NEC Plasma Display
Picture Defect
High Voltage Board
OK: Short
NG: Open
Glass Fuse (F302)
(Note) Typical symptom are only shown.
Another Symptom might appear.
Symptom:No Picture(Priming flash).
Cause/
Countermeasure
: ①F302 open⇒
Exchange High Voltage Board.
56