background image

   L20-246 Rev 0 (12/01)

WARNING

At operating temperature, the shortening in
the fryer may be hotter than 375°F (190°C).
This hot, melted shortening will cause severe
burns.  Do not let the hot shortening touch
your skin or clothing.  Always wear insu-
lated oil-proof gloves when working on the
filter system.  It will be easier and safer if
the filter assembly has cooled to room tem-
perature before handling any filter parts.

a.

With the filter pan empty of oil,  remove the
filter media by grasping the filter pan handle
and gently pull the assembly toward the front
of the fryer.

b.

Separate the filter pickup tube from the filter
pickup screen assembly by pulling up on the
pickup tube just above where it connects to
the pickup screen assembly.  Lift pickup tube
and swing it to the left, until it rests on the left
hand side of the filter pan.

c.

Grab filter screen pickup assembly lift
handles and carry it to a trash barrel and
shake off heavy discard any debris that may
be built upon the top of the assembly.

d.

Unscrew the filter paper clip bracket  from
the filter paper support screen and slide the
filter paper support screen out of the filter
paper clip bracket.

e.

Remove filter paper support screen from the
filter envelope.

f.

All of the filter pick up assembly parts can be
washed in a dish washer or a pot sink.  Flush
out the suction tube assembly with hot water.
After cleaning, it is very important to thor-
oughly dry the parts before reassembling.
Water and oil do not mix.  Water in hot oil
will cause the oil to splatter.

g.

Start reassembling the filter pick up assembly
by sliding the  new filter paper on to the filter
paper support rack.  Ensure that the hole in
the filter paper goes over the pick up tube
assembly threaded connector.

h.

Fold the open end of the bag in two folds.
The first fold should be approximately 1
inch from the end and the second should be
over the edge of the rack assembly.

i.

Slide the clip screen over the folded end of
the filter paper.  Ensure the opening of the
clip screen goes over the pick up tube
connection.  Screw the suction tube con-
nection onto the threaded connection.

j.

Place the filter pickup assembly into the
filter pan and slide the filter pan assembly
back into the fryer cabinet.

k.

Filter unit is now ready for use.

ENGLISH

Summary of Contents for SE Series

Page 1: ...ion Manual For Electric Fryers Covering Models SE SEH Series Pitco Frialator Inc P O Box 501 Jct I 89 I 93 Concord NH 03302 0501 509 Route 3A Bow NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 L20 246 Rev 0 01 03 ENGLISH ...

Page 2: ...ERVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THIS APPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY AND AS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BY A QUALIFIED TECHNI CIAN ON A YEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECT...

Page 3: ...terial or workmanship for a period of two years B If the computer is found to be defective dur ing the first 2 years after the installation date Pitco Frialator Inc will also pay for the la bor freight and travel costs involved in re placing said part 4 WARRANTYPROVISIONS ELEMENTS A Pitco Frialator Inc will warrant the Electric Elements from defects in material or work manship for a period of 3 ye...

Page 4: ... performed by qualified personnel The duct system the hood system and the fryers must be cleaned on a regular basis and must be kept clear of any grease build up Ventilation A proper ventilation system is also an impor tant part of the installation Clearances Minimum clearance of 6 15cm must be maintained from combustible construction on each side and the rear of the equipment This equipment may b...

Page 5: ...left key for the left side of a split vat computer to turn the unit ON The computer display will light and the heating elements will begin to heat and will be controlled by the computer controller NOTE It is recommended that melt cycle be used This will extend the shortening life In melt cycle the shortening turns from solid to liquid gradually through short controlled bursts of heat Once the pred...

Page 6: ...d handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank f When bubbles are seen coming out of the oil return spout close the red handled valve to turn the pump off If necessary add more oil to the tank to return the oil level to the fill mark The fryer is now ready for use DRAINING A TANK The filter system is also used to drain...

Page 7: ...chine is now ready to use ENGLISH 4 PlacethePaperSupportScreeninthebottomofthe pan Place filter Paper or Pad over screen making sure that there is an equal amount of excess paper on each side Place the Retaining Frame on the paper or pad making sure that all edges are being pressed down evenly Slide filter drawer back under fryer making sure that the oil return pipe locates into its mating connect...

Page 8: ...rain Use the brush to clean the sides of the tank as the oil drains WARNING This filter pan is only large enough to hold the contents of one 1 tank at once during the filter process g When the tank is empty close the green handled drain valve Open the red handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank h When bubbles are ...

Page 9: ...p bracket from the filter paper support screen and slide the filter paper support screen out of the filter paper clip bracket e Remove filter paper support screen from the filter envelope f All of the filter pick up assembly parts can be washed in a dish washer or a pot sink Flush out the suction tube assembly with hot water After cleaning it is very important to thor oughly dry the parts before r...

Page 10: ...ture is entered boil mode will start automatically You must turn off both fryers to exit Boil mode After 5 secs machine will return to run mode After 5 secs machine will return to run mode CHECKING THE REMAINING TIME WHEN USING MULTIPLE TIMERS TO VIEW REMAINING TIME ON ANY FUNCTION KEYS WHEN MULTIPLE TIMERS ARE COUNTING IS AS FOLLOWS PRESS THEN PRESS FUNCTION KEY OF ANY NON DISPLAYED ACTIVE TIMERS...

Page 11: ...L20 246 Rev 0 12 01 ENGLISH 6 ...

Page 12: ...L20 246 Rev 0 12 02 7 ...

Page 13: ...L20 246 Rev 0 12 01 ENGLISH 8 ...

Page 14: ...r behind the door of left hand fryer D Sensor switch may be loose D If the mounting screws are loose try to tighten them if this is not possible call an Authorized Service Agency Drain valve is closed and A GREEN drain valve is not A Apply a little more pressure to close the valve the computer has been fully closed reset but still shows B Sensor switch may be loose B If the mounting screws are loo...

Page 15: ...L20 246 Rev 0 12 01 10 ENGLISH ...

Page 16: ...he Pitco Frialator Authorized Service and Parts representative ASAP covering you area or contact Pitco at the numbers listed to the left In the event of problems with or questions about your order please contact the Pitco Frialator fac tory at 800 258 3708 US and Canada only or 603 225 6684 World Wide ...

Reviews: