PL-AUDIO PowerPac 5002 User Manual Download Page 8

Mains connection

The device may only be connected to an electrical installation that complies with the VDE regulations DIN VDE 0100.        
The electrical installation must be equipped with a residual current circuit breaker (RCD) with> 30mA rated residual   
current.

The devicve is supplied with dangerous mains voltage (>50 Volt AC). Therefore never intervene on the device on      
yourself! There is a risk of electric shock! Connection cables has to be protected against crushing, tensile load and     
bending. Cables and wires are to be laid or secured in such a way that no one can trip over it or may fall.

Damaged Mains-Power cables

must not be used and should immediately be rendered unusable against further use,        

e.g. cut off both plugs.
The device is powered by a Neutrik Powercon® connector. In contrast to a plug-in device (such as a safety plug), the
Powercon® plug-in connection must not be plugged in or disconnected under load and also not under voltage! The 
consequences are stuck or burned-out contacts and the resulting loose contacts lead to failures or even destruction
of the electronics or even the risk of fire. You should therefore only switch the device ON or OFF using the
2-pole power switch.
The mains plug may only be connected to an earthed safety socket with the associated mains connection cable. If
extension cables are used, it must be ensured that the wire cross-section is dimensioned and approved for the
power supply required for the device! Make sure that the mains voltage of the socket corresponds to the permissible
voltage values

​​in 

this manual.

The power supply of the amplifier is equipped with an intelligent mains voltage detection. It allows worldwide
operation on all power grids. After switching on, the electronics check the mains voltage and switches the power 
pack to the correct voltage range 115V AC or 230V AC.

If a three-phase current generator is used at events on which the device is to be operated, the correct mains
voltage must be checked before connecting the amplifier! In the event of faulty three-phase power supplies without
a neutral conductor, a so-called neutral point shift can result in up to 400Volt being applied to the protective
contact sockets. This overvoltage leads to the destruction of the electronics in the amplifier.

The device has a blind cover (8) over the existing Powercon®-IN (see page 7, item 7). This is provided for the optional 
possibility of discrete power supply of the second output stage block via a second Powercon® IN. In the original 
delivery condition, the two separate amplifier blocks are supplied with power via the lower located Powercon® IN. 
This option of redundant power supply for both amplifier blocks can be retrofitted at the factory if required, and 
thus enables the amplifier blocks to be operated on different current phases (e.g. block 1 to L1, block 2 to L2, ...).

Best option is to connect the PowerPac 5002 to its own circuit with a 16A fuse (characteristic curve C). Please refer
to the technical data for the power consumption in the different operating states. The control LED on the front next
to the respective gain control serves to check the switching status of each individual block (page 7, upper figure, 
number 2). The central control LED (number 5) lights up as soon as at least one block is switched on.

The device corresponds to protection class 1.
In the event of a thunderstorm or danger, pull the power plug out of the socket immediately.

To avoid ground loops, we recommend using symmetrical signal routing and the power distribution in the so-called
star point earthing, which means, all ground connections meet at one single point. 

Never interrupt the contact to the protective conductor (e.g. by cutting off the protective conductor, disconnecting
the connection to the protective conductor through insulation, etc.), because in the event of a defect this increases
the risk of a electric shock over the metal housing.

8

USER MANUAL PowerPac 5002

© PL-Audio GmbH & Co.KG | Siegener Straße 6 | 57482 Wenden | www.pl-audio.de  Version: October 2021  V 1.0 

Summary of Contents for PowerPac 5002

Page 1: ...Pac 5002 AMPLIFIER powerful 2 Channel Amplifier Handmade in Germany impressive output power 2 x 2500 Watt at 4Ohm Dual Monoblock Construction 2 separated Powerblocks Input and Peaklimiter audiophile s...

Page 2: ...elivery technical data overview 5 Detailed product description 5 Technical data detailed 6 Construction and control interface 7 Mains connection 8 Usage on a mains power generator XLR and speaker conn...

Page 3: ...ing water high humidity heat and direct sunlight Do not place any objects filled with liquids such as drinking water glasses on the product The heat generated by the amlipier modules must be dissipate...

Page 4: ...UPS systems and faulty feeds into the device Furthermore PL AUDIO does not recognize any warranty or guarantee claims for any direct or indirect damage caused by installation configuration manipulatio...

Page 5: ...pass through for signal forwarding to additional components allowing the comfortable set up of high powered multi channel systems 5 2 CHANNEL CLASS D AMPLIFIER 2 X 2500 W INPUTLIMITER AND PEAKLIMITER...

Page 6: ...ge Automatic voltage detection AC Range 1 120V 85V 138V AC US Voltage AC Range 2 230V 170V 265V AC Europe Voltage Frequency range 45Hz 65Hz Power consumption at 230V Standby 6 Watt 0 026A Idle 2 x 27W...

Page 7: ...nected lights up if min one amplifier module is switched on Nr Element 1 XLR Input symmetric signal 2 XLR Out symmetric signal signal pass through 3 Ground Lift Switch 4 Air ventilation fan warm air i...

Page 8: ...ce is to be operated the correct mains voltage must be checked before connecting the amplifier In the event of faulty three phase power supplies without a neutral conductor a so called neutral point s...

Page 9: ...possibly damaging noises in the connected loudspeakers Also turn the gain controls on the front to the left Make absolutely sure that any upstream crossover or any upstream limiter is set correctly D...

Page 10: ...power amplifier has a gain control on the front panel for each power amplifier block To be on the safe side turn it all the way to the left BEFORE switching on When you have made all connections turn...

Page 11: ...l impedance of 8 ohms 2500W per amplifier block The signal assignment to the midrange and tweeter in the tops monitors is done by a crossover built into the tops monitors In the example above the Thru...

Page 12: ...ms or one subwoofer with 4 ohms per amplifier block via the lower Speakon sockets with circuitry 2 2 circuitry of the subwoofer depends on the manufacturer it may be necessary to connect to the upper...

Page 13: ...grated crossover and 8Ohm 2500W per power amplifier block The signal assignment to the subwoofer as well as the midrange and tweeter in the tops is handled by a passive crossover built into the subwoo...

Page 14: ...ls We have therefore marked all devices affected by the ElektroG with the crossed out garbage can This symbol indicates that it must not be disposed of with household waste But also not known signed o...

Reviews: