background image

 

 

             

www.xpcc.com

 

|

 

©

 

2012

 

Xtreme

 

Power

 

Conversion

 

Corporation.

 

All

 

rights

 

reserved.

 

 

UNINTERRUPTIBLE

 

POWER

 

SUPPLY

 

(UPS)

 

 

 

 

 

S70

 

Line

Interactive

 

Low

 

Voltage

 

Tower

 

Models

 

 

USER

 

&

 

INSTALLATION

 

MANUAL

 

 

 

 

 

 

 

 

 

Summary of Contents for S70 Line?Interactive

Page 1: ...www xpcc com 2012 Xtreme Power Conversion Corporation All rights reserved UNINTERRUPTIBLE POWER SUPPLY UPS S70 Line Interactive Low Voltage Tower Models USER INSTALLATION MANUAL ...

Page 2: ...intenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Sup...

Page 3: ...e UPS maintains constant voltage isolating critical load output and cleaning the utility AC power Line Interactive Technology A line interactive technology UPS provides basic power protection and Automatic Voltage Regulation AVR to the load when AC input power is available When AC input power is unavailable the line interactive UPS will switch to batteries to supply the load with power In the even...

Page 4: ...MANUAL V2 Xtreme Power Conversion XPC Corporation 4 When AC input power returns the UPS automatically begins supplying the load with power through the AVR circuit The charger circuit provides recharge for the batteries ...

Page 5: ...S70 SERIES USERS MANUAL V2 Xtreme Power Conversion XPC Corporation 5 ...

Page 6: ...MANUAL onversion X Initial Sta nstallation i nothing insid torage n a protecte te air flow P cm to avoid temperature cifications fo XPC Corporat artup inspect the u de has been d area that i Place the UP interference e and humid r details tion unit and pac damaged is free of exc PS away from e DO NOT o ity is outside 6 ckaging to cessive dust m other units operate the e the specifie V2 s at ed ...

Page 7: ...the devices connected to the UPS will be protected by the UPS unit Connect Modem Phone for Surge Protection S70 1000 1500 2000 models only Connect a single modem phone line into surge protected IN outlet on the back of the UPS unit Connect from OUT outlet to the computer with phone line cable Connect Communication Cable To allow for unattended UPS shutdown start up and status monitoring connect on...

Page 8: ...serviceable parts inside Refer servicing to qualified service personnel CAUTION Non isolated Battery supply Risk of electric shock battery circuit is not isolated from AC input hazardous voltage may exist between battery terminals and ground Test before touching WARNING Unit intended for installation in a controlled environment CAUTION Do not dispose of batteries in a fire the battery may explode ...

Page 9: ...supervised by personnel with knowledge of batteries and the required precautions Keep unauthorized personnel away from batteries The instructions contained within this safety manual are deemed important and should be closely followed at all times during installation and follow up maintenance of the UPS and batteries ...

Page 10: ...ds when the AC input is normal The UPS is overloaded Remove some of the load from the output of the UPS When power fails backup time is shorter than expected The UPS is overloaded Remove some of the load from the output of the UPS Battery voltage is too low Charge the UPS at least 8 hours Battery defect possibly due to high environmental temperature or improper operation of the battery Replace the...

Page 11: ...4 6 hours to 90 capacity PHYSICAL Dimensions W x D x H Product Dimensions 3 9 x 11 3 x 5 6 in 100 x 287 x 142 mm 5 7 x 13 8 x 6 3 in 146 x 350 x 160 mm 5 7 x 15 6 x 8 1 in 146 x 397 x 205 mm Shipping Dimensions 5 5 x 13 1 x 8 7 in 140 x 332 x 220 mm 7 5 x 17 4 x 10 0 in 190 x 442 x 254 mm 9 1 x 19 3 x 11 3 in 230 x 490 x 287 mm Product Weight 9 5 lbs 4 3 kg 10 8 lbs 4 9 kg 17 6 lbs 8 0 kg 24 5 lbs...

Page 12: ...dible Noise 40dB Altitude 11 500 ft 3500 m above sea level INDICATORS ALARMS LCD Display AC Mode Battery Mode Load Level Battery Level Input Voltage Output Voltage Overload Fault Low Battery Battery Mode Alarm sounds every 10 seconds Low Battery Alarm sounds every second Overload Alarm sounds every 0 5 seconds Battery Replacement Alarm sounds every 2 seconds Fault Alarm sounds continuously ...

Page 13: ...will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number RMA If you are returning the UPS to Xtreme Power for service please follow these procedures 1 Pack the UPS in its original packaging If the original packaging is no longer available as ...

Page 14: ... the equipment is repaired or modified by anyone other than XPC Corporation or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating m...

Page 15: ...roducts The Initial Purchaser of this Product is protected for the term of the XPC Limited Warranty against certain losses caused by a Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provided below This policy applies only to the original purchaser of the Product If the Product is transferred or sold to an...

Page 16: ... the Connected Equipment has not been operated in compliance with the instructions and manuals of its manufacturer vendor 7 This policy is null and void if XPC determines in its sole discretion that the Product has been tampered with or altered in any way What is Not Covered Under the Load Protection Policy The following damage is not covered by this Policy 1 Restoration of lost data and reinstall...

Page 17: ...nce of damage from a Power Disturbance XPC will request that all Connected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to you for either the cost of repair of the Connect...

Page 18: ...S70 SERIES USERS MANUAL V2 Xtreme Power Conversion XPC Corporation 18 For more information about Xtreme Power Conversion Corporation products services or UPS Selector sizing please visit www xpcc com ...