![Pkm S7-60 ABTH Instruction Manual Download Page 39](http://html1.mh-extra.com/html/pkm/s7-60-abth/s7-60-abth_instruction-manual_1561270039.webp)
39
Explications:
(1) measurement of air flow
Range hoods with a maximum air flow, which
is more than 650 m
3
/h at an available setting,
must automatically change to an air flow,
which is max. 650 m
3
/h.
(2) Airborne acoustical noise
According to dB(A) re 1 pW.
To determine the results, and in accordance with the requirements in relation to
the labelling of energy-related products and with regard to ecodesign requirements,
the following calculation and measurement methods were applied:
Directive of the European Parliament and of the Council 2010/30/EU;
REGULATION NO 65/2014.
Directive of the European Parliament and of the Council 2009/125/EC;
REGULATION NO 66/2014.
EN 50564 - Electrical and electronic household and office equipment.
Measurement of low power consumption
EN 60704-2-13 - Household and similar electrical appliances. Test code for the
determination of airborne acoustical noise. Particular requirements for range
hoods.
EN 61591 - Household range hoods and other cooking fume extractors -
Methods for measuring performance.
6.2 Relevant data for installation
S7-60 AWTH/S7-60 ABTH
Voltage/frequency
AC 220-240V/50Hz
Grease filter/material/dishwasher-proof
1
aluminium
Carbon filter *
2*CF 110
Exhaust hose
Installation material
Recirculation kit
Instruction manual
Telescopic chimney extractable from-to
40.00-78.00 cm
Installation with ventilation stack or air duct
outwards
Wall penetration = 150 mm Ø
Drilling = approx. 153 mm Ø
Dimensions H*W*D in cm
76.00-114.00*60.00*39.00
Weight net/gross in kg
14.00/17.00