Configure Proper Grounding

Do not connect the earth-ground wire to a gas pipe, water pipe, lightning rod, or telephone earth

wire. Defective grounding can cause an electric shock.

·

Do not install the unit in a place where an inflammable gas could leak. If gas leaks and accumulates

in the area surrounding the unit, it could cause an explosion.

·

Fasten the flare nuts with a torque wrench to the values as specified in this manual. When fastened

too tightly, a flare nut may break after a long period, and cause a leakage of refrigerant.

·

Install an earth leakage circuit breaker depending on the installation place (anywhere that is humid).

If an earth leakage breaker is not installed, it could result in electric shock.

·

Perform the drainage/piping work securely, according to the installation manual.

·

If there is a defect in the drainage/piping work, water from the unit could accumulate and household

goods or items could get wet and/or damaged.

CAUTION

2

Safety 

I

nstructions

·

Do not allow air to enter the refrigeration system or discharge refrigerant when moving the air

conditioner.

·

This appliance is not intended for use by persons (including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision

or instruction concerning use of the appliance by a person responsible for their safety.

·

Children should be supervised to ensure that they do not play with the appliance.

·

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly

qualified persons in order to avoid any hazards.

·

The appliance must be installed in accordance with national wiring regulations.

·

Servicing shall only be performed as recommended by the equipment manufacturer.

·

Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under

the supervision of the person competent and capable in the handling of flammable refrigerants.

·

Means for disconnection, such as circuit breaker, which can provide full disconnection in all poles,

must be incorporated in the fixed wiring in accordance with the wiring rules.

·

It is necessary to allow the disconnection of the appliance from the supply after installation.

Ensure the disconnection of the appliance from the supply when servicing or performing maintenance,

a

 disconnection with a locking system in the isolated position must be configured.

·

The method of connection of the appliance to the electrical supply and interconnection of

separate components, and the wiring diagram with a clear indication of the connections and

wiring to external control devices and supply cord are detailed in the sections that follow.

·

Details of type and rating of circuit breakers / ELB is detailed in the sections that follow.

·

The dimensions of the space necessary for proper installation of the appliance, including the minimum

permissible distances to adjacent structures, is detailed in the sections that follow.

·

This appliance is intended for use by experts or trained users in shops, in light industry and

on farms, or for commercial use by laypersons.

·

Instructions on additional charging of refrigerant are detailed below.

·

Be sure to cut off the main power supply before the installation of indoor electronic PCB or wiring.

Otherwise, there is a risk of electric shock.

·

The device should be compliant with all state provisions for installation wiring.

·

The outdoor unit installation location should be compliant to all safety principles, avoiding locations

susceptible to people or other small animals coming into contact with electrical components.

Keep the outdoor unit and the surrounding environment clean and tidy.

·

When installing or relocating the unit, make sure that no substance other than the specified refrigerant

(R410A) enters the refrigerant circuit.

Any presence of foreign substance, such as air, can cause abnormal pressure rises or explosions.

Summary of Contents for YH1824GHFD18RT2

Page 1: ...ore installing or operating your new air conditioning system Be sure to save this manual for future reference Installation Manual CENTRAL SPLIT AIR CONDITIONER HIGH EFFICENCY CONDENSING UNIT Models YH1824GHFD18RT2 YH3036GHFD18RT2 YH4248GHFD18RT2 YH4860GHFD18RT2 R 410A REFRIGERANT 208 230 V 1 Phase 60Hz 18 SEER ...

Page 2: ...This page intentionally left blank ...

Page 3: ...utions 1 Diagram of Refrigerant Cycle Wiring 3 Refrigerant Flow Diagram 3 Electrical Wiring Diagram 3 Installation Instructions 4 Transportation and Handling Before Installation 4 Installation Location Selection 4 Drainage Elbow and Drain Hose Installation 5 Outdoor Unit Installation 5 Refrigerant Piping 6 Wiring 9 Test Run 11 Mode Outdoor Operation Temperature Range Maximum Minimum Cooling Operat...

Page 4: ... with their respective safety symbols WARNING Hazards or unsafe practices which COULD result in severe personal injury or death CAUTION Hazards or unsafe practices which COULD result in minor personal injury or product or property damage Carefully store the indoor and outdoor unit manuals away for your future reference Installation should be performed only by qualified personnel Improper installat...

Page 5: ...arried out under the supervision of the person competent and capable in the handling of flammable refrigerants Means for disconnection such as circuit breaker which can provide full disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules It is necessary to allow the disconnection of the appliance from the supply after installation Ensure the disconne...

Page 6: ... 60K models Electrical Wiring Diagram L1 L2 PE Power supply Power supply Power supply Thermostat Indoor unit Outdoor unit Power terminal panel OR L2 L2 L1 L1 W1 B C R Y G G R C C B Y W SI W1 SI Note The SI wire between the indoor and outdoor units is not mandatory especially when the outdoor unit is connected to an indoor unit of a different brand It is more energy efficient when the outdoor unit ...

Page 7: ...ft away from the antenna of a TV set or radio An amplifier may be required for the affected device Install the unit horizontallyandlevel Install it in an area not affected by snowfall or blowing snow If areas with heavy snow cannot be avoided install a canopy a pedestal and or some baffle boards Avoid the following places for installation where air conditioner related issues are liable to occur Wh...

Page 8: ...rwise it can cause damage to the appliance or reduce its lifetime Fig 3 Drainage Elbow and Drain Hose Installation Outdoor Unit Installation Install Drainage Elbow and Drain Hose The condensate water may drain from the outdoor unit when the unit operates in heating mode In order to avoid disturbing neighbors and to protect the environment it is necessary to install a drainage elbow and a drain hos...

Page 9: ...re connecting pipes 3 Piping thickness and material of the pipe are shown as below Refrigerant Additional Charge The unit has been pre loaded with refrigerant but if exceeding 25 ft 7 6m of line set additional refrigerant R410A is required 24K 36K Additional refrigerant charge L 25 ft 0 38 oz ft 48K 60K Additional refrigerant charge L 25 ft 0 60 oz ft 2 Piping material The shorter the refrigerant ...

Page 10: ...ing brazing c After brazing cool joint using the wet rag Installation Instructions Welding Torch Baffle Wet Cloth Piping Insulation Procedure Insulation field supplied 3 After finishing connection of the refrigerant pipes keep it warm using the insulation material as depicted in the figure on the right For the outdoor unit side insulate every piping end including valves Cover piping joints with pi...

Page 11: ...halogen leak detector to check the flare nut and brazing points of leak Use foam that does not generate ammonia NH3 in the reaction Indoor Unit Outdoor Unit Manifold Valve Pressure Gauge Vacuum Pump Fig 9 2 Turn the cylinder upside down when filling Stand the cylinder upright when filling There is a siphon pipe inside so the cylinder need not be upside down to fill with liquid Filling Using a Cyli...

Page 12: ...at unprotected parts and in the worst case scenario a fire will occur Prevent the wirings from touching the refrigerant pipes plate edges and electrical parts inside the unit If not done so the wires will be damaged and in the worst case scenario a fire will occur Install an ELB Electric Leakage Break at the power source If an ELB is not used it can cause electric shock or fire at the worst case s...

Page 13: ...ansmitting Cable to wired controller 1 Remove the screws maintenance plate and the valve cover 2 Pass transmitting cable and power supply through the two holes on the right side plate 3 Fasten the conduit connection to the right side plate using the lock nut 4 Connect the transmitting cable and power supply to the terminal 5 Secure the transmitting cable and power supply together with the clamp ti...

Page 14: ...ns are done If you still have any trouble please contact the local technical service center of our company for further information CAUTION Test Run Electrical Data Max Running Current A REFER TO NAMEPLATE Note 1 Follow local codes and regulations when selecting field wires All of the above are the minimum wire size 2 When transmitting cable length is longer than 262ft 80m the next larger wire size...

Page 15: ...This page intentionally left blank ...

Page 16: ...er Davis HVAC International Inc Parker Davis HVAC International Inc 3250 NW 107 Avenue Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 E mail info pdhvac com Website www pdhvac com Pioneer product line parts and supplies are available online for convenient ordering at www highseer com www pioneerminisplit com Scan the below code to visit our support page where you can find more installation m...

Reviews: