Pioneer WYD009AL3JAR-L Service Manual Download Page 9

 Air Conditioner Service Manual 

z

Press the Timer button(‘h’ flashes). 

z

Use the  button to select the time at which the air conditioner must activate (between 0 and 10 

hours can be set at every half hour-between 10 and 24 hours can be set at every hour). 

z

Press the Timer button (‘h’ stops flashing) and the preset time appears in the display. 

z

Press the Timer button again to delete the selected data from the memory. 

Note : If no buttons are pressed during the programming of the timer function, thee remote control will 

switch off automatically after 10 seconds. 

(2)  To switch the air conditioner off at the desired time, follow the procedure specified below (the remote control 

and air conditioner are switched off): 

z

Press the timer button. 

z

Use the  button to select the time at witch. 

13. EMERGENCY Operation 

When the EMERGENCY Operation switch is pressed once, COOLING mode is selected and if in 3 seconds the 

EMERGENCY Operation switch is pressed again, mode is selected. Then pressed once again, the unit is switch 

off. 

When the remote controller is missing, has failed or the batteries run down, press the EMERGENCY Operation 

switch on the front of the indoor unit. The unit will start. 

The first 30 minutes of operation will be the test run operation. The operation is for servicing. The indoor fan runs 

at high speed and the system is in continuous operation. The thermostat is ON and the timer is reset to normal. 

After 30 minutes of test run operation the system shifts to AUTO COOLING/HEATING mode, and the indoor fan 

runs in automatic speed. The operation continues unit the EMERGENCY operation switch is pressed or a button 

on the remote controller is pressed and normal operation will start. 

NOTE: Do not press the EMERGEMCY Operation switch during normal operation. 

14.  AUTO RESTART Function(Option)

 

1.When the indoor unit is controlled with the remote controller, the operation mode, set temperature, and the fan 

speed are memorized by the indoor electric control PCB. The AUTO RESTART function sets to work the 

moment power has restored after power failure. Then, the unit will restart automatically. 

2. How to set the AUTO RESTAR function. 

z

Press the emergency switch and power supply to the PCB following, hold 10 seconds and the buzzer will 

beep three times. The AUTO-RESTAR is set. 

z

Do the operation again, the buzzer will beep four times and the AUTO-RESTAR function is cancelled. 

15. 

Failure Display and Handling

 

a) Failure 

Display 

When the controller has failure, the buzzer will sound long for three times, and displays the failure from the 

failure lamp. 

b) Failure 

Code 

If have the digital pipe that displays the failure code for digital pipe, or display for the run lamp. 

Type of failure 

The lamp flash 

Display of digital pipe 

The failure of room temperature sensor 

Once/cycle 

E1 

The failure of indoor pipe temperature sensor 

Twice/cycle 

E2 

The failure of indoor fan motor 

6 times/cycle 

E6 

c) Failure 

Handling 

z

When the room temperature sensor or the indoor pipe temperature sensor has a failure, the system will be 

shut off, the compressor will be OFF, and the outdoor fan and the indoor fan will be OFF. The system 

doesn’t receive the signal of remoter controller except the signal of shut off it. When the failure 

disappear, the controller can operate in normal mode. before this, presses the “ON/OFF” to start the 

system, and it will operate in COOLING or HEATING for 30 minutes, and follows shut off. During 

Summary of Contents for WYD009AL3JAR-L

Page 1: ... No TE1307 Models WYD009AL3JAR L WYD012AL3JAR L WYD018GL3JAR L WYD024GL3JAR L 1 IMPORTANT NOTICE 2 OPERATION DETAILS 3 ELECTRICAL SCHEMATIC DIAGRAM 4 EXPLOSION VIEW 5 PARTS LIST WALL MOUNTED SPLIT TYPEAIR CONDITIONERS CONTENTS 1 2 11 13 16 ...

Page 2: ...not be responsible for the interpretation of this information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or improvement without any prior notice The accurate specifications are presented on the nameplate label How to order spare parts To have your order filled promptly and correctly ple...

Page 3: ...ote controller 6 2 5 3 7 1 Air Conditioner Service Manual Operation Details Remote Control The remote controller is not preset as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time after the remote controller replace batteries or is energized the arrowhead will flash on the front of Heat or Cool on LCD of the remote controller User can preset the remote controller type depending o...

Page 4: ...ressor Outdoor fan OFF when the indoor pipe temperature is ı Outdoor fan ON when the indoor pipe temperature is İ118 4 Compressor OFF when the indoor pipe temperature is ı Compressor ON when the indoor pipe temperature is İ118 4 2 I Feel Mode Operation 1 When the I Feel mode is selected the operation mode and initial set temperature are determined by the initial room temperature at start up of the...

Page 5: ...setting temperature the system will set the temperature at automatically with the AUTO FAN speed 2 When selecting the HEATING mode operation the system will operate according to the setting by the remote controller and the operation is as following Set Temp ˇ1 8 Set Temp ˉ1 8 Room Temp Time More than 2 min More than 2 min More than 2 min More than 2 min More than 2 min Compressor ON OFF ON OFF ON ...

Page 6: ... the IPT is less than for 2 minutes When the defrosting operation time on this condition exceeds 8 minutes it will terminate C After the compressor operates continuously for 20 minutes and the IPT is less than 73 4 or from the last time of defrosting operation is 50 minutes or more interval When the defrosting operation time on this condition exceeds 10 minutes it will terminate z When the JC isn ...

Page 7: ...e the set temperature will be raised by 1 1 hour later and by 2 hour later z When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 hour later z After the System operates in SLEEP mode for 8 hours it will stop automatically 9 Fan motor control 1 Rotational frequency feedback control The indoor fan motor is equipped with a rotational frequency s...

Page 8: ...on and then set to the desired angle The positioning is decided as follows z When the ON OFF button is pressed z When the vane control is change from AUTO to MANUAL z When the SWING is finished z When the test run starts z When the power supply turns ON 3 The auto vane changes as follows by pressing the VANE CONTROL button 4 VANE AUTO mode In vane auto mode the microprocessor automatically determi...

Page 9: ...pressed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGEMCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When the indoor unit is controlled with the remote controller the operation mode set temperature and the fan speed are memorized by the indoor electric control PCB The AUTO RESTART function sets to work th...

Page 10: ...l of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again z When the indoor fan motor is failure the compressor is stopped the outdoor fan and indoor fan is stopped and display the failure The system doesn t receive the signal of remoter controller except the signal of shut it off d Display Of The ...

Page 11: ...Wiring diagram Model 5 5 Indoor unit Outdoor unit ...

Page 12: ...Wiring diagram Model 5 Indoor unit Outdoor unit ...

Page 13: ...Wiring diagram Model 5 Indoor unit Outdoor unit ...

Page 14: ... motor is properly mounted If the blower is spinning freely and E6 code is still displayed change the fan motor If this does not resolve the problem change the indoor unit s controller card Symptom HEAT Mode is missing on the remote control screen Remote skips the heat mode Reason Remote controller was erroneously setup as cooling only Solution Reset the remote controller Remove and reinsert the b...

Page 15: ...heck for operating pressures and assure the system has no refrigerant leaks Symptom System does not start cooling or heating as soon as it is started Reason System is in protection time delay mode Solution When the system is started the compressor does not start immediately There is a 3 minute time delay for protection Symptom Indoor unit seems totally dead No lights Reason Power connection from t...

Page 16: ...he system will stop defrosting and switch to heating mode again Additionally system cannot operate in heating mode at outdoor temperatures below 15F which will be in efficient and causes more frequent freezing than normal Otherwise check for low refrigerant charge and measure the pressures and obtain proper levels Clean the coil if needed Symptom Circuit breaker tripping Reason Damaged breaker low...

Page 17: ...door unit It should be always 110 120V b Check the voltage between the L and N terminals on the outdoor unit It should be always 110 120V c Check the voltage between two L terminals left and right on the outdoor unit It should always 0 V d For the compressor to run the voltage between the 1 and N terminals at BOTH the outdoor and indoor units terminal blocks must be measured as 110 120 VAC e For t...