108
RS-232C Adjustment Mode
3) <GET> (GET STATUS) — The status of various settings is transmitted in the following formats:
• Output items
[Example of output]
=
Setting status when the signals to the
left are issued
(1) STX (02H)
(2) Version of microcomputer software (5 bytes) [5435A]
=
Version A
(3) Input function status
(3 bytes) [IN1]
=
INPUT 1
(4) Color-mode setting status
(3 bytes) [CM1]
=
COLOUR MODE 1
(5) Full auto zoom setting status
(3 bytes) [AZN]
=
Full Auto Zoom: OFF
(6) Screen-size setting status
(3 bytes) [SM2]
=
Screen-Size Setting: FULL
(7) Auto power off setting status
(3 bytes) [APN]
=
Auto Power Off: OFF
(8) 3-dimensional Y/C Separator Setting Status
(3 Bytes) [ YCM]
=
3D Y/C MODE: MOTION
(For U.S. models and Taiwanese models)
(9) COLOUR SYS Setting Status
(3 Bytes) [TVA]
=
COLOUR SYS: AUTO
(For EURO models only)
(10) Status of connected equipment settings and input signal format settings
(3 bytes) [BBY]
=
INPUT SETTING: VIDEO; SIGNAL: RGB
(11) Clamp position setting status
(3 bytes) [CL1]
=
CLAMP: MODE 1
(12) ABL setting status
(3 bytes) [ABY]
=
ABL: ON
(13) MP mode setting status
(3 bytes) [MPY]
=
MP: ON
(14) KEY LOCK/UNLOCK
(3 bytes) [KLN]
=
UNLOCK (available either from the remote
or the operating panel of the main unit)
(15) OSD display setting status
(3 bytes) [DIN]
=
OSD not displayed
(16) Mirror mode setting status
(3 bytes) [MMZ]
=
MIRROR MODE: XY
(17) Dummy data
(3 bytes)
(18) STD-RGB setting status
(3 bytes) [NRY]
=
STD-RGB: ON
(19) ETX (03H)
NOTES: • Refer to P.74 to P.94 and P.113 for the setting for each item.
• When the input function is INPUT 1, the dummy data is issued for:
(10) Status of connected equipment settings and input signal format settings
(11) Clamp position setting status
(12) ABL setting status
(13) MP mode setting status
• When the input function is INPUT 2, or INPUT 3 or 4 and in the VIDEO setting, the dummy data is issued for:
(8) 3-dimensional Y/C separator setting status
(11) Clamp position setting status
(12) ABL setting status
(13) MP mode setting status
• When the input function is INPUT 3 or 4 and in the PC setting, the dummy data is issued for:
(8) 3-dimensional Y/C separator setting status
Summary of Contents for PDK-5001
Page 5: ...5 Features ...
Page 11: ...11 Main Switch Main Unit Operation Panel Light Sensor for the Remote External Dimensions ...
Page 15: ...15 Remote Control Unit ...
Page 47: ...47 THIS PAGE IS INTENTIONALLY BLANK ...
Page 68: ...68 Before Beginning Adjustments ...
Page 84: ...84 Menu Mode ...
Page 102: ...102 Integrator Mode ...
Page 112: ...112 Combination Cable Connection ...