44 THIS ITEM IS NOT AVAILABLE. PLEASE CONTACT PIONEER FOR INFORMATION
4.4.2 Assembling and installing the mounting hardware, and mounting the plasma display
1) Preparations
You will need the following tools. Make sure you have them at hand before beginning work.
• Wrench or spanner (subtense 12 mm)
• Hexagonal wrench (subtense 4 mm, for M5 bolts)
• Hexagonal wrench (subtense 5 mm, for M6 bolts)
• Hexagonal wrench (subtense 6 mm, for M8 bolts)
• Hexagonal wrench (subtense 8 mm, for M10 bolts)
You’ll also need tools for ceiling work.
2) Assembling and installing the mounting hardware
1
Confirm that the monitor brackets (left and right) are firmly mounted to the monitor frame and insert the center rod
through monitor frame and the spacer into the post COMP. Secure the post COMP and the center rod with two
hexagonal socket head bolts (M8 x 75).
2
Tighten the vibration-preventing hexagonal socket head bolt (M5 x 16).
3
Select the installation site, then apply the supplied pattern to the ceiling, drill the suitable holes, and mount the
ceiling flange COMP. The appropriate types of screws and other display/mounting components will depend on the
strength and composition of the particular ceiling.
4
Insert the post COMP into the ceiling flange COMP and secure the two with two hexagonal socket head bolts (M10
x 85).
5
Tighten the vibration-preventing hexagonal socket head bolt (M6 x 10).
• Firmly tighten all bolts.
• After mounting the mounting hardware, but before mounting the plasma display, confirm the strength of the
mount portion of the ceiling.
• For additional safety, use the holes in the ceiling flange COMP, as shown. (Use parts strong enough to support the
weight of the display)
THIS ITEM IS NOT AVAILABLE. PLEASE CONTACT PIONEER FOR INFORMATION
Example:
Securing to a foundation ceiling with
shackle and safety wire.
Ceiling flange COMP
Anchor
Foundation ceiling
Shackle
Safety wire
Bolt
NOTE: Safety wires serve as important backups in keeping the unit securely mounted.
Summary of Contents for PDK-5001
Page 5: ...5 Features ...
Page 11: ...11 Main Switch Main Unit Operation Panel Light Sensor for the Remote External Dimensions ...
Page 15: ...15 Remote Control Unit ...
Page 47: ...47 THIS PAGE IS INTENTIONALLY BLANK ...
Page 68: ...68 Before Beginning Adjustments ...
Page 84: ...84 Menu Mode ...
Page 102: ...102 Integrator Mode ...
Page 112: ...112 Combination Cable Connection ...