Measurement
Chamber
The measurement chamber of K900 consists of two chambers held
together by the manifold.
Inside the measurement chamber are the oval gears which, on turning,
generate electrical pulses which are processed by the microprocessor-
controlled electronic board.
By applying a suitable calibration factor (meaning a “weight” associated
with each pulse), the microprocessor translates the pulses generated by
the “fluid volume” rotation expressed in the set units of measurement,
displayed on the partial and total registers of the LCD.
All the meters are factory set with a calibration factor called FACTORY K
FACTOR equal to 1,000. For best meter performance the instrument can
be “calibrated”.
It is possible to return to factory calibration at any time.
Battery Housing
K900 is powered by two standard type 1.5 V batteries (size 1N) .
The battery housing is closed by a threaded watertight cap that can be
easily removed for quick battery change.
K900 components
1
LCD display
2
4
3
1
5
2
RESET button
3
Measurement
chamber
4
CAL button
5
Battery housing