30
SM3 1003
Cycle time
Time of the last scan cycle of the program
(resolution 100
µ
S).
R
SM4 1004
Minimal cycle time
The minimal time found of the program scan
cycle (resolution 100
µ
S).
R
SM5 1005
Maximum cycle time
The maximum time found of the program
scan cycle (resolution 100
µ
S).
R
SM6 1006
Interval of timer interrupt n° 1
SM7 1007
Interval of timer interrupt n° 2
Word that defines the interval of the timer
interrupt.
The value can be set between 1 and 100 ms
(example:: SM6=1
1 ms, SM6=100
100 ms). For values of SM6 and SM7 not
between 1 and 100, the correspondent
interrupt is fixed to a default to 100 ms. At
startup they are both fixed to a default of 100
100 ms.
In the Ladder code of the two interrupts, it
is not allowed to use functions that
access the areas of EEPROM and MMC
.
R/W
SM8 1008
LCD contrast
LCD display contrast 0…100
0…100%.
At startup, if
SM1.0 = 1
, the value is
initialized to 50
50%, otherwise the
previously saved data is maintained.
R/W
SM9 1009
Minimal lamp time
LCD back-lighting display 1…1000
1…1000 minutes, 0
always lit.
At startup, if
SM1.0 = 1
, the value is
initialized to 0
always lit, otherwise the
previously saved data is maintained.
R/W
SM10 1010
Touch screen X
SM11 1011
Touch screen Y
Coordinates of the point of contact on the
R