High Temperature Limit Upgrade Instructions Model CPE14
with Digital Controller
L80-038 Rev. 1
Page 5 of 5
11/6/2012
A) High Temperature Limit
Subassembly
B) Self
Tapping
Screws
Diagram G
Connector Connection
CB1 Circuit
Breaker
J3 Temperature
Probe
J5
High Temperature Limit
J6 DVI
Jumper
P1 Controller
P4 Other
Connection
Diagram H
8. Fill the cook tank with water and inspect the tank coupling
connections to assure that they are leak free.
9. Drain the water from the tank before proceeding.
10. Attach the high temperature limit subassembly to the front entrance
box using two 10-24 self tapping screws. (See Diagram G)
11. Connect the DVI jumper to the connector with orange and violet/white
wires on the
new
front entrance box wiring. (See Diagram H)
12. Connect the
new
front entrance box wiring to the components in the
front entrance box as shown. (See Diagram H)
13. Connect the new front entrance box wiring to the controller located
on the bezel.
14. Reinstall the bezel and secure using the
two screws removed during disassembly.
15. Replace the schematic label located
inside the door with the
new
schematic
label.
16. Startup the appliance per the procedure
shown in its installation and operation
manual. Assure that the appliance is
operating properly.
Schematic
Location
Description
A
Entrance Box, Rear
B
Entrance Box, Front
C Front
Panel
Component
Description
A1 Controller
CB1 Circuit
Breaker
HL1
High Temperature Limit
HR1 Heating
Element
K1, K2
Contactor
LS1 DVI
MP1 Ground
RT1 Temperature
Probe
T1 Transformer
TB1, TB2 Terminal Block
Schematic Key