After closing down the fuel filler flap the LED lights on 

PrimeFire

 will indicate: 

 

 

PrimeFire

 is ready to use, 

or 

 

 

Too little fuel was pumped, repeat refueling. 

 

3.

 

Starting the device. The green indicator 

 flashes on the control panel  .  

3.1. Press the 

START/STOP

 button on the control panel and hold it until you hear the sound signal. 

3.2 The green led READY will start blinking to indicate starting the device and the filament will start to glow. Wait until 
the fire appears. 

3.3. While the appliance is in work mode, the green indicator goes off and the flame starts to appear. The device works 
automatically until they run out of fuel or disable the device by the user. 

Depending on the temperature and amount of fuel, the startup sequence may take up to 10 minutes. When the LEDs are off, they 
will go out.

 

C.

 

Flame size regulation 

The 

PrimeFire

 can operate in two modes: Normal and ECO. The device always starts with a standard flame size. The device has the 

adjustable flame size during operation.  

In order to reduce the height of the flame, press the ECO button. You will hear two beeps and the ECO button will be highlighted. 

The unit is now operating in ECO mode. 

To return to the normal height of the flame, press the ECO button, you will hear one beep and the ECO button backlight turns off. 

The device is now in normal mode. 

ATTENTION!

 It might take a few moments for the flame to adjust. 

ATTENTION!

 The device switches to ECO mode by itself when there is a danger of over-temperature of the device. 

D.

 

Device extinguishing 

Press the 

START/STOP

 button on the control panel. You will hear two beeps and the red indicator 

 will start to blink. 

The blinking red indicator means that the device is too hot to be restarted. When the device cools the message will disappear, and 
depending on the amount of the fuel in the tank, either the green indicator will flash and indicate the readiness for operation or 
the blue indicator will indicate the lack of the fuel. 

E.

 

Subsequent start up 

If on the control panel flashes the blue FUEL 

 indicator, start to run the product from the point B.2. 

If on the control panel flashes the green READY 

 indicator, you can: 

 

start to run the product from the point B.3. 

 

fill the fuel in accordance with B.2 paragraph. 

 

READY

F U E L

READY

HOT

F U E L

READY

 

During pouring be careful not to spill out the fuel. If the fuel is spilled error message 

 

may be displayed. 

Go to step F, and follow the guidance provided in the  table. 

If the spillage is excessive  the source of 

power needs to be disconnected. 

READY

FUEL

HOT

Summary of Contents for PrimeFire#4 Logs

Page 1: ...USER S MANUAL PrimeFire 4 Logs Manufactured by Planika Sp z o o ul Bydgoska 38 86 061 Brzoza Poland Edition i1286 01 as of 30 10 2017 Serial number greater than P6210 17 ...

Page 2: ... I General information 3 II Fuel 3 III Safety 4 IV Operation 5 A Operating elements 5 B Initial start up of the device 6 C Flame size regulation 7 D Device extinguishing 7 E Subsequent start up 7 F FAST START function 8 G Information and warning alert 8 V Cleaning and maintenance 10 VI Disposal and recycling 10 VII Service 10 ...

Page 3: ...ts operators Manufacturer will not accept any responsibility in case of using any other fuel than recommended i e dehydrator and or super purified ethanol with more than 96 6 ethanol volume or any other which doesn t meet above mentioned properties Explanation of symbols is placed on the placed on the flap of the device It is forbidden to pour fuel into a burning device It is forbidden to pour fue...

Page 4: ...uel FANOLA or the fuel recommended in section II Supplies and consumables Do not heat the fuel before the heating process of the device is started Do not start the device in case of spillage of fuel out of the tank Never pour fuel directly into the flame tray as this may cause damage to the device and result in fire Such an attempt may cause violent ignition result in fire burns and can even be li...

Page 5: ...he device is properly installed according to the instructions and the manual A Operating elements Control Panel START STOP READY FUEL HOT ERROR PAT PEND ECO START STOP READY FUEL HOT ERROR PAT PEND ECO Fire grate Glowing coil Fanola filler bolt Furnace Logs Service USB input hidden under a cap Starts the device from standby mode or switches to the standby Switches to ECO mode The red indicator The...

Page 6: ...e placed firmly in their place Place the stiff tube in the external fuel container from which the fuel will be pumped out into the PrimeFire s fuel tank To start the automatic pump squeeze the rubber manual pump several times until you will hear the buzzing noise Automatic fuel pump will start working once the fuel reaches the sensor inside the black box Pump will cease the refuelling process once...

Page 7: ...w operating in ECO mode To return to the normal height of the flame press the ECO button you will hear one beep and the ECO button backlight turns off The device is now in normal mode ATTENTION It might take a few moments for the flame to adjust ATTENTION The device switches to ECO mode by itself when there is a danger of over temperature of the device D Device extinguishing Press the START STOP b...

Page 8: ...hold down ECO button for about 10 s until you hear 4 beeps To re enable the FAST START function hold down ECO button for about 10s until you hear 2 beeps WARNING With FAST START function enabled the device consumes 60 W of energy G Information and warning alert In order to increase safety the PrimeFire is equipped with an electronic system to keep the operation safe In the case of a dangerous situ...

Page 9: ...source of power needs to be disconnected Wait at least 1 hour to evaporate the remaining moisture and then close the fuel filler bolt If the alarm message reappears wait a little bit longer until the rest of the moisture evaporates If the message reappears contact your service provider The time given for the flame to appear has been exceeded If the alarm message appears during the start of the dev...

Page 10: ...uation where it will be necessary to clean elements not normally available The manufacturer is not liable for damage resulting from improper operation non manual self dismantling attempts to modify using other liquids than those recommended in point II Fuel VI Disposal and recycling The product is equipped with parts made of aluminium steel plastics and electronics If you need to dispose of the de...

Reviews: