Special installation (Ceiling embedding)
3.4.9 Ceiling embedding
This display is designed to accommodate embedding in a ceiling. Note that the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following requirements:
1
Use a mounting fixture with a shape that does not block ventilation holes on the back or disturb ventilation in
any way, and secure the display at four or more points. Moreover, when installing this display, ensure that the
deformation such as twisting and bending of this display can be kept within 1 mm. Otherwise, it is likely that
PDP panel will cause cracks.
2
Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3
Installation conditions and ambient operating temperatures:
(1) When the space above the ceiling is not enclosed (If there is no obstruction within 300 mm from the backside):
A
A
Intake (holes other than
that of fan)
Exhaust
A
100 mm
100 mm
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
Clearance A to the wall
VIDEO
Machintosh (66.7Hz)
VGA (60HZ)
VGA (72.8Hz, 75Hz)
150 mm or less
0~40
°
C
0~40
°
C
0~35
°
C
Working temperature requirements
100 mm
100 mm
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
* When mounting the down converter (PDA-4003), the same working temperature conditions apply.
Summary of Contents for PDK-5008
Page 5: ...5 Features ...
Page 11: ...11 Remote control ...
Page 21: ...21 Installation procedure ...
Page 57: ...57 Special installation Installation under the floor ...
Page 85: ...85 How to mount standard optional items PDK 4001 ...
Page 91: ...91 How to mount standard optional items PDK 4002 ...
Page 97: ...97 How to mount standard optional items PDK 4004 ...
Page 115: ...115 How to mount standard optional items PDK 5008 PDK 5008FT ...
Page 153: ...153 How to mount standard optional items Precautions for installing the optional speaker ...
Page 161: ...161 Before making adjustments ...