4.

 

TESTING 

WARNING!!! 

NEVER TURN ON THE DEVICE IF THE CHARACTERISTIC SMELL OF GAS IS PERCEPTIBLE.

 

If you smell gas during the operation of the fireplace turn off the device immediately and cut off the gas supply from 

the gas cylinder by shutting its valve. 

4.1.

 

Checking for gas leaks 

 

Check if all connections are airtight. 

 

To  do  that  apply  all  connections  with  soapy  water  (or  water  with  another  foamy  substance)  or  with  a 

professional spray for leak detection. 

 

If air-bubbles are present that means the connection has a leak.  

 

Remove the leaks in the identified spaces. 

 

Check for leaks once again. 

 

After the inspection dry the inspected connections. 

 

The device may only be used again after all leaks are removed. 

 

If the problem happens again please contact the dealer. 

4.2.

 

Checking the flame appearance 

 

Burn the GaLiO Insert on max flame height and check the appearance of the flame. 

 

The flame should be linear and evenly placed on the whole length of the main burner. 

 

If visible gaps are present or there are substantial differences in flame height turn off the fireplace and after 

the device is cooled adjust the placement of decorative stones in such a way for them to be evenly placed on 

the whole surface of the main burner. 

 

WARNING!!!

 

Remember not to cover the cover, which houses the ignition and the pilot flame, with stones!  

 

Turn on the fireplace and check the appearance of the flame once again. 

5.

 

MAINTENANCE AND UPKEEP 

We recommend cleaning the pilot flame and the main burner unit before the device is started again after its 

been removed from storage during the winter period. 

5.1.

 

Testing and cleaning 

Please check and clean if necessary: 

 

The main burner - if necessary, remove broken parts of stones and the existing dust. 

 

Pilot burner and thermo-couple (if necessary, remove the existing sediment). In the event of visible damage 

contact your dealer. 

 

Igniter - gap between igniter and pilot flame should not be bigger than 5 mm. 

 

Glass screens – check for dirt smudges or possible scratches or cracks. If cracks are present replace the glass 

screen for a new one. To conduct this contact your dealer. 

 

Gas linkage and pressure regulator (in case their expiry date is invalid replace these ancillaries for new ones).  

 

If you encountered problems with the regulator, gas linkage, burner or regulation valves do not try to fix these 

parts. Contact a sales person, an authorised service or an importer in order to acquire spare parts. To ensure 

the device is working efficiently use only original spare parts. 

 

Summary of Contents for GaLiO Insert #2

Page 1: ...ht Planika Sp z o o www planikafires com IG0097 02 20 02 2018 1 USER S MANUAL GaLiO Insert 2 G20 G25 Natural Gas G30 G31 Propane Butane Propane Manufactured by Planika Sp z o o Bydgoska 38 86 061 Brzoza Poland ...

Page 2: ...NG INSTRUCTIONS 5 3 1 General Notes 5 3 2 Installing the control unit Wall Switch 5 3 3 Replacing the batteries 6 3 4 Operating 8 3 4 1 Automatic Turn Down To Pilot 9 3 4 2 Automatic Shut Off 9 4 TESTING 10 4 1 Checking for gas leaks 10 4 2 Checking the flame appearance 10 5 MAINTENANCE AND UPKEEP 10 5 1 Testing and cleaning 10 5 2 Glass cleaning if optionally installed 11 6 TROUBLESHOOTING 11 7 T...

Page 3: ...threat of damaging the unit or causing a fire A CO2 or a powder fire extinguisher needs to be placed near the device During the first ignition the GaLiO Insert fireplace needs to be burnt on maximum level for a few hours in order for the elements to acquire correct temperature and for the remains of paint lacquer and lubricant to evaporate Do not move the device while it s working The GaLiO Insert...

Page 4: ...r recommended 50 mbar Use only regulators complying with the European EN16129 Norm Use only approved and certified gas connection linkage Replace the linkage every 2 years The elastic linkage connecting gas to the fireplace is to be led away from sharp edges and hot surfaces Refrain from bends and twists of the elastic connection on its full length Remember that the LPG bottle should be stored in ...

Page 5: ... Switch The control unit has standard a cable with a length of 8 meters connection for battery supply and for the controlling NOTE The cables may not be extended Longer cables can pick up environmental signals that can switch the appliance uncontrolled On or Off Determine the location for the control unit Wall Switch Pull the cables through the opening of 50 x 80 mm on the surface on which Wall Sw...

Page 6: ...ommend to place the battery holder in the same casing located on the Wall Switch rear wall bracket or in a separate casing of the same waterproof class not less than IP64 3 3 Replacing the batteries If the batteries are inserted incorrectly the electronics or drive may be irreparably damaged Only replace the batteries when the appliance has been completely switched off NOTE If the appliance is equ...

Page 7: ...nikafires com IG0097 02 20 02 2018 7 Unscrew the Wall Switch plate Remove the battery holder Replace 4 pieces of AA LR6 Alkaline long live batteries Replace the battery holder and mount the Wall Switch plate Screw the Wall Switch plate ...

Page 8: ...ON Appliance Press ON OFF button see Figure 3 until two short beeps confirm the start sequence has begun release button Once pilot ignition is confirmed there is main gas flow Standby Mode Pilot Flame Press and hold small flame button to set appliance at pilot flame To Turn OFF Appliance Press ON OFF button Flame Height Adjustment Press and hold large flame button to increase flame height Press an...

Page 9: ...figuration the temperature must not exceed 60 C Powered by batteries and or connected to the V module The valve turns to pilot position if the temperature in the receiver is higher than 140 F 60 C NOTE When the receiver temperature is below 140 F 60 C the main burner can be turned ON manually 3 4 2 Automatic Shut Off Low Battery Receiver With low battery power in the receiver the system shuts off ...

Page 10: ...e placement of decorative stones in such a way for them to be evenly placed on the whole surface of the main burner WARNING Remember not to cover the cover which houses the ignition and the pilot flame with stones Turn on the fireplace and check the appearance of the flame once again 5 MAINTENANCE AND UPKEEP We recommend cleaning the pilot flame and the main burner unit before the device is starte...

Page 11: ...this issue to service Burner does not ignite 1 The bottle is empty 2 Igniter linkage is not connected 3 No ignition spark 4 The igniter electrode is placed incorrectly opposite the igniter 5 Gas nozzles are blocked 6 Gas linkage is twisted 7 Pressure regulator link is loose 1 Replace Gas Cylinder 2 Connect the igniter linkage 3 Replace igniter 4 Realign electrode and clear any surrounding debris f...

Page 12: ...sure mbar 30 37 50 20 Gas flow at 15 C and 1013 mbar m3 h 1 0 Gas flow at 15 C and 1013 mbar kg h 0 81 0 93 1 02 Burner pressure at max flame height mbar 22 2 27 3 35 4 11 0 Nozzle of the main burner mm 2 2 2 2 2 2 2 7 Pilot unit G30 ZP2M L G30 ZP2M L G30 ZP2M L G30 ZP2M L Gas control valve Mertik GV 60 Mertik GV 60 Mertik GV 60 Mertik GV 60 Gas linkage Ø9mm Ø9mm Ø9mm External 8 MANUFACTURER S CON...

Reviews: