3.
OPERATING INSTRUCTIONS
3.1.
General Notes
The GaLiO Insert fireplace is equipped with GV60 gas valve with a built-in ignition for the pilot flame. The flame height
of the main burner, as well as Start and Stop of the appliance, is controlled by Wall Switch.
Figure 1: Wall Switch
3.2.
Installing the control unit (Wall Switch)
The control unit has standard a cable with a length of 8 meters (connection for battery supply and for the controlling).
NOTE:
The cables
may not
be extended. Longer cables can pick up environmental signals that can switch the appliance
uncontrolled On or Off.
•
Determine the location for the control unit (Wall Switch).
•
Pull the cables through the opening
of
50 x 80 mm
on the surface on which Wall Switch will be mounted.
•
Make sure you have ca
12 cm
cable length outside of the opening for replacing the batteries.
•
Connect the switch with the cable and insert the plug into the terminal.