1.3 Features 

。 

Build-in UPS and DC 48V 400 watts power supply 

。 

Provide RS-232 interface for power monitor 

。 

AC input power voltage, frequency, current status monitoring 

。 

DC 48V power status, output current, output voltage status monitoring 

。 

UPS battery level, battery status, load status monitoring 

。 

Buzzer for system event 

。 

Slim size and all in one package with power and UPS 

。 

Provide DC 48V for Power over Ethernet equipment 

。 

1 U height design 

。 

19” rack mountable 

。 

FAN detect through RS-232 

1.4 Specifications 

Model 

UPS-400 

Power Input 

100~240V AC, 50/60Hz, 5A max. 

Power Consumption 

500 watts (system) 

Output DC Power 

48V DC, 400 watts output capability   

Output DC Connector 

Mini Fit (8-Pin ATX)   

(Right 4 pins for GND, left 4 pins for +48VDC) 

RS-232 

DB-9 female on rear side for power monitor 

Buzzer 

Buzzer for no AC, over load, fan fail and battery low events 

FAN 

2 fans with fan detection 

LED Indicators 

1 AC active, 1 Fault (fan fail, temperature over, over load) 

and 1 DC power (active, battery work, battery low) 

Operation Environment 

0 to 45 Degree C, 10%~95% RH 

Storage Environment 

-40 to 70 Degree C, 95% RH 

Dimension (W x D x H) 

440 x 223 x 44 mm 

EMI 

FCC Class A, CE 

Safety UL, 

cUL, 

CE/EN60950 

1.5 Software Feature 

。 

Power monitoring – 

AC input power status (voltage, frequency, AC 

Summary of Contents for UPS-400

Page 1: ...400 Watts UPS Redundant Power for WGSW 2620PV UPS 400 User s Manual...

Page 2: ...incorrect misleading or incomplete we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursua...

Page 3: ...2 Rev 1 0 December 2005 Part No 2011 A92340 000...

Page 4: ...4 Specifications 5 1 5 Software Feature 5 1 6 Product Outlook 6 1 7 LED Definition 6 Chapter 2 Installation 7 2 1 Hardware Installation 7 2 2 Battery Charge up 8 2 3 Install with WGSW 2620PV 8 Chapte...

Page 5: ...he other is the 48V DC by the UPS 400 Uninterruptible Power Supply Once both the AC and the DC are used the UPS 400 take the UPS 400 as the redundant power supply for power backup to prevent the power...

Page 6: ...ut 100 240V AC 50 60Hz 5A max Power Consumption 500 watts system Output DC Power 48V DC 400 watts output capability Output DC Connector Mini Fit 8 Pin ATX Right 4 pins for GND left 4 pins for 48VDC RS...

Page 7: ...ng device internal heat sink temperature System testing Provide system testing command through RS 232 for battery status 1 6 Product Outlook Front Panel Rear Panel 1 7 LED Definition AC Input Lights t...

Page 8: ...attached to the package Figure 2 1 shows how to attach brackets to one side of the UPS Figure 2 1 Attach brackets to the UPS Caution You must use the screws supplied with the mounting brackets Damage...

Page 9: ...00 The system is started up by a beep buss The AC input and the DC output LED then lighted up 3 There need 8 to 12 hours to charge up Please connect the power cord and wait for 8 hours before use 2 3...

Page 10: ...TE When the Managed Power Supply unit AC power is down the internal UPS can provide the power to connected POE switch for 30 seconds in full power consumption and 30 minutes in only switch basic opera...

Page 11: ...2620PV and the data loading on the network 3 2 UPS Status Monitoring The UPS 400 passes its status information to the WGSW 2620PV by the console cable To view the status from the web interface please...

Page 12: ...ged Battery 60 milliohms approx Maximum Discharge Current with Standard Terminals amperes 40 Maximum Short Duration Discharge Current amperes 75 Charge Retention Shelf Life At 68 Degrees F 20 Degrees...

Reviews: