VII. Add more detectors
You can add new sensors or detectors, such as wireless door sensors,
PIR Sensors, gas and smoke detectors into the unit.
1) Add sensors ready to work when you set both
Out Arm
and
Home
Arm
:
When the GSM host begins to be powered on, the status LED light on
panel will be red for 20 seconds, this is code learning mode. You can
trigger the sensors or detectors, and the red LED will flash to show it is
coded successfully into the host.
The coding mode ends 20 seconds later automatically, and system
enters into working mode, status LED light on panel will change to
yellow, then to green.
2) Add sensors into inner defense zone. (Detectors in this zone are
ready to work when you set
Out Arm
, and will not work when you set
Home Arm
When the GSM host begins to be powered on, the status LED light on
panel will be red. Push the reset button for one second, the status LED
light will light up in orange for 20 seconds. This is code learning mode
of inner defense zone. You can trigger the sensors or detectors, the
LED will flash in red to show it is coded successfully into inner defense
zone.
For above operation, the host will exit code learning mode 20
seconds later automatically, and enters into working mode, the light on