PKP DS04.1 Instruction Manual Download Page 16

Dimensions:

                         

DS04 with flow indicator

Contacts:

The contact opens/changes, if the flow level has fallen under the
adjusted value

* Exact max. switching capacity: see ATEX documents

ATEX-designations:

Contacts 3ST5, 3ST6, 3UT5, 3UT6:

ATEX II 2 G Ex mb II T6 & ATEX II 2 D Ex tD A21 IP67 T80 °C
ATEX II 2 G Ex mb II T5 & ATEX II 2 D Ex tD A21 IP67 T100 °C
(with cable connection, Standard 2 m only)

Dimensions:

Type

Dimensions [mm] 

Weight

appr. [g]

SW D 

D1

B.

01 - 04

27  30  47  71

1/4

3/8

1/2

14

19

19

131

800/900

05

27

32

30

35

47

47

71

71

1/2

3/4

19

17

146

174

800/850

960/1010

06

07

08

34

40

50

40

40

40

57

57

67

76

76

81

3/4

1

1

18

19

20

152

156

200

1350/1400

1050/1100

2750/2800

PKP Prozessmesstechnik GmbH

Borsigstr. 24 • D-65205 Wiesbaden

S

 +49 (0) 6122-7055-0 • 

T

 +49 (0) 6122 7055-50

 [email protected] •   www.pkp.de

Switching capacity

Type

Size

Contact function

Angle plug IP65

M12x1 plug IP67

cable connection (1 m) IP67

DS04.1

DS04.1A

DS04.2
DS04.3
DS04.4

1/4“
3/8“
1/2“
3/4“

1“

1 = N/O

250 V / 3 A / 100 VA

2 = SPDT

250 V / 1,5 A / 50 VA, min. load: 3 VA

2X = SPDT for SPS

250 V / 1 A / 60 VA

-/-

-/-

3ST5 = Ex-N/O, T5*
3ST6 = Ex-N/O, T6*

-/-

-/-

250 V / 2 A / 60 VA (2 m cable)

3UT5 = Ex-SPDT, T5*
3UT6 = Ex-SPDT, T6*

-/-

-/-

250 V / 1 A / 30 VA, 

min load: 3 VA (2 m cable)

Summary of Contents for DS04.1

Page 1: ...anual DS04 All Metal Variable Area Flowmeter and Switch High Pressure Version PKP Prozessmesstechnik GmbH Borsigstra e 24 D 65205 Wiesbaden Nordenstadt Tel 49 0 6122 7055 0 Fax 49 0 6122 7055 50 Email...

Page 2: ...improper use non observance of this operating manual use of insufficiently qualified personnel and unau thorized modification of the device Proper Usage The variable area flowmeters of the DS04 series...

Page 3: ...mount the devices correctly Qualified personnel are persons who are familiar with assembling installation placing in service and operating these devices and who are suit ably trained and qualified Inw...

Page 4: ...damage to the flow monitor or the system a process connection suitable for the device must be provided by the customer check connection size and screw in depth use suitable sealants liquid sealants da...

Page 5: ...e case of liquid media take appropriate steps to ensure that the device is ven ted to ensure measuring accuracy the device must always be completely filled with medium vent the pipeline If there are a...

Page 6: ...ower The Reed contact integrated in the switching unit is very sensible to electrical over load Danger of overload is given by the following applications inductive load capacitive load lamp load Induc...

Page 7: ...directly connected to the input terminals of a PLC without problems RC Circuits as protective measures Boucherot cell Snubber In practice the following values of resistor capacitor cells give good re...

Page 8: ...re that the device is grounded via the pipeline This prevents dangerous potential differences from occurring Switching capacity of contacts Switching capacity Type Size Contact function Angle plug IP6...

Page 9: ...or acc to EN 175301 803 Normally Open NOC Change Over COC Switch position under no flow condition Switch position under no flow condition The ground pin is not used The ground pin is not used DS04 Ins...

Page 10: ...der no flow condition Switch position under no flow condition Switching contact with cable The individual cores of the cable are numbered according to the following connection dia gram Normally Open N...

Page 11: ...2 Slide the switch contact to the flow value to be monitored Make sure that the arrow on the switch contact label is in exact alignment with the desired flow value on the body scale 3 Re tighten the...

Page 12: ...Switch contact is permanently switched Flow is too high or the switch contact is set too low Reduce the flow Adjust the switch contact to a higher flow rate Use the device at another measuring range...

Page 13: ...s and circumstances Maintenance work Visual inspection for dirt soiling Visual inspection for free movement of float Visual inspection for leaks from the device Check function of switch contact For de...

Page 14: ...s following the float position indicates the flow rate on a scale A Reed contact is mounted outside the meter in a sealed housing When the float reaches the position of the Reed contact the switch wil...

Page 15: ...1 4 1N 1 4 NPT 1A G 3 8 1AN 3 8 NPT 2 G 1 2 2N 1 2 NPT 3 G 3 4 3N 3 4 NPT 4 G 1 4N 1 NPT Material 1 brass nickel plated 2 stainless steel 1 4571 Scale 1 for water 2 for air at 1 bar abs 20 C Measurin...

Page 16: ...800 900 05 27 32 30 35 47 47 71 71 1 2 3 4 19 17 146 174 800 850 960 1010 06 07 08 34 40 50 40 40 40 57 57 67 76 76 81 3 4 1 1 18 19 20 152 156 200 1350 1400 1050 1100 2750 2800 PKP Prozessmesstechnik...

Page 17: ...r operating densities deviating from the specified specifications increase the specified measuring error Special scales for different media and operating conditions are available on request The specif...

Reviews: