Pitco CPE14 Series High Temperature Limit Upgrade Instructions Download Page 3

High Temperature Limit Upgrade Instructions Model CPE14 

with Digital Controller

 

L80-038 Rev. 1 

Page 3 of 5 

11/6/2012 

 

A) High Temperature Limit Holes 

Diagram C 

Diagram D 

Front Entrance Box Modification 

 
1.  Inspect the front entrance box to see if it has the hole pattern required to install the new high temperature 

limit.  Proceed to the following steps only if the front entrance box does 
NOT include the hole pattern shown.  (See Diagram C) 

 

2. 

Drill two 7/32” holes and one 5/16” hole in the front entrance box in the 
outlined locations. (See Diagram D)  

Diagram D is shown actual size 

and therefore can be used as a template for locating hole centers. 

 
3.  Remove all burrs and sharp edges from the drilled holes.  Remove any 

metal shavings created from the drilling operation. 