background image

 1  INFORMATION ON THIS DOCUMENT

1.1 Function

These operating instructions provide information on installation, connection and safe 

use for the following articles: 

FD 

••••-M2-EX7, FL ••••-M2-EX7, FM ••••-M2-EX7.

1.2 Target audience

The operations described in these operating instructions may be performed only by 

personnel who are qualified to install devices in ATEX environments with explosion 

hazards, who are fully capable of understanding them, and who possess the technical 

qualifications  required  for  operating  the  machines  and  plants  in  which  the  safety 

devices are to be installed.

1.3 Application field

These instructions apply exclusively to the products listed in paragraph Function, and 

their accessories.

1.4 Original instructions

The Italian language version is the original set of instructions for the device. Versions 

provided in other languages are translations of the original instructions.

 2  SYMBOLS USED

 

This symbol indicates any relevant additional information

 

Attention:  Any  failure  to  observe  this  warning  note  can  cause  damage  or 

malfunction, including possible loss of the safety function.

 3  DESCRIPTION

3.1 Device description

The device described in these operating instructions is a position switch composed of a 

metal housing containing electrical contacts driven by actuator heads.

3.2 Intended use of the device

- The device described in these operating instructions is designed to be applied to indu-

strial machines with or without risk of explosion.

- The direct sale of this device to the public is prohibited.
- The use of the device for purposes other than those specified in these instructions is 
prohibited.

-  Any  use  other  than  as  expressly  specified  in  these  instructions  shall  be  considered 
unintended by the manufacturer. 

- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications 
to it;
b) using the product in a field of application other than as described in paragraph 
TECHNICAL DATA.

 4  INSTALLATION INSTRUCTIONS

 Attention: Installing a protective device is not sufficient to ensure operator safety 

or  compliance  with  machine  safety  standards  or  directives.  Before  installing  a  pro

-

tective device, perform a specific risk analysis in accordance with the key health and 
safety requirements in the Machinery Directive. The manufacturer guarantees only the 

safe functioning of the product to which these operating instructions refer, and not the 

functional safety of the entire machine or entire plant.

 For assembly and operating instructions of articles F•

 

••93-M2-EX7, 

F

 

••99-M2-

EX7, 

F

 

••R2-M2-EX7, 

F

 

••95-M2-EX7, 

F

 

••78-M2-EX7•, 

F

 

••83-M2-EX7, 

F

 

••84-M2-

EX7, please refer to the operating instructions for the versions of the article to be used 
in standard environments (with no explosion hazard).

4.1 General conditions

- Please read these operating instructions carefully before installation to ensure proper 
operation of the device and the safety of the application. Please contact our Technical 
Office (see paragraph SUPPORT) for any remaining issues or questions.

- The general engineering rules, specific national regulations and the applicable directi-
ves must be observed when selecting and using the devices.

- The utilization implies compliance and knowledge of the ATEX Directive 2014/34/EU.
For use in potentially explosive areas, the installation rules stipulated by the technical 

rules of the area for which the device is designed must be observed.

- Failure to comply with the requirements of the operating instructions or incorrect use of 

the device during operation can lead to the damage of the device and the loss of the sa-

fety function performed by the device itself. This will result in termination of the warranty 
on the item and will release the manufacturer from any liability.
- Store the products in their original packaging, in a dry place with temperature between 
-40°C and +70°C

 Attention: Before proceeding with the installation of the device, ensure that the 

markings on the product are compatible with the ATEX rating of the site where the 

device will be used. Failure to comply with this requirement can cause serious injury 
to persons, including death, and/or serious damage to property.

Devices

Markings

Certificate

FD ••••-M2-EX7

 

FL ••••-M2-EX7

 

FM ••••-M2-EX7

 

I M2 Ex ia I Mb

II 2G Ex ia IIC T6 Gb

TUV IT 21 ATEX 061
TUV IT 21 ATEX 076 Q

 Attention: 

These devices must be introduced into an intrinsically safe system 

containing only components that do not compromise the intrinsic safety level required 
by the class of protection. Each device must only be used:
- for a single intrinsic safety system, on switches with contact blocks 20, 21, 22, 28, 
29, 30, 33, 34, 66, 67.
- for one or two intrinsic safety systems, on switches with contact blocks 5, 6, 7, 8, 9, 
10, 11, 12, 13, 14, 15, 16, 18, 37.

Example of code structure: 

FD 2038-M2-EX7

Actuator type
Contact block type
Housing type

4.2 Instruments

Normal screwdrivers and tool keys are required for the installation of these devices.

4.3 Electrical parameters

 Attention: The electrical parameters are indicated on the product, in these ope-

rating instructions and on its certificate and must be strictly observed.
- Maximum switching voltage: 30 Vdc
- Maximum switching current: 2.5 A

4.4 Installation

 

The device can be fastened in any position.

Always use the same number of screws as the number of holes on the housing when 

mounting the device. Install the screws with medium resistance thread locker with the 

number of threads engaged being equal to or greater than the screw diameter. The 

device must never be fixed with fewer screws than holes available on the housing.

 

The  diameter  and  property  class  of  the  screws  must  be  suitable  for  the  expected 

loads. Tighten with a torque of between 2 and 3 Nm.

- Tighten the cover, head and lever screws with a torque of between 0.8 Nm and 1.2 

Nm.

- Do not exceed the maximum actuation travel.

4.5 Installation requirements

- Do not perform any operation inside the device when there is voltage.

- Maintenance in the ambient temperature range (-20° C to +60° C) and compliance 

with the instructions provided with the device are requirements for proper operation.

- During installation and connection, make sure that the conductors are correctly po

-

sitioned and clamped in the terminals.

- Tighten the internal conductor terminals with a torque of between 0.6 and 0.8 Nm.

- Always use a cable gland suitable for a potentially explosive use environment and 

for the cable section. Pursuant to EN 60529, the cable gland must have a degree of 

protection IP at least equal to or greater than the IP of the device.

- The cable glands must be cable glands for Ex equipment or Ex components and 

must not invalidate the specific features of the device's protection type

- To connect the external ground cable, use an eyelet terminal.

- Do not disassemble the device. If it is necessary to adjust the head of the device, 

reposition the head in the base with greatest care after adjusting it.

- At the end of the wiring, check that no contaminating element has been introduced 

inside the device.

- Before closing the device cover, verify the correct positioning of the gaskets.

- Verify that the electrical cables, wire-end sleeves, cable numbering systems and any 

other parts do not obstruct the cover from closing correctly or if pressed between them 

do not damage or compress the internal contact block.

- During and after the installation do not pull the electrical cables connected to the 

device. If excessive tension is applied to the cables (which are not supported by an 

appropriate cable gland), the contact block of the device may be damaged.

- When the wiring is complete and before activation, verify that the device identification 

code corresponds both on the cover and on the housing.

- The general installation and assembly requirements described in EN 60079-14 must 

be complied with.

4.6 Testing

No test period is required when installation is performed by qualified personnel.

 5  INSTRUCTIONS FOR PROPER USE

5.1 Installation

- Do not modify the device for any reason.

- Do not stress the device with bending or torsion.

- Do not exceed the tightening torques specified in the present operating instructions.
- If the device performs an operator protection function in accordance with EN ISO 14119, 
improper installation or tampering can cause serious injury to persons and even death.
- These devices must not be bypassed, removed, turned or disabled in any other way.

- If the machine where the device is installed is used for a purpose other than that speci-

fied, the device may not provide the operator with efficient protection.
- The safety category of the system (according to EN ISO 13849-1), including the safety 

device, 

also depends on the external components connected to it and their type.
- Before installation, make sure the device is not damaged in any part.
- Before installation, ensure that the connection cables are not powered.
- Avoid excessive bending of connection cables in order to prevent any short circuits or 

power failures.
- Do not paint or varnish the device.
- Do not drill the device.

- Do not use the device as a support or rest for other structures, such as raceways, sliding 

guides or similar.

- Before commissioning, make sure that the entire machine (or system) complies with all 

applicable standards and EMC directive requirements.

- The switch fitting surface must always be smooth and clean.
- The documents necessary for a correct installation and maintenance are always availa

-

ble in the following languages: English, French, German and Italian.
- Should the installer be unable to fully understand the documents, the product must not 
be installed and the necessary assistance may be requested (see paragraph SUPPORT).
Always attach the following operating instructions to the manual of the machine in which 

the device is installed.

3/10

Pizzato Elettrica Srl

via Torino, 1
36063 MAROSTICA (VI)

ITALY

e-mail:  [email protected]
web site:  www.pizzato.com

Phone:   +39.0424.470.930
Fax:  

+39.0424.470.955

ZE FOG302A21-EU

Summary of Contents for FD-M2-EX7 Series

Page 1: ...za intrinseca prevista per la propria classe di protezione Ogni dispositivo deve essere usato solo per un singolo sistema a sicurezza intrinseca per interruttori con unità di contatto 20 21 22 28 29 30 33 34 66 67 per uno o due sistemi a sicurezza intrinseca per interruttori con unità di contatto 5 6 7 8 9 10 11 12 13 14 15 16 18 37 Esempio di struttura codice FD 2038 M2 EX7 Tipo di attuatore Tipo...

Page 2: ...ione di protezione delle persone vanno rispettate le seguenti pre scrizioni aggiuntive 1 L impiego implica comunque il rispetto e la conoscenza delle norme EN 60947 5 1 EN ISO 13849 1 EN 62061 EN 60204 1 EN ISO 14119 EN ISO 12100 2 Utilizzare solo dispositivi che riportino a fianco del codice il simbolo Il circuito di sicurezza va sempre collegato sui contatti di sicurezza NC contatti normalmente ...

Page 3: ...ormal screwdrivers and tool keys are required for the installation of these devices 4 3 Electrical parameters Attention The electrical parameters are indicated on the product in these ope rating instructions and on its certificate and must be strictly observed Maximum switching voltage 30 Vdc Maximum switching current 2 5 A 4 4 Installation The device can be fastened in any position Always use the...

Page 4: ...ety applications in general 3 Operate the device at least up to the positive opening travel indicated in the travel diagrams in the general catalogue 4 Operate the device with at least the positive opening force indicated in the general catalogue 5 7 Limits of use Use the device following the instructions complying with its operation limits and the standards in force The devices have specific appl...

Page 5: ...être insérés dans un système à sécurité intrinsèque constitué uniquement de composants qui ne réduisent pas la sécurité intrinsèque prévue pour leur propre classe de protection Chaque dispositif doit être utilisé uniquement pour un seul système à sécurité intrinsèque pour des interrupteurs avec des blocs de contact 20 21 22 28 29 30 33 34 66 67 pour un ou deux systèmes à sécurité intrinsèque pour ...

Page 6: ...ngueur de dénudage du câble ou de l embout isolé x doit être égale aux valeurs indiquées ci dessous Blocs de contact 20 21 22 28 29 30 33 34 Blocs de contact 5 6 7 8 9 10 11 12 13 14 15 16 18 37 66 67 7 mm 8 mm x x 5 6 Prescriptions supplémentaires pour les applications de sécurité ayant des fonctions de protection des personnes Toutes les prescriptions précédentes étant bien entendues il faut éga...

Page 7: ...nt donné les multiples possibilités d application et de connexion du dispositif les exemples et les schémas contenus dans le présent manuel sont purement descriptifs l utilisateur est tenu de s assurer que l application du dispositif est bien conforme à la réglementation locale Toute reproduction même partielle du présent manuel sans une autorisation écrite de Pizzato Elettrica est interdite 2021 ...

Page 8: ...ch und Personenschäden bis zum Tod führen Geräte Beschriftungen Zertifikat FD M2 EX7 FL M2 EX7 FM M2 EX7 I M2 Ex ia I Mb II 2G Ex ia IIC T6 Gb TUV IT 21 ATEX 061 TUV IT 21 ATEX 076 Q Achtung Diese Geräte müssen in ein eigensicheres System eingebunden wer den dass ausschließlich aus Komponenten besteht die die für die entsprechende Schutzklasse vorgesehene Eigensicherheit nicht beeinträchtigen Die ...

Page 9: ...t Die Belastung muss innerhalb der Richtwerte für die jeweiligen elektrischen Einsat zkategorien liegen Das Gerät niemals bei anliegender Spannung öffnen Schutzsicherung oder gleichwertige Vorrichtung immer in Reihe mit den NC Si cherheits Kontakten verbinden Die folgenden minimalen und maximalen Querschnitte elektrischer Leiter für den Anschluss an die Schraubklemmen beachten Kontakteinheiten 20 ...

Page 10: ...ftung entstehen kann die über die im Hauptkatalog von Pizzato Elettrica angeführten Allgemeinen Verkaufsbedingungen hinausgeht Der Kunde Benutzer ist verpflichtet unsere Informationen und Empfehlungen sowie die entsprechenden technischen Bestimmungen vor der Verwendung der Produkte zu seinen Zwecken zu lesen Da das Gerät zahlreiche Anwendungen und Anschlussmöglichkeiten bietet sind die Beispiele u...

Reviews: