PDP-R06G
30
1
2
3
4
1
2
3
4
C
D
F
A
B
E
3. MAIN NG
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
I
M A I N
M A I
S U B
N
N G
N F O R M A T I O N
1
M
–
– – – – – –
– – – – – –
0 0 1 5 1 H 2 1 M
0 0 0 3 1 H 5 0 M
0 0 0 1 3 H 0 3 M
0 0 0 0 2 H 5 2 M
0 0 0 0 1 H 5 8 M
0 0 0 0 0 H 0 7 M
2
M
A
–
I I C
F E 2
3
M A –
I I C
A V – SW
4
S R L
5
M A I N
6
T E M P 2
– – – – – –
0 0 1 5 1 H 2 1 M
M R – PW R
7
8
– 1 1
V D
I C
1
6 0 1 – N T V – J H S 6
¶
Media Receiver NG information
OSD: MAIN
OSD: SUB
Cause of Shutdown
MODULE
----
Abnormally in Module microcomputer communication
MA-SRL
Abnormally in 3-wire Serial Communication of the Main microcomputer.
IF
Communication failure of IF microcomputer
MULTI1
MANTA communication failure (MULIT1)
I/P
MANTA communication failure (I/P)
D-SEL
MANTA communication failure (D-SEL)
MA-IIC
Abnormally in Main microcomputer IIC communication
FE1
Analog Tuner 1 (Front End 1)
AV-SW
AV Switch
RGB-SW
RGB Switch
M-VDEC
Main VDEC
S-VDEC
Sub VDEC
ADC
AD/PLL
HDMI
HDMI
PLK-T
TMDS Tx
PLK-R
TMDS Rx
TX-COM
M2 Communication
TX-BSY
M2 Busy
MA-EEP
64k EEPROM
MAIN
Abnormally in Main microcomputer communication
FAN
Fan stopped
TEMP2
Abnormally high temperature of the MR.
A
3