Error Codes in the UltraRes Control Software
Planar UltraRes User Manual
143
Error Code
Meaning
Display Behavior and Solution
DC Power Supply
Failure
One of the DC-DC converters on
the main board of the display has
failed.
The display will not start up if this
occurs.
Solution
: The main board needs to
be replaced.
FPGA Initialization
Failure
One of the FPGAs on the main
board did not start up correctly.
There are two possible causes: one
of the FPGAs has corrupt code or is
damaged.
Solution
: First check the FPGA
status LEDs on the main board. If
one is not blinking, that FPGA
didn’t start up. The FPGA code may
need to be programmed again.
Solution
: If reprogramming an
FPGA doesn’t work, it is likely the
FPGA is damaged. If this is the case,
the main board needs to be
replaced.
Calibration
EEPROM Failure
The main board could not
communicate with the calibration
EEPROM.
It is likely that the calibration
EEPROM cable is disconnected.
Solution
: Connect the EEPROM
cable.
Summary of Contents for UltraRes
Page 1: ...Planar UltraRes User Manual...
Page 11: ...European Disposal Information...
Page 48: ...Connecting Sources Planar UltraRes User Manual 48 5 After this is done click Keep Changes...
Page 122: ...Signal Compatibility Planar UltraRes User Manual 122...
Page 131: ...84 UltraRes Touch Side Views Planar UltraRes User Manual 131 84 UltraRes Touch Side Views 8...
Page 132: ...84 UltraRes Touch Rear View Planar UltraRes User Manual 132 84 UltraRes Touch Rear View...
Page 139: ...98 UltraRes Touch Side Views Planar UltraRes User Manual 139 98 UltraRes Touch Side Views...
Page 140: ...98 UltraRes Touch Rear View Planar UltraRes User Manual 140 98 UltraRes Touch Rear View...