87#--#
Wired zone Message(0-24bit)
90##
Show Output status in the host
91#1#
Set Output 1 to high
91#0#
Set Output 1 change to low
92#1#
Set Output 2 to high
92#0#
Set Output 2 change to low
93#1#
Set talk to the host
available (Output 3)
93#0#
Set
talk
to
the
host
unavailable (Output 3)
94#1#
Set
Relay
to
be
connected
94#0#
Set Relay to be disconnected
95#1#
Set alarm when input 1
open
95#0#
Set alarm when input 1
connect to GND*
96#1#
Set alarm when line
input 2 open
96#0#
Set alarm when line input 2
connect to GND*
97#1#
Set alarm when line
input 3 open
97#0#
Set alarm when line input 3
connect to GND*
Note
:
1. In the above table, ‘*’ stands for
default setting
.
2.
Alarm delay is not workable for smoke detector, gas detector or
emergency button. That is, even though this system is set as alarm
delay, triggering of the mentioned sensors will cause immediate
alarm without delay.
3.
In alarm delay state, if any of the door sensor, PIR sensor or wired
sensor is triggered, the siren will ring once per 5-second. After the
delay time, the siren will keep ringing consecutively, and the panel
will send SMS and make alarm call.
4. For the above phone operation, one beep shows your input