ERR RATE :
∗
.
∗
e-
∗
• While the User Operation screen is displayed, press the ESC then DISP keys, then the DIG/ANA
key twice, in that order.
• While subscreen 1 of the first screen is displayed, press the DIG/ANA key.
[How to enter]
Press the ESC key.
[How to quit]
(3) Simple Error Rate Measurement (Subscreen 2)
[Measurement procedures]
1
Display subscreen 2.
2
Load the Test disc (GGV1025).
3
Judge the results of the error rate measurement by
referring to Table 1 on page 89.
[Tips]
During VR mode playback, the average value of the past 10 VOBUs is displayed. During DVD-Video or Video mode
playback, the average value of the past 256 sectors is displayed.
During VR mode playback, the speed ratio of the drive (/: normal, no indication: double speed) is also displayed.
Subscreen 2
1) AGC voltage (AGC Volt)
The gain controlled by the tuner is monitored to infer the input electric field intensity.
(The accuracy of inference differs depending on the product.)
Field Intensity
AGC VOL
Intense field area
(Clear image)
Less intense field area
(Noise may be generated.)
Weak field area
(Much noise. EPG/VPS/PDC sometimes cannot be
obtained.)
Very weak field area
(Image damaged. EPG/VPS/PDC cannot be obtained.)
70 dB
µ
or more
3100 mV or less
50 dB
µ
or more
70 dB
µ
or less
3100 - 4400mV
30 dB
µ
or more
50 dB
µ
or less
4400 mV or more
(It is unable to discriminate
under the weak field area.)
30 dB
µ
or less
4400 mV or more
(It is unable to discriminate.)
Tips:
For good reception, the field intensity must be 50 dB
µ
or more (AGC Volt 4400 mV or less).
For accurate measurement, use a field intensity meter.