Chapter 1 Introduction 

The PLNET UPS-400 protects critical data by supplying reliable, network-grade 

power in rack-optimized form the network. Working as an UPS, the UPS-400 takes 

over the power provision to the WGSW-2620PV when the AC power is shut off. It 

also support power to the PoE powered devices with its 400 watts power supply. As 

the WGSW-2620PV takes both 100~240V AC and 48VDC power input, the UPS-400 

acts also the redundant power supply for the network system. 

1.1 Product Description 

The UPS-400 is an UPS and the redundant power for WGSW-2620PV. There are 

two ways to supply power to the WGSW-2620PV. One is the 100~240V AC universal 

power supply, the other is the 48V DC by the UPS-400 Uninterruptible Power Supply. 

Once both the AC and the DC are used, the UPS-400 take the UPS-400 as the 

redundant power supply for power backup to prevent the power interrupt. This 

protects the critical data from the PoE devices powered by the WGSW-2620PV and 

keep the network alive for the data transmission. The UPS-400 supports 400 watts of 

electrical power, once the AC power shut off, the UPS-400 then take over as the 

UPS power supply for WGSW-2620PV and keep the switch and the connected 

powered devices working.   

1.2 Packet Contents 

Your UPS-400 carton should contain following items:   

。 

The UPS Redundant Power 

。 

Power Cord 

。 

DC 48V Power Connector 

。 

RS-232 Console Cable 

。 

Rack Mount Kit 

。 

4 Robber feet   

。 

This User’s Manual 

If any item is found missing or damaged, please contact your local reseller from 

whom you purchased your UPS. 

Summary of Contents for UPS-400

Page 1: ...400 Watts UPS Redundant Power for WGSW 2620PV UPS 400 User s Manual...

Page 2: ...incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursua...

Page 3: ...2 Rev 1 0 December 2005 Part No 2011 A92340 000...

Page 4: ...4 Specifications 5 1 5 Software Feature 5 1 6 Product Outlook 6 1 7 LED Definition 6 Chapter 2 Installation 7 2 1 Hardware Installation 7 2 2 Battery Charge up 8 2 3 Install with WGSW 2620PV 8 Chapte...

Page 5: ...he other is the 48V DC by the UPS 400 Uninterruptible Power Supply Once both the AC and the DC are used the UPS 400 take the UPS 400 as the redundant power supply for power backup to prevent the power...

Page 6: ...ut 100 240V AC 50 60Hz 5A max Power Consumption 500 watts system Output DC Power 48V DC 400 watts output capability Output DC Connector Mini Fit 8 Pin ATX Right 4 pins for GND left 4 pins for 48VDC RS...

Page 7: ...ng device internal heat sink temperature System testing Provide system testing command through RS 232 for battery status 1 6 Product Outlook Front Panel Rear Panel 1 7 LED Definition AC Input Lights t...

Page 8: ...attached to the package Figure 2 1 shows how to attach brackets to one side of the UPS Figure 2 1 Attach brackets to the UPS Caution You must use the screws supplied with the mounting brackets Damage...

Page 9: ...00 The system is started up by a beep buss The AC input and the DC output LED then lighted up 3 There need 8 to 12 hours to charge up Please connect the power cord and wait for 8 hours before use 2 3...

Page 10: ...TE When the Managed Power Supply unit AC power is down the internal UPS can provide the power to connected POE switch for 30 seconds in full power consumption and 30 minutes in only switch basic opera...

Page 11: ...2620PV and the data loading on the network 3 2 UPS Status Monitoring The UPS 400 passes its status information to the WGSW 2620PV by the console cable To view the status from the web interface please...

Page 12: ...ged Battery 60 milliohms approx Maximum Discharge Current with Standard Terminals amperes 40 Maximum Short Duration Discharge Current amperes 75 Charge Retention Shelf Life At 68 Degrees F 20 Degrees...