This product is compatible with Nikon Creative Lighting System (CLS). It can function as either an optic 

wireless master or slave flash. As a master unit, it can control Nikon speedlights e.g. SB-900 and SB-910 

via wireless. As a slave unit, it can be controlled by wireless signals of Nikon speedlights e.g. SB-900 and 

pop-up flash commanders of Nikon cameras e.g. D7100/D7000/D800.

You can set up three slave groups for i-TTL autoflash shooting. With i-TTL autoflash, you can easily create 

various lighting effects. 

Any flash settings for the slave units on the master flash in i-TTL/Manual/RPT mode will be automatically sent to 

the slave units. So the only thing you need to do is to set the master unit for each slave group without any 

operation for the slave units at all during the shooting.

This flash can work in i-TTL/M/RPT/OFF flash modes when set as a master unit.

Positioning and Operation Range

1

.

Wireless Settings

You can switch between normal flash and wireless flash. For normal flash shooting, be sure to set the wireless 

setting to OFF.

Indoors

Outdoors

15

m

(

49

.

2

ft

)

10

m

(

32

.

8

ft

)

80°

8

m

(

26

.

2

ft

)

12

m

(

39

.

4

ft

)

Wireless Flash: Optic Transmission

● 

Even with multiple slave units, the master unit can control all of them via wireless.

● 

In this user manual, "master unit" refers to the camera flash on a camera and "slave unit" will be controlled by the 

Press <  

      

> button so that

 

<  

   

>

 

or

 <

 

    

RPT

 

are displayed on the LCD panel.

The backlight of LCD panel turns green now.

Master Unit Setting

Slave Unit Setting

Press <  

      

> button again

 

so that

 

<  

   

>

 

or

 <            > 

are displayed on the LCD panel.

The backlight of LCD panel turns orange now.

2

.

Setting Master Unit's Flash Mode

Press Function Button 4 

         

1

<

           

> to choose the group 

from M/A/B/C. Then, press 

Function Button 3 <

   

 

         

 > 

so that the master unit can 

work in 

OFF/i-TTL/M

 flash 

mode. Choose one of them as 

the flash mode of master unit.

3

.

Setting the Communication Channel

If there are other wireless flash systems nearby, you can change the channel IDs to prevent signal interference. The 

channel IDs of the master unit and the slave unit(s) must be set to the same.

Press Function Button 3 

         

1

            

> and turn the Select 

Dial to choose a channel ID 

from 1 to 4.

Press the <

SET

> button to 

2

confirm.

CH

Press the "MODE/Lock" button 

2

can change to RPT mode.

Wireless Flash: Optic Transmission

MODE

Summary of Contents for HYBRID360 ITTL

Page 1: ...5 AD36C0 00 For Nikon Powerful Portable TTL Flash PIXAPRO LTD 50 Popes Lane Oldbury West Midlands B69 4PA Tel 0845 872 7904 Web www essentialphoto co uk E mail customerservice essentialphoto co uk Com...

Page 2: ...y pack PowerPack Dual Output lithium 11 1V 4500mAh 0 05 4 5s recycling and 450 full power flashes Lightweight and portable even with power and accessories Wireless control With built in PIXAPRO 2 4GHz...

Page 3: ...ireless Flash Shooting with Manual Flash Wireless Flash Shooting Ratio 2 4G Transmission Other Applications Wireless Control Function Modeling Flash Auto Focus Assist Beam Assist Beam Setting Bounce F...

Page 4: ...f flashes Flash frequency 1 Flash tube 1 2 Protecting bag 1 3 Mini stand 1 4 Off camera adapter 1 5 Reflector 1 6 Power cable 1 7 Reflector diffuser 2 8 Instruction manual 1 The product can be used in...

Page 5: ...ted user manual Connecting to a PowerPack Name of Parts Connecting the Flash to a Camera 1 Loosen the locking ring on the mounting foot 2 Slip the mounting foot of the flash unit into the camera hotsh...

Page 6: ...the shutter button halfway then the flash display panel will show the second curtain sync icon When the camera is not set to Rear mode pressing the shutter button halfway will not light up the icon on...

Page 7: ...again to 3 confirm the setting Flash Mode M Manual Flash With stroboscopic flash a rapid series of flashes is fired It can be used to capture a multiple images of a moving subject in a single photogra...

Page 8: ...setting to OFF Indoors Outdoors 15m 49 2ft 10m 32 8ft 80 8m 26 2ft 12m 39 4ft Wireless Flash Optic Transmission Even with multiple slave units the master unit can control all of them via wireless In t...

Page 9: ...B C Check the communication 3 channel If the master unit and slave unit s are set to a different channel set them to the same channel Page 41 Position the camera and 4 flashes Position the camera and...

Page 10: ...ing functions master slave use the same setting method as i TTL autoflash The positioning and operation range can be found in the following pictures Set the master unit as i TTL mode to wirelessly fir...

Page 11: ...to make it easier for autofocus The beam will light up only when autofocus is difficult and get out as soon as the autofocus becomes correct If you find the auto focus assist beam does not light up t...

Page 12: ...ous flashes and then fire more flashes in short intervals the inner over temperature protection function may be activated and make the recycling time over 10 seconds If this occurs allow a rest time o...

Page 13: ...ort 5600 200k 75 95 220mm flash tube reflector not included 800g flash tube reflector not included If there is a problem refer to this Troubleshooting Guide The Camera Flash does not fire The camera f...

Reviews: