background image

L20-246 Rev 0 (12/02)

         

 3

FILTER PROCEDURES FOR
FLAT PAPER FILTER SYSTEMS

NOTE

When working with hot oil ALWAYS wear oil

proof, insulated gloves.

WARNING

NEVER - Run the filter system without a filter

bag/paper.

NEVER - Empty the oil from the fryer before

turning OFF the fryer burners.

NEVER - Store the  Filter Unit anywhere other

than in the fryer filter cavity.

a.

Slide the  filter pan out.  Carefully remove
filtered residue off the filter media.  Examine
the filter media for clogged or torn areas.
Refer to filter media replacement instructions
following this section.  Reinstall the pan.

b.

Turn the fryer that is to be filtered OFF (See
Standby Shutdown).  Remove the baskets
from the fryer tank(s).  Use the clean out
brush to lift out the tube screens.

c.

Check the pickup tube screen by unscrewing
the cap counterclockwise. Any debris should
be cleaned from the screen before using the
filter system. Reinstall the screen by scewing
the cap back on clockwise. Do not over-
tighten.

c.

Slowly open the green handled drain valve
for the tank being filtered.  If necessary use
the clean-brush  to clear the crumbs from the
drain.  Use the brush to clean the sides of the
tank as the oil drains.

WARNING

This filter pan is only large enough to hold the

contents of one (1) tank at once, during the

filter process.

e.

When the tank is empty, close the green
handled drain valve.  Open the red handled

return valve to the tank you are filtering.
This will start the pump and return the oil to
the bottom of the fry tank.

f.

When bubbles are seen coming out of the oil
return spout, close the red handled valve to
turn the pump off.
If necessary add more oil to the tank to return
the oil level to the fill mark.  The fryer is
now ready for use.

DRAINING A TANK

The filter system is also used to drain the fryers.  You
will need a container capable of holding 400

0

F oil and

protective gloves.

a.

Rotate the drain down spout so that it ex-
tends in the container that you want to drain
the shortening into.

b.

Open the green handled drain valve for the
tank to be drained.  The oil will drain into the
container you have chosen.  When the con-
tainer is full or the fry tank is empty, close
the green handled drain valve.  If the con-
tainer was full repeat this step until fryer tank
is empty.

c.

Once tank is completely empty add new
shortenning and follow fryer start up proce-
dures.

WARNING

The power supply must be disconnected before

servicing or cleaning the appliance.

Preparing the filter for use:

·

Slide drawer forward until it stops.

·

Grasp the Left and Right handles of the Paper
Retaining Frame and lift upward to remove it.

·

Remove the filter paper or pad by folding the edges
inward so that the debris is collected.

·

Lift the Paper Support Screen out of the pan.

·

The Pan, Paper Support Screen and Paper Retain-
ing Frame can now be cleaned.

NOTE:

 Be sure that the filter pan is free of any debris

which could cause the paper and hold down ring not
to seat properly.

Summary of Contents for SE Series

Page 1: ...ion Manual For Electric Fryers Covering Models SE SEH Series Pitco Frialator Inc P O Box 501 Jct I 89 I 93 Concord NH 03302 0501 509 Route 3A Bow NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 L20 246 Rev 0 01 03 ENGLISH ...

Page 2: ...ERVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THIS APPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY AND AS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BY A QUALIFIED TECHNI CIAN ON A YEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECT...

Page 3: ...terial or workmanship for a period of two years B If the computer is found to be defective dur ing the first 2 years after the installation date Pitco Frialator Inc will also pay for the la bor freight and travel costs involved in re placing said part 4 WARRANTYPROVISIONS ELEMENTS A Pitco Frialator Inc will warrant the Electric Elements from defects in material or work manship for a period of 3 ye...

Page 4: ... performed by qualified personnel The duct system the hood system and the fryers must be cleaned on a regular basis and must be kept clear of any grease build up Ventilation A proper ventilation system is also an impor tant part of the installation Clearances Minimum clearance of 6 15cm must be maintained from combustible construction on each side and the rear of the equipment This equipment may b...

Page 5: ...left key for the left side of a split vat computer to turn the unit ON The computer display will light and the heating elements will begin to heat and will be controlled by the computer controller NOTE It is recommended that melt cycle be used This will extend the shortening life In melt cycle the shortening turns from solid to liquid gradually through short controlled bursts of heat Once the pred...

Page 6: ...d handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank f When bubbles are seen coming out of the oil return spout close the red handled valve to turn the pump off If necessary add more oil to the tank to return the oil level to the fill mark The fryer is now ready for use DRAINING A TANK The filter system is also used to drain...

Page 7: ...chine is now ready to use ENGLISH 4 PlacethePaperSupportScreeninthebottomofthe pan Place filter Paper or Pad over screen making sure that there is an equal amount of excess paper on each side Place the Retaining Frame on the paper or pad making sure that all edges are being pressed down evenly Slide filter drawer back under fryer making sure that the oil return pipe locates into its mating connect...

Page 8: ...rain Use the brush to clean the sides of the tank as the oil drains WARNING This filter pan is only large enough to hold the contents of one 1 tank at once during the filter process g When the tank is empty close the green handled drain valve Open the red handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank h When bubbles are ...

Page 9: ...p bracket from the filter paper support screen and slide the filter paper support screen out of the filter paper clip bracket e Remove filter paper support screen from the filter envelope f All of the filter pick up assembly parts can be washed in a dish washer or a pot sink Flush out the suction tube assembly with hot water After cleaning it is very important to thor oughly dry the parts before r...

Page 10: ...ture is entered boil mode will start automatically You must turn off both fryers to exit Boil mode After 5 secs machine will return to run mode After 5 secs machine will return to run mode CHECKING THE REMAINING TIME WHEN USING MULTIPLE TIMERS TO VIEW REMAINING TIME ON ANY FUNCTION KEYS WHEN MULTIPLE TIMERS ARE COUNTING IS AS FOLLOWS PRESS THEN PRESS FUNCTION KEY OF ANY NON DISPLAYED ACTIVE TIMERS...

Page 11: ...L20 246 Rev 0 12 01 ENGLISH 6 ...

Page 12: ...L20 246 Rev 0 12 02 7 ...

Page 13: ...L20 246 Rev 0 12 01 ENGLISH 8 ...

Page 14: ...r behind the door of left hand fryer D Sensor switch may be loose D If the mounting screws are loose try to tighten them if this is not possible call an Authorized Service Agency Drain valve is closed and A GREEN drain valve is not A Apply a little more pressure to close the valve the computer has been fully closed reset but still shows B Sensor switch may be loose B If the mounting screws are loo...

Page 15: ...L20 246 Rev 0 12 01 10 ENGLISH ...

Page 16: ...he Pitco Frialator Authorized Service and Parts representative ASAP covering you area or contact Pitco at the numbers listed to the left In the event of problems with or questions about your order please contact the Pitco Frialator fac tory at 800 258 3708 US and Canada only or 603 225 6684 World Wide ...

Reviews: