background image

Copyright Planika Sp. z o.o.  

www.planikafires.com 

 

IG0097#02 

20.02.2018 

 

11 

5.2.

 

Glass cleaning  (if optionally installed) 

Most of the existing types of smudges may be wiped with a dry cloth. In case of more substantial smudge you may use 

liquids normally applied to ceramic tiles or windows. Always dry the glass screen to avoid damp patches which could 

irreversibly embed into the glass. 

Warning!!!

 

Avoid leaving fingerprints on the glass. They will be embedded into the glass and you will not be able to 

clean them. 

 

 

6.

 

TROUBLESHOOTING 

Warning! Montage, upkeep and service need to be conducted by a qualified professional with appropriate 

qualification, an appropriate company or the gas supplier. 

 

PROBLEM

 

POSSIBLE CAUSE

 

CORRECTIVE ACTION

 

SMELL OF GAS

 

CLOSE THE VALVE ON THE GAS CYLINDER IMMEDIATELY. DO NOT USE 
THE DEVICE UNTIL LEAKS HAVE BEEN REMOVED.

 

Leak detected at cylinder, 
regulator or other 
connection.

 

1. A loose regulator linkage. 
2. Leak in the gas linkage, in the 
regulator or on the gas knobs.

 

1. Tighten and test it. 
2. Report this issue to service.

 

Burner does not ignite

 

1. The bottle is empty. 
2. Igniter linkage is not connected. 
3. No ignition spark. 
4. The igniter electrode is placed 
incorrectly opposite the igniter. 
5. Gas nozzles are blocked. 
6. Gas linkage is twisted. 
 
7. Pressure regulator link is loose.

 

1. Replace Gas Cylinder. 
2. Connect the igniter linkage. 
3. Replace igniter. 
4. Realign electrode and clear any 
surrounding debris from area. 
5. Unmount burner, clean the nozzle. 
6. Straighten the linkage. Keep the 
linkage away from the housing. 
7. Tighten the link. Check for leaks.

 

Igniter Not Working 

1. Ignitor wire not connected. 
 
2. Electrode misaligned on pilot 
burner 
3. Igniter malfunction 

1. Ensure pilot electrode wire is 
connected. 
2. Realign electrode and clear any 
surrounding debris from area. 
3. Replace Igniter 

Low efficiency, „cracking” 
sounds

 

1. The bottle is empty. 
2. The nozzles of the burner are 
blocked.

 

1. Replace Gas Cylinder. 
2. Unmount the burner, clean the 
nozzle.

 

Thumping sounds made 
by the regulator. 

The cylinder valve has opened 
rapidly. 

Unfasten the bottle valve slowly. 

A vivid/ bright orange and 
smoky flame of the 
burner. 

Holes blocked in the apparatus 
producing the gas and air mixture. 

Unmount the burner and clean/ 
unblock the apparatus’ holes. 

 

 

 

 

 

 

 

Summary of Contents for GaLiO Insert #2

Page 1: ...ht Planika Sp z o o www planikafires com IG0097 02 20 02 2018 1 USER S MANUAL GaLiO Insert 2 G20 G25 Natural Gas G30 G31 Propane Butane Propane Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland ...

Page 2: ...NG INSTRUCTIONS 5 3 1 General Notes 5 3 2 Installing the control unit Wall Switch 5 3 3 Replacing the batteries 6 3 4 Operating 8 3 4 1 Automatic Turn Down To Pilot 9 3 4 2 Automatic Shut Off 9 4 TESTING 10 4 1 Checking for gas leaks 10 4 2 Checking the flame appearance 10 5 MAINTENANCE AND UPKEEP 10 5 1 Testing and cleaning 10 5 2 Glass cleaning if optionally installed 11 6 TROUBLESHOOTING 11 7 T...

Page 3: ...threat of damaging the unit or causing a fire A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition the GaLiO Insert fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working The GaLiO Insert...

Page 4: ...r recommended 50 mbar Use only regulators complying with the European EN16129 Norm Use only approved and certified gas connection linkage Replace the linkage every 2 years The elastic linkage connecting gas to the fireplace is to be led away from sharp edges and hot surfaces Refrain from bends and twists of the elastic connection on its full length Remember that the LPG bottle should be stored in ...

Page 5: ... Switch The control unit has standard a cable with a length of 8 meters connection for battery supply and for the controlling NOTE The cables may not be extended Longer cables can pick up environmental signals that can switch the appliance uncontrolled On or Off Determine the location for the control unit Wall Switch Pull the cables through the opening of 50 x 80 mm on the surface on which Wall Sw...

Page 6: ...ommend to place the battery holder in the same casing located on the Wall Switch rear wall bracket or in a separate casing of the same waterproof class not less than IP64 3 3 Replacing the batteries If the batteries are inserted incorrectly the electronics or drive may be irreparably damaged Only replace the batteries when the appliance has been completely switched off NOTE If the appliance is equ...

Page 7: ...nikafires com IG0097 02 20 02 2018 7 Unscrew the Wall Switch plate Remove the battery holder Replace 4 pieces of AA LR6 Alkaline long live batteries Replace the battery holder and mount the Wall Switch plate Screw the Wall Switch plate ...

Page 8: ...ON Appliance Press ON OFF button see Figure 3 until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed there is main gas flow Standby Mode Pilot Flame Press and hold small flame button to set appliance at pilot flame To Turn OFF Appliance Press ON OFF button Flame Height Adjustment Press and hold large flame button to increase flame height Press an...

Page 9: ...figuration the temperature must not exceed 60 C Powered by batteries and or connected to the V module The valve turns to pilot position if the temperature in the receiver is higher than 140 F 60 C NOTE When the receiver temperature is below 140 F 60 C the main burner can be turned ON manually 3 4 2 Automatic Shut Off Low Battery Receiver With low battery power in the receiver the system shuts off ...

Page 10: ...e placement of decorative stones in such a way for them to be evenly placed on the whole surface of the main burner WARNING Remember not to cover the cover which houses the ignition and the pilot flame with stones Turn on the fireplace and check the appearance of the flame once again 5 MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is starte...

Page 11: ...this issue to service Burner does not ignite 1 The bottle is empty 2 Igniter linkage is not connected 3 No ignition spark 4 The igniter electrode is placed incorrectly opposite the igniter 5 Gas nozzles are blocked 6 Gas linkage is twisted 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris f...

Page 12: ...sure mbar 30 37 50 20 Gas flow at 15 C and 1013 mbar m3 h 1 0 Gas flow at 15 C and 1013 mbar kg h 0 81 0 93 1 02 Burner pressure at max flame height mbar 22 2 27 3 35 4 11 0 Nozzle of the main burner mm 2 2 2 2 2 2 2 7 Pilot unit G30 ZP2M L G30 ZP2M L G30 ZP2M L G30 ZP2M L Gas control valve Mertik GV 60 Mertik GV 60 Mertik GV 60 Mertik GV 60 Gas linkage Ø9mm Ø9mm Ø9mm External 8 MANUFACTURER S CON...

Reviews: