1. This air conditioner uses new refrigerant HFC (R410A).

2. Since the max. working pressure is 550 psig (3.8MPa) [R22:450 psig (R22:3.1MPa)], some of the 

piping and installation and service tools are special.

3. This air conditioner uses the following power supply: ~208/230V, 60Hz.

4. The outdoor unit must be installed with an indoor unit equipped with TXV, and ensure that the TXV 

can be opened to the maximum angle while running heating mode.

5. The outdoor unit must be matched with an indoor unit using refrigerant R410A.

6. For 24K outdoor unit, it must be connected with 18K~24K indoor units.

For 36K outdoor unit, it can be connected with 30K~36K indoor units.

For 48K outdoor unit, it can be connected with 42K~48K indoor units.

For 60K outdoor unit, it can be connected with 48K~60K indoor units.

7. Specified filter drier is required on the liquid pipe when connecting the units.

8. Be sure that servicing equipment and replacement components are applicable for R-410A 

refrigerant.

9. Do not discharge R410A refrigerant into the air, and when recovering it, the cylinder service 

pressure rating must be over 550 psig. R410A refrigerant systems should be charged with liquid 

refrigerant and the service pressure rating of the hoses used must be over 750 psig.

10. Leak detectors should be designed to detect HFC refrigerant.

11. R410A refrigerant is only compatible with POE oils, which could absorb moisture rapidly, so do not 

expose it to the air, to prevent damage of certain plastics materials.

12. Replace all the filter driers after maintenance.

·

Be sure to use a dedicated power circuit, and do not put other loads on the power supply.

·

Be sure to read these SAFETY PRECAUTIONS carefully before installation.

·

Be sure to comply with SAFETY PRECAUTIONS of installation manual, since it contains important

safety instructions. Definitions for identifying hazard levels are provide

d

 below with their respective

safety symbols.

        WARNING

Hazards or unsafe practices which COULD result in severe personal injury or death.

        CAUTION

: 

Hazards or unsafe practices which COULD result in minor personal injury or product 

or property damage.

·

Carefully store the indoor and outdoor unit manuals away for your future reference.

·

Installation should be performed only by qualified personnel.

Improper installation can cause water leakage, electrical shock, or fire.

·

Install the air conditioner on a solid base that can support all of the unit's weight.

An inadequate base or incomplete installation may cause injury if the unit falls off the base.

·

Use the specified type of wire for electrical connections safely between the indoor and outdoor units.

Firmly

clamp the interconnecting wires so that their terminals can receive no external stresses.

·

For wiring, use a cable long enough to cover the entire distance with no connection.

Do not connect multiple devices to the same AC power supply.

Otherwise, there is risk that due to bad contact or poor insulation, it can exceed the allowable current

and cause a fire or electric shock.

·

After installation is complete, perform a leak check to make sure that no refrigerant is leaking out.

If the refrigerant gas leaks internally, toward the heater, or externally towards any stove flames, it can

generate harmful substances.

·

Perform the installation securely referring to the installation manual.

Incomplete installation could cause personal injury due to fire, electric shock, the unit falling

,

 or

leakage of water.

·

In accordance with installation instructions for electrical-related work, use a dedicated

 

electrical line.

·

If the power supply circuit capacity/electrical work is not proper, it may cause a fire or electric shock.

·

Attach the electrical cover to the indoor unit and the service panel to the outdoor unit securely

.

·

If

 the electrical covers on the indoor unit or the service panel of the outdoor unit are not attached

securely, it could result in a fire

,

 or an electric shock due to dust, water, etc.

WARNING

Safety 

P

recautions

1

Summary of Contents for YH1824GHFD18RT2

Page 1: ...ore installing or operating your new air conditioning system Be sure to save this manual for future reference Installation Manual CENTRAL SPLIT AIR CONDITIONER HIGH EFFICENCY CONDENSING UNIT Models YH1824GHFD18RT2 YH3036GHFD18RT2 YH4248GHFD18RT2 YH4860GHFD18RT2 R 410A REFRIGERANT 208 230 V 1 Phase 60Hz 18 SEER ...

Page 2: ...This page intentionally left blank ...

Page 3: ...utions 1 Diagram of Refrigerant Cycle Wiring 3 Refrigerant Flow Diagram 3 Electrical Wiring Diagram 3 Installation Instructions 4 Transportation and Handling Before Installation 4 Installation Location Selection 4 Drainage Elbow and Drain Hose Installation 5 Outdoor Unit Installation 5 Refrigerant Piping 6 Wiring 9 Test Run 11 Mode Outdoor Operation Temperature Range Maximum Minimum Cooling Operat...

Page 4: ... with their respective safety symbols WARNING Hazards or unsafe practices which COULD result in severe personal injury or death CAUTION Hazards or unsafe practices which COULD result in minor personal injury or product or property damage Carefully store the indoor and outdoor unit manuals away for your future reference Installation should be performed only by qualified personnel Improper installat...

Page 5: ...arried out under the supervision of the person competent and capable in the handling of flammable refrigerants Means for disconnection such as circuit breaker which can provide full disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules It is necessary to allow the disconnection of the appliance from the supply after installation Ensure the disconne...

Page 6: ... 60K models Electrical Wiring Diagram L1 L2 PE Power supply Power supply Power supply Thermostat Indoor unit Outdoor unit Power terminal panel OR L2 L2 L1 L1 W1 B C R Y G G R C C B Y W SI W1 SI Note The SI wire between the indoor and outdoor units is not mandatory especially when the outdoor unit is connected to an indoor unit of a different brand It is more energy efficient when the outdoor unit ...

Page 7: ...ft away from the antenna of a TV set or radio An amplifier may be required for the affected device Install the unit horizontallyandlevel Install it in an area not affected by snowfall or blowing snow If areas with heavy snow cannot be avoided install a canopy a pedestal and or some baffle boards Avoid the following places for installation where air conditioner related issues are liable to occur Wh...

Page 8: ...rwise it can cause damage to the appliance or reduce its lifetime Fig 3 Drainage Elbow and Drain Hose Installation Outdoor Unit Installation Install Drainage Elbow and Drain Hose The condensate water may drain from the outdoor unit when the unit operates in heating mode In order to avoid disturbing neighbors and to protect the environment it is necessary to install a drainage elbow and a drain hos...

Page 9: ...re connecting pipes 3 Piping thickness and material of the pipe are shown as below Refrigerant Additional Charge The unit has been pre loaded with refrigerant but if exceeding 25 ft 7 6m of line set additional refrigerant R410A is required 24K 36K Additional refrigerant charge L 25 ft 0 38 oz ft 48K 60K Additional refrigerant charge L 25 ft 0 60 oz ft 2 Piping material The shorter the refrigerant ...

Page 10: ...ing brazing c After brazing cool joint using the wet rag Installation Instructions Welding Torch Baffle Wet Cloth Piping Insulation Procedure Insulation field supplied 3 After finishing connection of the refrigerant pipes keep it warm using the insulation material as depicted in the figure on the right For the outdoor unit side insulate every piping end including valves Cover piping joints with pi...

Page 11: ...halogen leak detector to check the flare nut and brazing points of leak Use foam that does not generate ammonia NH3 in the reaction Indoor Unit Outdoor Unit Manifold Valve Pressure Gauge Vacuum Pump Fig 9 2 Turn the cylinder upside down when filling Stand the cylinder upright when filling There is a siphon pipe inside so the cylinder need not be upside down to fill with liquid Filling Using a Cyli...

Page 12: ...at unprotected parts and in the worst case scenario a fire will occur Prevent the wirings from touching the refrigerant pipes plate edges and electrical parts inside the unit If not done so the wires will be damaged and in the worst case scenario a fire will occur Install an ELB Electric Leakage Break at the power source If an ELB is not used it can cause electric shock or fire at the worst case s...

Page 13: ...ansmitting Cable to wired controller 1 Remove the screws maintenance plate and the valve cover 2 Pass transmitting cable and power supply through the two holes on the right side plate 3 Fasten the conduit connection to the right side plate using the lock nut 4 Connect the transmitting cable and power supply to the terminal 5 Secure the transmitting cable and power supply together with the clamp ti...

Page 14: ...ns are done If you still have any trouble please contact the local technical service center of our company for further information CAUTION Test Run Electrical Data Max Running Current A REFER TO NAMEPLATE Note 1 Follow local codes and regulations when selecting field wires All of the above are the minimum wire size 2 When transmitting cable length is longer than 262ft 80m the next larger wire size...

Page 15: ...This page intentionally left blank ...

Page 16: ...er Davis HVAC International Inc Parker Davis HVAC International Inc 3250 NW 107 Avenue Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 E mail info pdhvac com Website www pdhvac com Pioneer product line parts and supplies are available online for convenient ordering at www highseer com www pioneerminisplit com Scan the below code to visit our support page where you can find more installation m...

Reviews: