AVX-MG2037ZF/XN/UC
A
B
C
D
5
6
7
8
5
6
7
8
119
6.7 TOUCH PANEL CALIBRATION
1
2
4
3
1
2
4
3
OK
-
Calibrate the touch panel in the following cases:
• After changing the EEPROM(IC601).
• When the touch screen is out of alignment.
• When the EEPROM(IC601) data is erased.
-
Turning on the Calibration Mode
Press the MAP, DEST and MENU buttons simulataneously turn on the ACC.
-
Calibration
Using the stylus pen, touch the point indicated in each corner of the screen in the order shown. "OK" is displayed at
the top of the screen to indicate that the touch screen has been calibrated, then normal operation will resume.
-
Storing the calibration data
Switch ACC ON to OFF and leave OFF for at least than 10 seconds. During this time, do not switch off the backup
power.
-
Verification
To check the calibration, press "AM", then "Sound" then "Bass/Treble" to select the Audio Adjustment mode, then
press "0" for both "Bass" and "Treble". The button display should be displayed reversed.
Summary of Contents for AVX-MG2037UC
Page 8: ...AVX MG2037ZF XN UC A B C D 1 2 3 4 1 2 3 4 8 2 2 EXTERIOR 1 AVX MG2137ZF ...
Page 10: ...AVX MG2037ZF XN UC A B C D 1 2 3 4 1 2 3 4 10 2 3 EXTERIOR 1 AVX MG2237ZF AVX MG2337ZF ...
Page 12: ...AVX MG2037ZF XN UC A B C D 1 2 3 4 1 2 3 4 12 2 4 EXTERIOR 2 AVX MG2037ZF AVX MG2137ZF ...
Page 14: ...AVX MG2037ZF XN UC A B C D 1 2 3 4 1 2 3 4 14 2 5 EXTERIOR 2 AVX MG2237ZF AVX MG2337ZF ...
Page 23: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 23 ...
Page 37: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 37 ...
Page 51: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 51 ...
Page 55: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 55 A SIDE B OPEN 1 4 2 3 ...
Page 59: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 59 C SIDE B PWRBL ROUT GOUT UT BRIGHT PWR5 GNDBL1 ...
Page 65: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 65 ...
Page 67: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 67 H H CONTROL UNIT G2F SIDE B IC Q ...
Page 125: ...AVX MG2037ZF XN UC A B C D 5 6 7 8 5 6 7 8 125 7 1 2 PCB LOCATIONS ...