Pitco CPE14 Series High Temperature Limit Upgrade Instructions Download Page 2

High Temperature Limit Upgrade Instructions Model CPE14 

with Digital Controller

 

L80-038 Rev. 1 

Page 2 of 5 

11/6/2012 

 

A) Bezel Screws 

B) Bezel 

C) Controller 

Diagram A 

 

A)  High Temperature Limit 
B) Temperature 

Probe 

 

C) Circuit 

Breaker 

Diagram B

Tools Required 

 

 

Flat blade screwdriver 

 

Phillips screwdriver 

 

11/16” Combination wrench 

 

9/16” Combination wrench 

 

3/8” Combination wrench 

 

5/16” Socket and a ratchet 

 

5/16” Combination wrench 

 

Drill with 7/32” & 5/16” drill bits* 

*may not be required for all upgrades

 
 
 
 
 
 

High Temperature Limit Removal 

 
1.  Ensure that the power is disconnected and that the 

tank is drained. 

 
2.  Remove the two screws securing the bezel to the front 

of the appliance.  Keep the two screws in a safe place 
since they will be required later.  (See Diagram A) 

 
3.  Tilt the bezel down and disconnect the wire plug 

connected to the controller.   (See Diagram A) 

 
4.  Remove the Bezel from the appliance.  Keep the bezel 

in a safe place for reinstallation later. 

 
5.  Disconnect the wire harness from the high 

temperature limit, temperature probe and circuit breaker.  (See Diagram B) 

 
6.  Disconnect the remaining connection on the wire harness and remove the harness from the appliance. 
 
7.  Remove the high temperature limit from the appliance.  (See Diagram B) 
 

 

WARNING 

The power supply must be disconnected 
before servicing this appliance

WARNING 

Drain the appliance before performing 
the following procedure

Reviews: