The following table lists the available and unavailable custom functions of this flash.
- 47 -
- 48 -
1. Press < MF/C.Fn > Button for 2 seconds or longer until C.Fn menu is displayed. The "Ver x.x" in the top-right
corner refers to the software version.
2. Select the Custom Function No.
●
Turn the Select Dial to select the Custom Function Signs.
3. Change the Setting.
●
Press <
SET
> button and the Setting No. blinks.
●
Turn the Select Dial to set the desired number. Pressing <
SET
> button will confirm the settings.
●
After you set the Custom Function and press <
MODE
> button, the camera will be ready to shoot.
4. In the C.Fn states, long press the “Clear”button for 2 seconds until "OK" is displayed on the panel, which means
C.Fn: Setting Custom Functions
Settings & Descriptions
ON
OFF
ON
OFF
ON
OFF
Off in 12 sec.
Always off
Always lighting
10 levels
Setting Signs
ON
OFF
ON
OFF
ON
OFF
12sec
OFF
ON
0~9
- → 0 → +
Functions
Auto power off
AF-assist beam
Beeper
Backlighting time
LCD contrast ratio
Custom Function Signs
APO
AF
BEEP
LIGHT
LCD
1. Over
-Heat
Protection
●
To avoid overheating and deteriorating the flash head, do not fire more than 75 continuous flashes in fast
succession at 1/1 full power. After 30 continuous flashes, allow a rest time of at least 75 minutes.
●
If you fire more than 75 continuous flashes and then fire more flashes in short intervals, the inner over-
temperature protection function may be activated and make the recycling time over 10 seconds. If this occurs,
allow a rest time of about 10 minutes, and the flash unit will then return to normal.
●
When the over-
heat
protection
has been activated
, is shown on the LCD display.
Number of flashes that will activate over-temperature protection:
Protection Function
Power Output Level
1/1
1/2(+0.3,+0.7)
1/4(+0.3,+0.7)
1/8(+0.3,+0.7)
1/16(+0.3,+0.7)
1/32(+0.3,+0.7)
1/64(+0.3,+0.7)
1/128(+0.3,+0.7)
Number of Flashes
75
100
150
200
300
500
1000
Meaning
A failure occurs on the recycling system so that the flash cannot fire.
Please restart the flash unit. If the problem still exists, please send this product to a maintenance center.
The system gets excessive heat. Please allow a rest time of 10 minutes.
The voltage on two outlets of the flash tube is too high. Please send this product to a maintenance center.
There are some errors occurred during the upgrading process. Please using the correct firmware
upgrade method.
LCD Panel
E1
E2
E3
E9
Number of flashes that will activate over-
heat
protection in high-speed sync triggering mode:
2. Other Protections
●
The system provides real-time protection to secure the device and your safety. The following lists prompts for your
reference:
Power Output
1/1
1/2(+0.3,+0.7);
1/4(+0.3,+0.7)
1/8(+0.3,+0.7);
1/16(+0.3,+0.7)
1/32(+0.3,+0.7);
1/64(+0.3,+0.7);
1/128(+0.3,+0.7);
Times
30
40
50
60
75
100