Flow Sensor
Please be sure to read before handling the product. Please refer to "safety instructions", "common safety instructions for products listed in this manual", "common safety instructions for flow controller" from page 24 through 35.
>
>
>
http://www.pisco.co.jp
MODE key
・
Use to enter each setting mode
・
Use to return to the flow display
・
Use to turn off peak hold operation
△
(UP) key
・
Sequentially displays the CH1 data when the flow rate
is displayed.
・
Display the maximum value during peak hold operation
・
When selecting a mode, determines the mode
・
When setting each data, using count up numbers, etc.
▽
(DOWN) key
・
Sequentially displays the CH2 data when the flow rate
is displayed.
・
Display the minimum value during peak hold operation
・
When setting each data, using count down numbers, etc.
Main display (green/red)
・
Display set value and flow rate
・
Display color can be changed.
・
Display upper 3 digits during
accumulated flow rate display
Sub display (green/red)
・
Display flow direction and operating
status
・
Display color can be changed
・
Display lower 4 digits during
accumulated flow display
Flow rate unit display (green)
・
Display flow rate unit
Output (OUT1) display (green)
・
Illuminate when CH1 output is ON
・
Flash when over current is
detected.
Output (OUT2) display (green)
・
Illuminate when CH2 output is ON
・
Flash when over current is
detected.
15
Operation method
<
Display example
>
In case of FUS20-NV-100-
□
Indication
LCD display
Real-time flow display
Reverse direction
10L/min(ANR)
*For bidirectional setting (note: one-way directional type indicates “Lo”)
Accumulated flow display
At 99999.99L
*Values will return to "0.00" if it goes beyond "99999.99" (It will be reset.)
■
Display/operating section names and functions