High Temperature Limit Upgrade Instructions Model CPE14
with Digital Controller
L80-038 Rev. 1
Page 3 of 5
11/6/2012
A) High Temperature Limit Holes
Diagram C
Diagram D
Front Entrance Box Modification
1. Inspect the front entrance box to see if it has the hole pattern required to install the new high temperature
limit. Proceed to the following steps only if the front entrance box does
NOT include the hole pattern shown. (See Diagram C)
2.
Drill two 7/32” holes and one 5/16” hole in the front entrance box in the
outlined locations. (See Diagram D)
Diagram D is shown actual size
and therefore can be used as a template for locating hole centers.
3. Remove all burrs and sharp edges from the drilled holes. Remove any
metal shavings created from the drilling operation.