5
Filter System:
Opening the RED Return Valve Handle will cause
the Pump On Relay to be energized and the pump
will begin to pump. Closing the Return Valve Handle
will de - energize the Relay and the Pump will stop
pumping.
Hood Relay System:
There is one Hood Relay (K15) per "battery" of fry-
ers, it is wired in parallel to every computer (both
sides of a split vat). When any side of any computer
is turned ON this Relay (K15) will energize and will
stay energized until all of the computers are turned
OFF.
Chapter 2: COMPONENT
TROUBLESHOOTING:
Probe:
The resistance of the probe will change as the tem-
perature changes. The resistance will decrease as the
temperature rises. The lower the temperature the
greater the resistance change will be per degree of
temperature change, as the temperature approaches
the working range of the probe, the resistance change
will become more linear.
If the probe is suspect, check its resistance and the
oil/air temperature at which it was taken. Compare
these values on the chart below.
TEMP
RESISTANCE
TEMP
RESISTANCE
°F
Ohms
°F
Ohms
60
139055
330
1192
80
84644
335
1123
100
53146
340
1058
120
34328
345
998
140
22755
350
942
160
15446
355
890
180
10716
360
841
200
7586
365
795
210
6427
370
752
220
5470
375
712
240
4013
380
675
260
2991
385
640
280
2262
390
607
300
1734
395
576
320
1347
400
547
325
1267
If the probe returns an open circuit or O Ohms read-
ing it should be replaced. If the resistance varies more
than 20 Ohms when being checked between 325-
375°F the probe will give a false temperature read-
ing on the computer and should be replaced. How-
ever, it will continue to operate at a slightly higher
or lower temperature. Allow the oil to cool and check
the probe resistance at a lower temperature. As can
be seen from the chart a greater degree of offset can
be allowed at a lower temperature.
Summary of Contents for ME14S-C/MFD
Page 16: ......
Page 17: ...PARTS SECTION...
Page 19: ......
Page 21: ......
Page 23: ......
Page 25: ......
Page 27: ......
Page 29: ......
Page 31: ......
Page 33: ......
Page 34: ...ME14 SCHEMATIC 700246H...
Page 35: ...ME14 DOMESTIC FULL SPLIT VAT CONTROL SCHEMATIC 700246H...
Page 36: ...ME14 DOMESTIC FULL SPLIT VAT HI POWER SCHEMATIC 700246H...
Page 37: ......