High Temperature Limit Upgrade Instructions Model CPE14
with Digital Controller
L80-038 Rev. 1
Page 2 of 5
11/6/2012
A) Bezel Screws
B) Bezel
C) Controller
Diagram A
A) High Temperature Limit
B) Temperature
Probe
C) Circuit
Breaker
Diagram B
Tools Required
Flat blade screwdriver
Phillips screwdriver
11/16” Combination wrench
9/16” Combination wrench
3/8” Combination wrench
5/16” Socket and a ratchet
5/16” Combination wrench
Drill with 7/32” & 5/16” drill bits*
*may not be required for all upgrades
High Temperature Limit Removal
1. Ensure that the power is disconnected and that the
tank is drained.
2. Remove the two screws securing the bezel to the front
of the appliance. Keep the two screws in a safe place
since they will be required later. (See Diagram A)
3. Tilt the bezel down and disconnect the wire plug
connected to the controller. (See Diagram A)
4. Remove the Bezel from the appliance. Keep the bezel
in a safe place for reinstallation later.
5. Disconnect the wire harness from the high
temperature limit, temperature probe and circuit breaker. (See Diagram B)
6. Disconnect the remaining connection on the wire harness and remove the harness from the appliance.
7. Remove the high temperature limit from the appliance. (See Diagram B)
WARNING
The power supply must be disconnected
before servicing this appliance
.
WARNING
Drain the appliance before performing
the following procedure
.