GEX-P10XMT/XN/UC
42
1
2
3
4
1
2
3
4
C
D
F
A
B
E
4.4 RS INFO
Display format : [ X X X X Y Y Y Y ]
X : Number of error correction bytes from Read-Solomon decryption (four digits of hexadecimal value).
Y : Number of error frames from Read-Solomon decryption (four digits of hexadecimal value).
Each piece of information becomes effective following the initialization of CDEC. The updating interval is 432 ms.
Turn Integrating Mode ON/OFF by holding down “4” key while RS INFO is displayed.
Reset integrating value by holding down “4” key while RS Integrating Mode is ON.
Display example : If the error correction bytes = 0 x 0040, while the error frames = 0 x 0010, the display will
show [ 0 0 4 0 0 0 1 0 ].
4.5 TUNER INFO
Display format : [ X _ Y Y Y Y _ Z ]
X : Synchronous ensemble ( A / B ).
_ : Spacing character.
Y : LOCK/UNLOCK status of PLL ( L K _ _ / U N L K ).
Z : RF AGC status of ZIF ( Engaged = 1 / Not Engaged = 0 ).
The information becomes effective following the synchronization process during the system start up.
The updating interval is 16 ms.
Display example : If the PLL is locked with ensemble A, the display will show [ A _ L K _ _ _ 1 ].
4.6 ERROR CODE
Display format : [ E R R O R _ X X ]
_ : Spacing character.
X : Error occurring (two digits of hexadecimal value). The upper digit is for the major (physical) error, while the
lower digit is for the minor error (temporary or partial errors). Refer to the following table for details:
No minor error.
The line for communicating with CDEC.
The line for communicating with SSDEC.
No SSDEC response (DSP core freeze).
100% error of Vitarbi signal decryption.
Not activated.
Not authorized.
No major error.
Antenna not connected.
Short circuited antenna cable.
PLL cannot be synchronized (RF circuit failure).
Undefined.
Defective NVM inside CAP.
Defective CAP (including situations where CAP is not
connected).
Unknown DSP core software version.
Defective DDC
CAP not bound
Code value
Description
Error location
Major Minor
0
1
2
3
4
5
6
0
1
2
3
4
5
6
7
8
9
Display example : If the antenna is not connected, the display will show [ E R R O R _ 1 4 ]
(no signal due to unconnected antenna).
No Error
CDEC Communication Error
SSDEC Communication Error
SSDEC No Response
No Signal
Activation Required
Authorization Required
No Error
ANTENNA No Connect
ANTENNA Short
PLL UNLOCK
Reserved
NVM Error
CAP Error
Version Unknown
DDC Fail
Unbound
Summary of Contents for GEX-P10XMT - Satellite Radio Tuner
Page 14: ...GEX P10XMT XN UC 14 1 2 3 4 1 2 3 4 C D F A B E A a A b A a A b 1 2 A a 1 2 1 ...
Page 15: ...GEX P10XMT XN UC 15 5 6 7 8 5 6 7 8 C D F A B E A a A b A a A b 1 2 A a 1 2 2 B CN502 ...
Page 17: ...GEX P10XMT XN UC 17 5 6 7 8 5 6 7 8 C D F A B E A a A b A b 1 2 2 LPF ...
Page 24: ...GEX P10XMT XN UC 24 1 2 3 4 1 2 3 4 C D F A B E 3 4 TUNER UNIT B RF XM ANTENNA ...
Page 25: ...GEX P10XMT XN UC 25 5 6 7 8 5 6 7 8 C D F A B E B 1 2 A CN301 B TUNER UNIT CLK BUFFER ...