Password followed by Chime key to change system to Chime status
Use key chain to disarm system directly without entering any password
Other features
Set Door Open Time
During system disarm status, you can press default password
1 2 3 4 5 6
followed by Enter key. You will see Set indicator light on and Enter
key flashing and press
5 0
+
T T
(“T T” for time, from 01 to 99 seconds)
and
Enter
. This time is for how long you need an access to door
without triggering the alarm. For example, when you use a key chain or password to open the door, how long you would want the door to
be closed and system still be in arm status.
Wireless Encryption
If you had a neighbor having the same system or other devices that interfere your system and always results in false alarm, then during
system disarm status, press default password
1 2 3 4 5 6
followed by Enter key. When you see Set indicator light on and Enter key flashing,
press
4 0
+
dddd
(any 4 digits pass code --- you do not need to remember this pass code it is only for encrypting the system with other
device)
Change Password
After setting up your keypad, you may change the default password to your own password for safety.
During system disarm status, you can press default password
1 2 3 4 5 6
followed by Enter key. You will see Set indicator light on and Enter
key flashing. Then press
3 0 + new pa Enter,
repeat the
new password
follow by
Enter
one more time
(you may set new password
up to 6 digits). Then press Chime key to exit setting status. (Please keep your new password to a safe place and do not forget it)
Reset Password
If you forget your password, remove the keypad from the wall. At backside of the keypad, you will see
Reset
button, press the reset button
and hold for 3 seconds, it will reset the keypad password to default password
1 2 3 4 5 6
.
Wired Port Connection for Magnetic force lock or Electronics lock
(Option)
Magnetic force lock and Electronic lock. Please make sure which type of lock you have, and select the correct connection
Fig 1 for Normal Close
Fig 2 for Normal Open