Mode 6 : Volume Test . “VOLTEST”
• Mode to confirm analog to digital translation value of rotary volume on operation panel by lighting Level Meter LED.
• In this mode, to display the value of two or more rotary volumes with one level meter LED, each rotary volume is
divided into four groups.
Those groups is changed by pressing BEAT UP or DOWN buttons.
• group 1
Rotary volume that can be confirmed
• CH1 HI, CH2 HI, CH3 HI, CH4 HI, MIC HI, MIC LOW
"-26" : Lights off
"+6" :
Full
Illuminate
"-12" : Lights off
"+12" : Full Illuminate
"-26" : Lights off
"+6" :
Full
Illuminate
CH2 HI
CH1 HI
CH2 Level Meter LED
CH1 Level Meter LED
Master Level Meter R CH LED
Master Level Meter L CH LED
CH4 Level Meter LED
CH3 Level Meter LED
MIC LOW
MIC HI
CH4 HI
CH3 HI
Volume
Lighting LED
Remark
"-12" : Lights off
"+12" : Full Illuminate
"-26" : Lights off
"+6" :
Full
Illuminate
"-26" : Lights off
"+6" :
Full
Illuminate
• group 2
Rotary volume that can be confirmed
• CH1 MID, CH2 MID, CH3 MID, CH4 MID, MASTER LEVEL, FILTER
"-26" :
Lights
off
"+6" :
Full
Illuminate
"-26" :
Lights
off
"+6" :
Full
Illuminate
CH2 MID
CH1 MID
CH2 Level Meter LED
CH1 Level Meter LED
Master Level Meter R CH LED
Master Level Meter L CH LED
CH4 Level Meter LED
CH3 Level Meter LED
FREQUENCY
MASTER LEVEL
CH4 MID
CH3 MID
Volume
Lighting LED
Remark
"LPF" : Lights off
"HPF" : Full Illuminate
"-26" :
Lights
off
"+6" :
Full
Illuminate
"-26" :
Lights
off
"+6" :
Full
Illuminate
VOLTEST
1
VOLTEST
2
VOLTEST
3
BEAT
UP
BEAT
UP
BEAT
DOWN
BEAT
DOWN
VOLTEST
4
BEAT
UP
BEAT
DOWN
"- " : Lights off
"0" :
Full