Replacing
the
Probe
1.
Remove the basket hanger.
2.
Remove one (1) of the screws from probe
clamps using a Phillips screwdriver.
3.
Loosen the other screw on the probe clamps, but
do not remove it. Turn the rear probe clamp
down and remove all three probe clamp pieces.
4.
Remove the probe nut with 7/16 inch socket.
5.
Cut the probe wires at the termination end
connected to the entrance box wire channel.
6.
Pull the probe and wires through the tank fitting.
7.
Slide the probe wires through the probe nut and
ferrule, and then slide the probe nut and ferrule
through the probe.