CAUTION:

This equipment is manufactured for the use on a
particular voltage and phase which is specified on
the rating plate located on the inside of the door.

When your fryers arrive, inspect carefully

noting any damage on the freight bill. If concealed
damage is found after you have accepted the
equipment, report it to the carrier immediately as
all claims must be filled within 15 days of the
receipt of the shipment. Also, be sure to keep all
packing materials as these will be necessary to
make any claim.

Follow these installation instructions care-

fully. A proper installation is important for the
operation of the fryers.

All installations must conform to all local and

national codes.

Do not block the area around the casters and

under the fryers. Contact the Authorized Pitco
Frialator representative for any service related
problems. Routine maintenance may be performed
by qualified personnel.

The duct system, the hood system and the

fryers must be cleaned on a regular basis and must
be kept clear of any grease build up.

Ventilation:

A proper ventilation system is also an impor-

tant part of the installation.

Clearances:

Minimum clearance of 6" (15cm) must be

maintained from combustible construction on each
side and the rear of the equipment. This equipment
may be installed on combustible floors.

Maintain a minimum of 24"(61cm) clearance

in front of the fryer to provide for proper opera-

tion, maintenance and servicing.

Wiring diagram(s) are located in the back of

the service manual and inside the fryers.

Regular cleaning of this equipment, as well as

the hood, is an important part of proper mainte-
nance.

Once the fryers are in place:

Leveling the fryers will help ensure proper

operation. To level the fryers loosen the two set
screws on the caster stem. Rotate the collar of the
caster to raise or lower the height of the unit.
Tighten set screws to lock the adjustment. Casters
should be adjusted so that the fryers are level and
at the correct height under the hood system.

                                                                          

 1

Summary of Contents for SE Series

Page 1: ...ion Manual For Electric Fryers Covering Models SE SEH Series Pitco Frialator Inc P O Box 501 Jct I 89 I 93 Concord NH 03302 0501 509 Route 3A Bow NH 03304 800 258 3708 603 225 6684 FAX 603 225 8497 L20 246 Rev 0 01 03 ENGLISH ...

Page 2: ...ERVICE TECHNICIAN THE MODEL SERIAL NUMBER AND ELECTRICAL REQUIREMENTS STAMPED INTO THE DATA PLATE LOCATED ON THE INSIDE PANEL OF THE DOOR NOTICE THIS APPLIANCE IS INTENDED FOR PROFESSIONAL USE ONLY AND AS SUCH SHOULD BE OPERATED BY FULLY TRAINED PERSONNEL NOTICE IT IS RECOMMENDED THAT THIS MACHINE BE INSPECTED BY A QUALIFIED TECHNI CIAN ON A YEARLY BASIS WARNING THE POWER SUPPLY MUST BE DISCONNECT...

Page 3: ...terial or workmanship for a period of two years B If the computer is found to be defective dur ing the first 2 years after the installation date Pitco Frialator Inc will also pay for the la bor freight and travel costs involved in re placing said part 4 WARRANTYPROVISIONS ELEMENTS A Pitco Frialator Inc will warrant the Electric Elements from defects in material or work manship for a period of 3 ye...

Page 4: ... performed by qualified personnel The duct system the hood system and the fryers must be cleaned on a regular basis and must be kept clear of any grease build up Ventilation A proper ventilation system is also an impor tant part of the installation Clearances Minimum clearance of 6 15cm must be maintained from combustible construction on each side and the rear of the equipment This equipment may b...

Page 5: ...left key for the left side of a split vat computer to turn the unit ON The computer display will light and the heating elements will begin to heat and will be controlled by the computer controller NOTE It is recommended that melt cycle be used This will extend the shortening life In melt cycle the shortening turns from solid to liquid gradually through short controlled bursts of heat Once the pred...

Page 6: ...d handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank f When bubbles are seen coming out of the oil return spout close the red handled valve to turn the pump off If necessary add more oil to the tank to return the oil level to the fill mark The fryer is now ready for use DRAINING A TANK The filter system is also used to drain...

Page 7: ...chine is now ready to use ENGLISH 4 PlacethePaperSupportScreeninthebottomofthe pan Place filter Paper or Pad over screen making sure that there is an equal amount of excess paper on each side Place the Retaining Frame on the paper or pad making sure that all edges are being pressed down evenly Slide filter drawer back under fryer making sure that the oil return pipe locates into its mating connect...

Page 8: ...rain Use the brush to clean the sides of the tank as the oil drains WARNING This filter pan is only large enough to hold the contents of one 1 tank at once during the filter process g When the tank is empty close the green handled drain valve Open the red handled return valve to the tank you are filtering This will start the pump and return the oil to the bottom of the fry tank h When bubbles are ...

Page 9: ...p bracket from the filter paper support screen and slide the filter paper support screen out of the filter paper clip bracket e Remove filter paper support screen from the filter envelope f All of the filter pick up assembly parts can be washed in a dish washer or a pot sink Flush out the suction tube assembly with hot water After cleaning it is very important to thor oughly dry the parts before r...

Page 10: ...ture is entered boil mode will start automatically You must turn off both fryers to exit Boil mode After 5 secs machine will return to run mode After 5 secs machine will return to run mode CHECKING THE REMAINING TIME WHEN USING MULTIPLE TIMERS TO VIEW REMAINING TIME ON ANY FUNCTION KEYS WHEN MULTIPLE TIMERS ARE COUNTING IS AS FOLLOWS PRESS THEN PRESS FUNCTION KEY OF ANY NON DISPLAYED ACTIVE TIMERS...

Page 11: ...L20 246 Rev 0 12 01 ENGLISH 6 ...

Page 12: ...L20 246 Rev 0 12 02 7 ...

Page 13: ...L20 246 Rev 0 12 01 ENGLISH 8 ...

Page 14: ...r behind the door of left hand fryer D Sensor switch may be loose D If the mounting screws are loose try to tighten them if this is not possible call an Authorized Service Agency Drain valve is closed and A GREEN drain valve is not A Apply a little more pressure to close the valve the computer has been fully closed reset but still shows B Sensor switch may be loose B If the mounting screws are loo...

Page 15: ...L20 246 Rev 0 12 01 10 ENGLISH ...

Page 16: ...he Pitco Frialator Authorized Service and Parts representative ASAP covering you area or contact Pitco at the numbers listed to the left In the event of problems with or questions about your order please contact the Pitco Frialator fac tory at 800 258 3708 US and Canada only or 603 225 6684 World Wide ...

Reviews: