OK: Open
NG: Short-
circuited,
OK: Short-
circuited,
NG: Open
Failure diagnosis of the Data IC
Failure symptom: The image in any block of the screen is not displayed.
Chip fuse (FU701) at the
upper-right corner of the digital
PKG
CN2
CN3
CN8
CN8
CN8
CN8
CN8
CN 2
CN 3
Check with a tester between Pin 5 or 6 (Vd line of Data IC)
and ground of each Signal Relay PKG.
Failure diagnosis of the Digital PKG
28