Adjusting conditions
Adjustments should be carried out in the procedures of A to C specified below. However, any
adjustments other than the items A to C below are not required.
A. When the “PDP module
(PDP-NP61C2MF01)
” is replaced, adjustments
should conform to the
adjusting items of [1 and 2] specified below.
B. When the “POWER UNIT” is replaced, adjustments should conform to the
adjusting item of [2] specified below.
C. When the “MAIN PWB” is replaced, adjustments should conform to the
adjusting item of [3] specified below.
■
Adjusting items
1. Clearing of the usage time (Using the remote control)
(1) Press the keys in the order of [POWER ON]
→
[POWER ON]
→
[EXIT]
→
[DISPLAY] in order to
enter the factory adjustment menu.
(2) Press the [MENU/ENTER] key to select the [USAGE TIME] menu (8/11). Then, the integrated time
[34567 (hours)] (example) accumulated till the present time is displayed when the main power supply
is turned on (except for the standby mode).
(3) When the keys are pressed in the order of [MUTE]
→
POSITION/CONTROL [ ]
→
POSITION/CONTROL [ ]
→
[OFF TIMER], the display is cleared to [00000H]. At that time, the
characters of [RESET] are displayed for about 5 seconds on the right side of time display.
USAGE TIME
34567H
232C-ALARM RX 0
T X 0
[MENU/ENTER] NEXT [EXIT] PREV 8/11
USAGE TIME
00000H RESET
232C-ALARM RX 0
T X 0
[MENU/ENTER] NEXT [EXIT] PREV 8/11
31