background image

4

Enclosed Waterfall

CAUTION: WHEN SERVICING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING. 

Midwest Tropical Inc • 3420 West Touhy Ave • Skokie, IL 60076 USA • Phone: (847)679-6666 • Fax: (847)679-6669 

Your waterfall ships inside of a wooden crate to protect the waterfall 
from damage.  

Your container indicates which side is the front of the waterfall.

1.  Position the package so that the front is facing towards the ceiling.

2.  Starting with the front panel of the shipping container, use the 

drill with the No. 2 Phillips bit to remove all of the screws. 

3.  Remove the cardboard. The waterfall is wrapped in plastic and 

surrounded by protective insulation foam. Remove the top layer 
of insulation foam, but do not throw it away. You can reuse the 
foam to protect the stainless steel while you move it into its final 
position. 

4.  Remove the remaining wooden panel pieces and cardboard from 

the shipping container. 

5.  Once all of the wood is removed, lift the waterfall to a standing 

position. Leave the metal header off until the waterfall is in its 
final position.  
CAUTION Because the waterfall is very heavy, it is best to use 
four people to move and position it.  

6.  Use the platform dollies to move the waterfall near its final 

location, if necessary. 

•  To position the dollies under the base, tip the base on one 

of the short edges.  Roll one of the platform dollies under the 
lifted base edge. Lower the base onto the platform dolly and 
carefully tilt the waterfall so that the other dolly can be rolled 
underneath the opposite side. Move the waterfall nearest to the 
final location as possible. 

•  To remove from dollies, lift one side of the waterfall, remove 

a dolly then rest the base onto the floor. Do the same for the 
other side. 

Uncrate the 

shipping 

container

Uncrate the waterfall

Summary of Contents for Habitat Soundscaping

Page 1: ...INSTALLATION MAINTENANCE Enclosed Waterfall Installation Guide...

Page 2: ...3 What s in the box 3 Uncrate the waterfall 4 Waterfall overview 5 Installation 6 First time operation 9 Lighting operation optional 11 General operation Valve overview 12 Troubleshooting 13 Surface c...

Page 3: ...Liquid level Ladder or scissor lift Phillips screw driver Tablespoon measuring spoon Access to 120VAC 20 AMP Duplex outlet US Standard outlet Extension cord optional Rubber mallet What you need for i...

Page 4: ...l while you move it into its final position 4 Remove the remaining wooden panel pieces and cardboard from the shipping container 5 Once all of the wood is removed lift the waterfall to a standing posi...

Page 5: ...ical Inc 3420 West Touhy Ave Skokie IL 60076 USA Phone 847 679 6666 Fax 847 679 6669 Waterfall overview VIEW FROM TOP UV sterilizer lamp housing Drain valve Fill valve Water pump Quick disconnects LED...

Page 6: ...t the thinnest end of a shim between the floor and the bottom of the waterfall unit Check the level again Use a mallet to tap the shim further into the underside of the base if necessary Repeat the pr...

Page 7: ...lamp housing Screw the ballast back into the lamp housing until it is hand tight Do not overtighten 6 Screw the lamp housing back into the base plumbing 7 Do a quick check to make sure the UV light p...

Page 8: ...ich will dissolve as you add the distilled water We recommend Robelle Oxidizing Shock Swim Monopersulfate NOTE Treat water with 1 tablespoon monopersulfate every 6 months See maintenance instructions...

Page 9: ...icular to pipe UV inlet valve Open parallel to pipe UV outlet valve Open parallel to pipe Connect all cables to standard US outlet or supplied power strip There are 3 cables with the optional lighting...

Page 10: ...y control valve to control the water flow through the spray bar to create the waterfall effect Adjust to ensure that there are no dry spots on the panel Adjust the UV inlet valve flow until the founta...

Page 11: ...uilt in programs 8 static colors 8 color dreaming modes and 8 color changing modes Presets Press button 0 9 to choose a static color and the two built in programs 0 black 5 yellow 1 red 6 purple 2 gre...

Page 12: ...low through the UV sterilizer and to the fountain feature at the base of the enclosed panel UV outlet valve Keep open parallel to pipe unless you are servicing the UV sterilizer Water pump valve Keep...

Page 13: ...nect fittings above the spray bar Check seal at top of enclosed panel and ensure screws are fully tightened Symptom Problem Solution Uneven water flow Pump is loud has sucking sound Leaking water Ligh...

Page 14: ...ber cloth to remove blemishes such as fingerprints and dust For tougher stains use Novus acrylic cleaner or Dish detergent and water mixture and clean microfiber cloth We recommend Novus acrylic clean...

Page 15: ...all from power 2 Ensure the drain valve is closed perpendicular to pipe VIEW FROM REAR Drain valve Fill valve 3 Connect the fill insert spout and funnel supplied into the fill valve 4 Open the fill va...

Page 16: ...fall Add water treatment and distilled water 1 Disconnect power to the waterfall 2 Prepare buckets for waste water 3 Remove front base lid 4 Connect the drain fitting to the drain insert and tubing su...

Page 17: ...oducing UV wavelength The bulb will produce visible light long after it has stopped producing UV The valves on the UV sterilizer should remain in the on parallel to plumbing position until you are rea...

Page 18: ...water pump valves to the OFF position perpendicular to pipe This will prevent water from draining from the waterfall while servicing However water will be inside the pump so have towels on hand 4 Remo...

Page 19: ...lids conceal the base To prevent damage to stainless steel remove and replace the lids using suction cup glass holders Header The stainless steel cover for the acrylic panel top spray bar and plumbing...

Page 20: ...nt pump operation No plumbing required Power requirements 120 V 60 Hz Power consumption 720 W Power requirements 120 V 60 Hz Power consumption 220 W 40 watt output Max flow rate to kill bacteria 2000...

Page 21: ...ubmersible or non submersible Fountain Pump grounded cord connected All pumps are rated 120 V 60 Hz Certified in accordance with UL 778 fourth ed Motor Operated Water Pumps and power and types as indi...

Page 22: ...17 2008 Revised Jan 11 2010 james highendled com mark wdmlighting com No 70 Yuangang Road Tianhe District Guangzhou 510650 China 972 650 1855 86 020 37089936 4016 Harry Hines Blvd Dallas TX 75219 Chi...

Page 23: ...ING YOUR WATER FEATURE MAKE SURE THAT YOU DISCONNECT ALL ELECTRICAL AND LIGHTING Midwest Tropical Inc 3420 West Touhy Ave Skokie IL 60076 USA Phone 847 679 6666 Fax 847 679 6669 Safety Certifications...