To test the hi-limit, use a 2k

ς

 - 5 k

ς

 resistor to simulate a 230°F - 275°F temperature. This causes the elements to 

heat continuously until the hi-limit trips or the fryer is turned off. 

 

If testing with the computer, plug the resistor in at connector J41 behind the front panel. 

 

If testing with the back-up thermostat behind the door, plug the resistor in at connector J43 behind the front 

panel. 

If the switch does not trip between the prescribed limits, it is defective and should be replaced. Once tripped, the 

switch cannot be reset until the oil has cooled to approximately 375°F ±20°F. If the switch does not reset after oil 

has cooled, it is defective. 

Drain

 

Valve

 

and

 

Return

 

Valve

 

Switches

 

These switches are a magnetically operated proximity switches. When the BLUE drain valve handle is moved to 

the open position, the actuator moves away from the switch causing the switch to open. When the drain valve is 

closed, the switch closes.   

Opening the RED filter return valve handle closes the proximity switch, causing the “pump on” relay to be 

energized; the pump begins to pump. Closing the filter return valve handle opens the proximity switch, causing 

the relay to de-energize and the pump to stop pumping. These switches can be checked with a 

 meter. When the 

switch is closed, there should be continuity. The normal gap between the actuator and the sensor switch on the 

valve handle is 1/8 inch to 1/4 inch (3 mm to 6 mm). 

Transformer

 

The transformer is a multiple AC input voltage and 24 VAC output voltage. It can be checked by reading the 

input and output voltages. A quick check for 24 VAC is done at the relay board behind the front panel. The AC 

indicator is illuminated if the F1 fuse is good and the board is receiving 24 VAC. 

Elements

 

Each element has three coils. Check all the element coils out of circuit with an 

 meter. The resistance should 

correspond to the following: 

208 Volt Element  

14.1-16.4 

 

240 Volt Element  

18.8-21.8 

 

If the resistance is outside of the rating, the element needs to be changed. Also check for continuity to ground on 

each end of the suspect element. There should be no continuity to ground. 

Relay

 

Board

 

NOTE:  J connectors are marked on the relay board. 

With 24 VAC supplied to pin #2 at connector J35 and a good F1 fuse, the relay board has a 24 VAC output at pin 

#2 on connectors J33 and J34 and the AC indicator is illuminated. 

When the board receives a 24 VDC SO input at pin #7 on connector J31 or J33, the SO indicator is illuminated, 

the SO relay is energized, and there is a 24 VAC output at pin #4 on connector J32. 

Summary of Contents for Solstice SE Series

Page 1: ...L22 330 R1 10 12 Solstice Electric Fryers SE Series Service Manual...

Page 2: ...r equipment contact the Pitco Frialator Authorized Service and Parts representative ASAP covering your area or contact Pitco at the numbers listed above MAILING ADDRESS Pitco Frialator P O Box 501 Con...

Page 3: ...for Second Resistance 18 Checking the Resistance of the DVI Switch 18 Checking the Resistance of the Safety Contactor 19 Checking the Resistance of the HD Contactor 20 Checking the Resistance of the...

Page 4: ...Wiring Diagrams 56 Simplified Wiring Diagrams 57 US and Canada Wiring Diagrams Controls 58 US and Canada Wiring Diagrams Replacement Parts List 59 US and Canada Wiring Diagrams Basket Lift Option 60 U...

Page 5: ...Pitco Solstice Electric Fryers SE Series Service Manual 5 Serial Numbers...

Page 6: ...Pitco Solstice Electric Fryers SE Series Service Manual 6...

Page 7: ...Pitco Solstice Electric Fryers SE Series Service Manual 7 Theory of Operation...

Page 8: ...nterlock DVI input at the controller 24 VAC is at the Side On SO relay COM contact The controller is turned ON The SO indicator on the relay board is illuminated The SO relay is energized closing the...

Page 9: ...otor stops running and the return valve closes The pump system is equipped with a circuit breaker which de energizes the system and the heat tape in the event of over current The circuit breaker must...

Page 10: ...Pitco Solstice Electric Fryers SE Series Service Manual 10 SE Model...

Page 11: ...e Electric Fryers SE Series Service Manual 11 Accessing Fryer for Servicing Powering Down the Unit 1 Press the OFF button on control panel 2 Slide button to solid state 3 Unplug all power cord and dis...

Page 12: ...zel 1 Remove the two 2 screws on the controller panel using a Phillips screwdriver 2 Pull out the controller panel front bezel 3 Disconnect the controller wiring harness 4 Remove the controller panel...

Page 13: ...er located on the left side of the unit using a Philips screwdriver 2 Remove the four 4 screws entrance box lower cover located on the right side of the unit using a Philips screwdriver 3 Remove the t...

Page 14: ...Service Manual 14 Removing the Entrance Box Wire Guard 1 Remove the two 2 screws on the wire guard using a 5 16 inch hex wrench 2 Slide the wire guard down to remove 3 Follow steps 1 through 2 in reve...

Page 15: ...Removing the Controller Front Panel Bezel on page 12 2 Disconnect all the connections J41 J35 J32 and J34 from the relay board 3 Remove the four 4 screws which hold down the relay board bracket using...

Page 16: ...c Fryers SE Series Service Manual 16 Removing Solid State Thermostat If Necessary 1 Remove the two 2 screws which hold the solid state thermostat using a 5 16 inch socket 2 Disconnect solid state ther...

Page 17: ...Removing the Entrance Box Covers on page 13 and entrance box wire guard see Removing the Entrance Box Wire Guard on page 14 2 Disconnect the secondary side terminals 3 Connect the multimeter to the se...

Page 18: ...V 25 3 5 2 440V 107 7 5 3 120V 9 9 5 3 380V 90 2 PP10429 PP10428 Secondary Resistance Secondary Resistance Primary Resistance Primary Resistance Diagram Identifying Terminals for Second Resistance Che...

Page 19: ...panel see Removing the Controller Front Panel Bezel on page 12 entrance box covers see Removing the Entrance Box Covers on page 13 and entrance box wire guard see Removing the Entrance Box Wire Guard...

Page 20: ...oving the Controller Front Panel Bezel on page 12 entrance box covers see Removing the Entrance Box Covers on page 13 and entrance box wire guard see Removing the Entrance Box Wire Guard on page 14 2...

Page 21: ...tco Solstice Electric Fryers SE Series Service Manual 21 Checking the Resistance of the Hi Limit 1 Remove the Hi Limit connection 2 Connect the multimeter to the Hi limit leads and check the resistanc...

Page 22: ...tric Fryers SE Series Service Manual 22 Checking the Resistance of the Probe 1 Remove the probe connection 2 Connect the multimeter to the thermostat leads and check the resistance See Probe Resistanc...

Page 23: ...tor NOTE Make sure the insulator does not have puncture marks in it 5 Follow steps 1 through 2 to finish the replacement of relay board and paper Replacing the Transformer 1 Remove the front panel see...

Page 24: ...lectric Fryers SE Series Service Manual 24 4 Remove transformer box from the unit Transformer Wiring NOTE Wire according to the appropriate voltage 5 Follow steps 1 through 3 in reverse to install the...

Page 25: ...athead screwdriver 2 Loosen the two 2 screws which hold the actuator using a Philips screwdriver 3 Unfasten the switch harness from the wire channel 4 Remove the switch from mounting plate using a nar...

Page 26: ...Connections Table Safety Contactor Connections Wires L1 top 1B L2 top 2B L3 top 3B T1 bottom 1D T2 bottom 2D T3 bottom 3D 2 Loosen the top screw on the safety contactor using a Philips screwdriver 3 R...

Page 27: ...plate behind the HD contactor using a Philips screwdriver 3 Cut the zip tie under the HD contractor to access the bottom screw on the plate 4 Remove the bottom screw on the mounting plate using a Phi...

Page 28: ...the probe clamps but do not remove it Turn the rear probe clamp down and remove all three probe clamp pieces 4 Remove the probe nut with 7 16 inch socket 5 Cut the probe wires at the termination end c...

Page 29: ...wires black with black and white with white 10 Fasten the connectors to the wire channel NOTE Use the appropriate set of connections on the wire channel Full Split 11 Follow steps 1 through 4 in rever...

Page 30: ...ted to the entrance box wire channel 5 Pull the hi limit and wires through the tank fitting 6 Slide the wires of new hi limit through the tank fitting and install a new hi limit cartridge 7 Install th...

Page 31: ...g the left element of the SE14 tank remove the hi limit clamps see step 1 in Replacing the Hi Limit on page 30 2 Remove the five 5 element bolts using a 7 16 inch socket 3 Push down on the front of th...

Page 32: ...Pitco Solstice Electric Fryers SE Series Service Manual 32 6 Replace the element o rings if needed 7 Follow steps 1 through 5 in reverse to finish the replacement of the new element...

Page 33: ...and entrance box wire guards see Removing the Entrance Box Wire Guard on page 14 2 Remove the top deck using a 5 16 inch hex wrench 3 Remove the top deck heat shield using a 5 16 inch hex wrench 4 Lo...

Page 34: ...the drain extension nipples 9 Remove the four 4 screws that hold down the entrance box using a 5 16 inch socket 10 Disconnect the filter pump box power supply 11 Disconnect the following connectors at...

Page 35: ...net back cover using a 5 16 inch socket 17 Disconnect all return hoses from the tank being replaced using an adjustable wrench 18 Remove the cotter pin from filter return handle using needle nose plie...

Page 36: ...screwdriver or utility knife 23 Remove the elements in steps 1 through 5 in Replacing the Element on page 31 NOTE Retain all removed clamps 24 Remove tank from cabinet 25 Set tank on floor 26 Remove t...

Page 37: ...g screws on the wire channel using a Phillips screwdriver 31 Remove the entrance box and wire channel assembly as one piece 32 Remove the entrance box support brackets from entrance box heat shields u...

Page 38: ...Pitco Solstice Electric Fryers SE Series Service Manual 38 Filter System...

Page 39: ...3 way return valve in the back of the unit using a 15 16 inch wrench 2 Remove the male quick disconnect using a 15 16 inch wrench 3 Unplug the proximity switch 4 Remove two 2 screws holding the flush...

Page 40: ...e the two 2 screws from the valve mounting brackets using a 5 16 socket 8 Slide the bracket to the back of the assembly 9 Lift bracket out and slide forward 10 Bend down tabs of the stem nut washer us...

Page 41: ...Manual 41 12 Remove the handle 13 Remove the mounting bracket 14 Remove the piping using a 15 16 inch wrench on the valve and an adjustable wrench on the piping 15 Replace the flush hose assembly and...

Page 42: ...Loosen the pump inlet tube using a crescent wrench 2 Unscrew and remove the inlet valve of the filter pump system 3 Pull out pump inlet tube 4 Remove filter pan cover not shown 5 Disconnect the connec...

Page 43: ...loor once the pins are pulled out It is recommended that you brace the pump and motor before pulling out the pins 9 Turn down the pins and then pull them out 10 Lower the filter pump to the floor and...

Page 44: ...stable wrenches 14 Reinstall a new filter pump by following steps 1 through 13 in reverse Replacing Seal Kit 1 Remove the four 4 bolts on filter pump using 7 16 inch open ended wrench 2 Remove the fil...

Page 45: ...the Filter Pump from the Motor 1 Remove the two 2 bolts holding the filter pump head to the motor using a 1 2 inch open ended wrench 2 Remove the filter pump head from the motor 3 Reinstall the filte...

Page 46: ...connect the connections and power supply cords from the filter pump 2 Remove the pump box 3 Remove the circuit breaker from the pump box 4 Remove all wires on the circuit breaker using needle nose pli...

Page 47: ...Relay 1 Remove the two 2 screws which hold the pump relay using a Phillips screwdriver 2 Remove all wires on the pump relay using needle nose pliers See Wiring Schematics on page 57 3 Remove the pump...

Page 48: ...Pitco Solstice Electric Fryers SE Series Service Manual 48 Troubleshooting and Problem Isolation...

Page 49: ...Pitco Solstice Electric Fryers SE Series Service Manual 49 Troubleshooting and Problem Isolation Interpretation of Solid State Controller Lights...

Page 50: ...to stabilize 2 Measure the vat center oil temperature and compare this with the knob pointer scale 3 To reposition the knob pry off the cap of the knob with a sharp knife blade 4 Without turning the...

Page 51: ...the oil to cool and check the probe resistance at a lower temperature Looking at the probe resistance chart a greater resistance variation is tolerated at a lower temperature HD Contactor The HD cont...

Page 52: ...using the relay to de energize and the pump to stop pumping These switches can be checked with a meter When the switch is closed there should be continuity The normal gap between the actuator and the...

Page 53: ...a short If display reads DRAINING TURN OFF verify that the drain valve is closed check the proximity switch on the drain valve turn the fryer off and then turn the fryer on Backup Solid State Control...

Page 54: ...indicates an open or shorted probe or wires in between the probe and the controller If none of the indicators illuminate when the controller is turned on verify that the drain valve is closed and tha...

Page 55: ...723 410 210 0 494 24 85 29 4 75136 250 121 1 3458 415 212 8 470 16 90 32 2 66823 255 123 9 3214 420 215 6 447 49 95 35 0 59540 260 126 7 2991 425 218 3 426 13 100 37 8 53146 265 129 4 2785 430 221 1 4...

Page 56: ...Pitco Solstice Electric Fryers SE Series Service Manual 56 Wiring Diagrams...

Page 57: ...Pitco Solstice Electric Fryers SE Series Service Manual 57 Simplified Wiring Diagrams...

Page 58: ...Pitco Solstice Electric Fryers SE Series Service Manual 58 US and Canada Wiring Diagrams Controls...

Page 59: ...Pitco Solstice Electric Fryers SE Series Service Manual 59 US and Canada Wiring Diagrams Replacement Parts List...

Page 60: ...Pitco Solstice Electric Fryers SE Series Service Manual 60 US and Canada Wiring Diagrams Basket Lift Option...

Page 61: ...Pitco Solstice Electric Fryers SE Series Service Manual 61 US and Canada Wiring Diagrams Filter Pump Option...

Page 62: ...Pitco Solstice Electric Fryers SE Series Service Manual 62 US and Canada Wiring Diagrams Single Phase Twin Vat...

Page 63: ...Pitco Solstice Electric Fryers SE Series Service Manual 63 US and Canada Wiring Diagrams Single Phase Full Vat...

Page 64: ...Pitco Solstice Electric Fryers SE Series Service Manual 64 US and Canada Wiring Diagrams 3 Phase Full Vat...

Page 65: ...Pitco Solstice Electric Fryers SE Series Service Manual 65 Export and CE Wiring Diagrams Filter Pump Option...

Page 66: ...Pitco Solstice Electric Fryers SE Series Service Manual 66 Export and CE Wiring Diagrams Single Phase Twin Vat...

Page 67: ...Pitco Solstice Electric Fryers SE Series Service Manual 67 Export and CE Wiring Diagrams Single Phase Full Vat...

Page 68: ...Pitco Solstice Electric Fryers SE Series Service Manual 68 Export and CE Wiring Diagrams 3 Phase Full Vat...

Page 69: ...Pitco Solstice Electric Fryers SE Series Service Manual 69 Export and CE Wiring Diagrams 3 Phase Twin WYE Vat...

Page 70: ...Pitco Solstice Electric Fryers SE Series Service Manual 70 Export and CE Wiring Diagrams 3 Phase Twin Delta Vat...

Page 71: ...Pitco Solstice Electric Fryers SE Series Service Manual 71 Notes...

Page 72: ...ctory at 603 225 6684 World Wide www pitco com In the event of problems with questions about your order please contact Pitco Frialator Authorized Service and Parts representative ASAP covering your ar...

Reviews: