10 INSTALLATION
Foreword
The "DELPHIN" dispensing system has been designed and arranged on a trolley
for ease of use and delivery.
Personnel
authorised
to install the
device
Installation must be performed exclusively by qualified and authorised staff.
They must:
- properly install all the components necessary for the pump to function prop-
erly;
- only use accessories that have been supplied with the system.
ATTENTION
The use of accessories that are unsuitable and were not provided with the system
is strictly prohibited. The Manufacturer shall not be held responsible for damag-
es caused to people, things or to the environment deriving from failure to meet
such instructions.
The distribution system DELPHIN is for professional use only.
The distribution system DELPHIN must be installed in a well lit place, in compli-
ance with the norms in force.
The DELPHIN dispensing system has been specifically designed for use in a dry
place. I
11 ASSEMBLING
DEPENDING ON THE MODEL, PROCEED WITH ASSEMBLY AS DETAILED IN THE M0431 SHEET
SUPPLIED WITH THE STATION.
12 OPERATION AND USE
Foreword
Directions on how to start and stop operation of the system are given below.
WARNING
To remove any substance residue or foreign matters from the pipes, wash the
system before putting it into operation.
To wash the system, follow the same dispensing procedures using demineralized
or deionized water and eventually rinse with ADBlue®
ATTENTION
During operation the motor may be hot: be careful.
WARNING
For the proper functioning of the system, allow a 10-minute stop for every 20
minutes of dispensing.
We recommend that the pump remains switched off whenever the system is
not in use.
ATTENTION
If ever the voltage is lagging, push the switch to the OFF position and return the
nozzle to its rest position
FLUID LEAKS CAN DAMAGE OBJECTS AND INJURE PERSONS.
Strictly observe the maximum capacity limits indicated on the dataplate.