14 LEAVING THE SYSTEM UNUSED FOR LONG PERIODS
OF TIME
Operations
to be carried
out
Whenever it is thought that the system will remain unused for at least 15 days,
it must be emptied in order to prevent the product from crystallising inside. This
shall be followed by a washing cycle.
15 WASHING THE DISPENSING SYSTEM
WHY TO
WASH
The dispensing system requires washing in order to remove product crystallisa-
tion which may damage the plant.
ATTENTION
Wear personal protective equipment (PPE) when performing the wash cycle.
Use only demineralised water to wash the system.
Following the same dispensing methods previously described (12.3 - DISPENS-
ING PHASES), wash the distribution system by aspirating about 20 liters of de-
mineralized water from a clean container and collecting the resulting mixture in
a different container, suitable for disposal.
PHASES OF
DELIVERY FOR
CLEANING
1 -
Press POWER button A.
2 -
Press the REFILL button B for 3 seconds.
3 -
Wait for the filling end.
4 -
Place the connector in the appropriate housing by screwing it clockwise.
Disposal
ATTENTION
By following the same modes of delivery described above, the dispensing system
can be washed by sucking up demineralised water from the clean container and
collecting the resulting mixture in a different disposable container.
Liquids resulting from washing must be disposed of in accordance with the laws
prevailing in the country of use.