...n the display b Remove the lower handles from the displays Store them carefully for future use c Hang displays on the upper rails of the horizontal frames Locate them so they are centered on the frames the bezels touching at the center line and so that holes and threaded inserts align Double check plumb and level Caution Three people are required to lift the display 86 DISPLAY 6 M8 20 mm SCREW 160...

Page 147: ...Setting Up the Poly Medialign Dual Display System Poly Inc 147 d Secure the displays to the frame assemblies using two M8 20 mm screws per display 2 M8 20 mm SCREW 1601 52713 001 ...

Page 148: ...the back of the displays Secure the clip using two M5 10 mm flange head screws Slide a clip over the lower pair of shoulder screws securing the clip with two M5 10 mm flange head screws f Following the supplied instructions assemble the microphone column to the EagleEye Director II base Do not install the cameras yet 4 M5 10 mm SCREW 1601 12997 001 2 86 DISPLAY JOINER CLIP 1342 85965 001 ...

Page 149: ...a mount using the four screws supplied in the EagleEye Director II accessory kit h Pull the HDCI camera audio and camera power cables up and behind the top frame support bracket Connect them to the EagleEye Director II base EAGLEEYE DIRECTOR II DISPLAY MOUNT BRACKET 1342 86063 001 4 HARDWARE SUPPLIED WITH EAGLEEYE DIRECTOR II ...

Page 150: ...o white d Connect the RCA cable for the left speaker to the camera audio cable white RCA F e Route the RCA cable for the right speaker across the frames and through the cable clips Connect it to the camera audio cable red RCA F f Apply a ferrite bead to one end of the 2M HDMI cable Connect that end of the cable to the left display HDMI 1 input and the codec primary HDMI output g Apply a ferrite be...

Page 151: ...ble to the left display Route it down and connect to the PDU n Connect the 3M C13 C14 cable to the right display Route it across the frames through the cable clips and connect to the PDU o Connect the mains cable to the wall outlet Route it behind the frame and connect it to the PDU p Connect the network cable to the network port Route it behind the frame and connect it to the codec network port q...

Page 152: ...Setting Up the Poly Medialign Dual Display System Poly Inc 152 9 If you installed the 6 risers attach the two 6 riser covers with magnets 2 6 RISER COVER 2345 85968 001 ...

Page 153: ...Setting Up the Poly Medialign Dual Display System Poly Inc 153 10 Attach the two cover panels by hooking them onto the support brackets 2 COVER PANEL 2352 48053 X00 ...

Page 154: ...54 11 Attach the two speaker covers with magnets 12 If not already removed remove the lower display handles on both sides of the displays and attach the two side covers with magnets 13 Attach the two short side covers with magnets 2 SPEAKER COVER 2345 85967 001 ...

Page 155: ...n the center of the left speaker cover Optionally you can peel the liner from the logo and attach it in the top left corner of the left front cover panel 5 08 cm 2 in from the left and top edges 2 SIDE COVER 2352 85971 001 2 SHORT SIDE COVER 2352 85973 001 OPTIONAL LOGO LOCATION LOGO 2668 86065 001 ...

Page 156: ...echnician must perform service or repair work Avoid using this system during an electrical storm There may be a remote risk of electric shock from lightning SAVE THESE INSTRUCTIONS Ambient Temperature Guidelines Operating temperature 32 to 104ºF 0 to 40ºC System Rating Note the location of the rating label on the codec bracket Identify the installed version on the rating label 100 240V AC 6A 50 60...

Page 157: ...y that all socket outlets from which the equipment is to be powered provides a connection to the building protective earth To verify use a suitable long test wander lead with an ohm meter multimeter Connect one end to a known protective earthing point of the building electrical installation and ensure that there is a reading of less than one ohm to each earthing contact of all socket outlets to be...